Pilot Wave-Mixed Bioreactor
中试摇摆式生物反应器
- SKU PIB-0005
- Pilot Bioreactors
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- ISO 11137 sterilization (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working volume | 10–500 L |
|---|---|
| Mixing principle | Rocking platform, wave induced |
| Rocking angle | 2–12 degrees |
| Rocking speed | 2–30 rocks per minute |
| Temperature range | Ambient +5 to 45 °C |
| Bag material | Multi-layer gas-permeable film |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EU GMP Annex 1, EU GMP Annex 11, 21 CFR Part 11
What is the Pilot Wave-Mixed Bioreactor?
A pilot wave-mixed bioreactor uses a rocking single-use bag to mix and aerate the culture gently, providing low shear at intermediate volumes. It suits shear-sensitive cells, fragile cell types and clinical scale-up.
What is the Pilot Wave-Mixed Bioreactor?
A pilot wave-mixed bioreactor uses a rocking single-use bag to mix and aerate the culture gently, providing low shear at intermediate volumes. It suits shear-sensitive cells, fragile cell types and clinical scale-up.
Overview
A pilot wave-mixed bioreactor scales the rocking-bag principle to intermediate volumes, usually tens to a few hundred litres. A pre-sterilized bag sits on a platform that tilts, creating a wave that washes across the gas-permeable film each cycle and provides both mixing and oxygen transfer. Because there is no impeller and no sparging through the bulk liquid, shear is low, which suits fragile cells such as T cells, stem cells and some insect and plant cells. The rocking angle and speed set the mixing intensity and oxygen transfer, and temperature is controlled by a heating plate or air circulation beneath the platform. The single-use bag avoids cleaning validation, and ports support pH, dissolved oxygen, sampling and feeds. Oxygen transfer is lower than in stirred vessels, so very high densities may need enrichment or a different design.
How does it work?
A pilot bioreactor applies the same biological principles as a smaller vessel but at a scale where mixing, oxygen transfer and heat removal behave differently. Larger impellers and higher gas flow increase oxygen transfer, described by the volumetric mass-transfer coefficient, while a jacket or coil removes the greater metabolic heat load. Sensors for temperature, pH, dissolved oxygen, pressure and often foam or level sit in hygienic fittings, and cascade control adjusts agitation, gas composition and back pressure to hold dissolved oxygen. Because mixing time, tip speed and mass-transfer coefficient cannot all be matched to bench scale, engineers choose the most critical criterion and verify performance during the run. Pilot vessels may be reusable stainless steel or single-use, and they include defined sampling, feed and harvest points.
What are the key features?
- Rocking single-use bag for wave mixing
- Low shear suitable for fragile cells
- Gas exchange through the bag film
- Angle and speed control for mixing intensity
- No cleaning validation of the fluid path
What are the technical specifications?
A typical pilot wave-mixed bioreactor configuration offers working volume of 10–500 L, mixing principle of Rocking platform, wave induced, rocking angle of 2–12 degrees, rocking speed of 2–30 rocks per minute, temperature range of Ambient +5 to 45 °C and bag material of Multi-layer gas-permeable film. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Pilot Wave-Mixed Bioreactor is used in cell therapy clinical production, stem cell expansion, shear-sensitive culture scale-up and multi-product manufacturing. Across the wider Pilot Bioreactors class, laboratories also deploy it for scale-up verification, clinical and trial batch production and monoclonal antibody and protein production.
Which standards and certifications apply?
Relevant standards and methods include EU GMP Annex 1, EU GMP Annex 11, 21 CFR Part 11, 21 CFR Part 211, GB/T 150, ISO 13485, USP <87>, USP <88>, ICH Q11 and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 manufacturing and ISO 11137 sterilization; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Qualify the vessel and its utilities with documented pressure, temperature, cleaning and sterilization tests. Calibrate pH and dissolved oxygen probes before each run and verify sensor placement so readings reflect bulk conditions. Establish the scale-up criterion and document why it was chosen, then record the supporting data. Monitor foam, heat removal and dissolved oxygen closely, since these are the usual scale-dependent problems. Keep batch records that capture setpoints, deviations and offline measurements such as cell count and metabolite levels. For reusable vessels, control cleaning cycles and gaskets; for single-use, manage bag lots, integrity and extractables data. Confirm electrical safety to IEC 61010-1.
How do I select the right Pilot Wave-Mixed Bioreactor?
Choose a pilot wave bioreactor for gentle, low-shear culture of sensitive cells at intermediate volume. In an RFQ specify volume range, rocking angle and speed, bag film and sensor options, temperature control and sampling and feed requirements.
How does it compare with other Pilot Bioreactors variants?
Size the vessel to reproduce the most important bench parameter and to produce enough material for the next step, whether that is a clinical batch, a trial quantity or data for production design. Decide between stainless steel, which suits repeated campaigns and higher pressure, and single-use, which shortens changeover and reduces cleaning validation. Match the geometry, impeller type and gas handling to the scale-up criterion you intend to hold constant. List control loops and ranges, the number of feed, sampling and harvest ports, and whether redox, off-gas analysis or back pressure control are needed. Evaluate clean-in-place and sterilize-in-place for reusable designs, single-use bag performance for disposable designs, and the records and qualification package available for regulated work.
Full specifications
| Working volume | 10–500 L |
|---|---|
| Mixing principle | Rocking platform, wave induced |
| Rocking angle | 2–12 degrees |
| Rocking speed | 2–30 rocks per minute |
| Temperature range | Ambient +5 to 45 °C |
| Bag material | Multi-layer gas-permeable film |
| Sterilization | Gamma irradiation 25–40 kGy |
| Sensors | Single-use pH and dissolved oxygen options |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell therapy clinical production
- Stem cell expansion
- Shear-sensitive culture scale-up
- Multi-product manufacturing
Key features
- Rocking single-use bag for wave mixing
- Low shear suitable for fragile cells
- Gas exchange through the bag film
- Angle and speed control for mixing intensity
- No cleaning validation of the fluid path
Frequently asked questions about Pilot Wave-Mixed Bioreactor
Cell therapy products are living and often fragile, so mechanical stress during mixing can reduce viability and function. Wave mixing keeps shear low while still supplying oxygen and nutrients, which helps preserve the cells through expansion and harvest.
Oxygen enters through the bag film at the liquid surface, so transfer depends on the wave area and speed and on the liquid volume. At high cell densities or large volumes, enrichment or a stirred single-use design may be needed to meet demand.
They cover clinical and intermediate volumes well, but mixing becomes less effective as volume rises because the wave must move the whole liquid mass. Large production volumes generally use stirred single-use or stainless bioreactors instead.
It verifies that a process developed at bench scale behaves as expected at larger volume and it produces enough material for clinical trials, product evaluation or production design. It also reveals scale-dependent effects such as oxygen limitation or poor heat removal.
Constant volumetric mass-transfer coefficient, tip speed, power per volume and mixing time cannot all be held simultaneously. The team selects the criterion most related to product quality or yield, applies it at pilot scale and verifies the result before transferring to production.
Stainless steel suits repeated campaigns, higher pressures and steam sterilization, while single-use suits multi-product or clinical work where cleaning validation between products would be costly. Extractables data, volume and pressure limits and supply continuity guide the single-use choice.
Related models