Vaccine Storage Refrigerator with Data Logging
带数据记录的疫苗冷藏箱
- SKU PHR-0005
- Pharmacy Refrigerators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- WHO PQS E003 listing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 2–8 °C |
|---|---|
| Net volume | 100–700 L |
| Temperature uniformity | ≤ 2.5 K at 5 °C set point |
| Probe type | Glycol-buffered, independent alarm probe |
| Logging interval | 1–15 min, adjustable |
| Data storage | Approx. 3–12 months, USB export |
By Lab Manufacturers China Technical TeamLast reviewed Standards: WHO PQS E003 refrigerators and freezers, WHO Good Distribution Practices for pharmaceutical products (TRS 957 Annex 5), EU GDP Guidelines 2013/C 343/01
What is the Vaccine Storage Refrigerator with Data Logging?
A purpose-built 2–8 °C refrigerator for vaccines, with a buffered probe, continuous electronic data logging and extended hold-over time. It is intended for immunisation clinics, public-health stores and hospital pharmacies that must show temperature compliance over the cold chain.
What is the Vaccine Storage Refrigerator with Data Logging?
A purpose-built 2–8 °C refrigerator for vaccines, with a buffered probe, continuous electronic data logging and extended hold-over time. It is intended for immunisation clinics, public-health stores and hospital pharmacies that must show temperature compliance over the cold chain.
Overview
Vaccine refrigerators are built around tight temperature uniformity and traceable records. A glycol-buffered probe approximates product temperature rather than air temperature, so door openings do not trigger false alarms. The logger records at intervals of 1–15 minutes, stores several months of data, and exports to USB or cloud software. Thick insulation, ice-lined walls or phase-change packs extend hold-over time during a power failure, often to several hours. The cabinet has no freezer compartment or evaporator plate that could freeze vaccines, and the door is lockable. Controllers have independent alarm circuits and battery backup, and remote SMS or email notification is common. Typical volumes range from 100 to 700 L, with both undercounter and upright formats.
How does it work?
A pharmacy refrigerator removes heat from an insulated cabinet with a vapour-compression circuit: a compressor, condenser, expansion device and evaporator circulate refrigerant, typically R600a, R290 or R134a. A fan moves air over the evaporator and through the cabinet, which equalises temperature and speeds recovery after door opening. A microprocessor controller reads an air or buffered probe and cycles the compressor around the set point, normally 5 °C. Independent sensors drive high and low alarms, door-ajar warnings and power-failure alerts. Insulation of polyurethane foam, a sealed door gasket and, in some models, a heated glass door limit heat gain and condensation. Data loggers record temperature for audit. Performance is judged by uniformity, stability, recovery time and hold-over during power loss.
What are the key features?
- Glycol-buffered probe tracks product temperature and limits false alarms
- Continuous data logger with USB or cloud export
- Extended hold-over time during power failure using thick insulation or phase-change packs
- No freezer plate or cold spot that could freeze vaccines
- Independent alarm circuit with battery backup and remote notification
What are the technical specifications?
A typical vaccine storage refrigerator with data logging configuration offers temperature range of 2–8 °C, net volume of 100–700 L, temperature uniformity of ≤ 2.5 K at 5 °C set point, probe type of Glycol-buffered, independent alarm probe, logging interval of 1–15 min, adjustable and data storage of Approx. 3–12 months, USB export. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Vaccine Storage Refrigerator with Data Logging is used in immunisation clinics, public-health vaccine stores, hospital pharmacies and cold-chain distribution points. Across the wider Pharmacy Refrigerators class, laboratories also deploy it for hospital pharmacy stock, vaccine storage and insulin and biologics.
Which standards and certifications apply?
Relevant standards and methods include WHO PQS E003 refrigerators and freezers, WHO Good Distribution Practices for pharmaceutical products (TRS 957 Annex 5), EU GDP Guidelines 2013/C 343/01, USP <1079> Good Storage and Distribution Practices, IEC 61010-1 and ISO 13485. Certification candidates for this model are CE, ISO 9001 manufacturing, ISO 13485 manufacturing and WHO PQS E003 listing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the cabinet on a level floor away from heat sources and direct sunlight, leaving the ventilation clearance in the manual, and let it stabilise for several hours before loading. Validate the cabinet by temperature mapping at empty and loaded conditions, and calibrate probes against a traceable reference at least annually. Clean the condenser every few months, check door gaskets and verify alarms regularly. Keep stock away from the evaporator outlet. Retain temperature records and excursion reports for the period required by your regulator. Good practice guidance, such as WHO and national pharmacy rules, sets expectations for monitoring and response.
How do I select the right Vaccine Storage Refrigerator with Data Logging?
Select this variant when vaccine storage requires continuous records, buffered probes and hold-over time. Specify volume, format, logger export method, required hold-over hours at your ambient temperature and whether WHO PQS-listed performance is required by your programme. Standard pharmacy models suit general medicines with less demanding record requirements.
How does it compare with other Pharmacy Refrigerators variants?
Start from what is stored and how much. Small volumes of routine medicines fit an undercounter unit, typical dispensary stock fits a single-door upright, and central stores need a double-door cabinet. Vaccines call for a dedicated model with buffered probe, data logging and verified hold-over time. Consider uniformity (about 3 K or better), recovery after door opening, alarm set, interface to monitoring systems and door type. Check whether the refrigerant and energy use match local rules, and confirm the ambient temperature range, since a cabinet rated for 32 °C may struggle in a hot storeroom. Combination units suit small sites with frozen items.
Full specifications
| Temperature range | 2–8 °C |
|---|---|
| Net volume | 100–700 L |
| Temperature uniformity | ≤ 2.5 K at 5 °C set point |
| Probe type | Glycol-buffered, independent alarm probe |
| Logging interval | 1–15 min, adjustable |
| Data storage | Approx. 3–12 months, USB export |
| Hold-over time | Approx. 4–12 h at 25 °C ambient, model-dependent |
| Refrigerant | R600a or R290 |
| Notification | Local alarm, SMS/email option |
| Power supply | 220–240 V, 50 Hz with backup battery |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Immunisation clinics
- Public-health vaccine stores
- Hospital pharmacies
- Cold-chain distribution points
Key features
- Glycol-buffered probe tracks product temperature and limits false alarms
- Continuous data logger with USB or cloud export
- Extended hold-over time during power failure using thick insulation or phase-change packs
- No freezer plate or cold spot that could freeze vaccines
- Independent alarm circuit with battery backup and remote notification
Frequently asked questions about Vaccine Storage Refrigerator with Data Logging
A buffered probe sits in a glycol-filled vial, so it responds slowly and reports a temperature close to that of the vaccine itself. It avoids false alarms from brief door openings while still detecting sustained excursions that could damage the product.
Hold-over depends on insulation, ambient temperature and load. Many vaccine-specific cabinets hold 2–8 °C for several hours at 25 °C ambient, and some for longer. Ask the manufacturer for test data and verify on site.
Retention is set by national immunisation programmes and local regulation, commonly at least three years. Logger data should be exported regularly to secure storage, and any excursions should be documented with the action taken and the decision on product use.
A pharmacy refrigerator is a cabinet that holds medicines, biologicals and vaccines at 2–8 °C. It differs from a domestic refrigerator by using forced-air circulation, calibrated controllers, alarms and optional data logging so stock stays within labelled limits and compliance can be shown.
Domestic refrigerators are not recommended for vaccines and sensitive medicines, because their temperature swings are wider and they lack alarms and records. Some can freeze items near the back wall. Use a purpose-built pharmacy refrigerator for regulated stock.
Most refrigerated medicines are labelled for 2–8 °C, so the cabinet is normally set near 5 °C to leave margin on both sides. Always check the labelled storage condition of each product, since a few products have narrower or different ranges.