UV Sterilizing PCR Cabinet
紫外灭菌 PCR 柜
- SKU PCC-0003
- PCR Cabinets
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Type | UV sterilizing PCR cabinet |
|---|---|
| UV lamps | 1–2 × 254 nm |
| UV intensity | ≥ 70 µW/cm2 at 1 m |
| Timer range | 0–99 min |
| Interlock | Door open, UV off |
| Interior | Reflective stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), EN 1822 (HEPA and ULPA filters)
What is the UV Sterilizing PCR Cabinet?
A UV sterilizing PCR cabinet emphasises timed ultraviolet decontamination of the work zone alongside a contained front. It suits laboratories where surface decontamination between reactions is the main control for carry-over contamination.
What is the UV Sterilizing PCR Cabinet?
A UV sterilizing PCR cabinet emphasises timed ultraviolet decontamination of the work zone alongside a contained front. It suits laboratories where surface decontamination between reactions is the main control for carry-over contamination.
Overview
This cabinet provides a larger internal UV treatment volume than a standard workstation, with one or two 254 nm lamps, a programmable timer and a door interlock. Some models include a HEPA recirculation option, but the emphasis is on UV decontamination of surfaces and the enclosed space between sessions, so the effect is strongest on exposed surfaces that receive direct light. Interior reflectors and white-lined walls improve coverage, and a stainless work surface resists repeated wiping. The front may be a full or partial panel, and lighting for pipetting is separate from the UV lamp. The lamp output is specified in µW/cm2 at a distance, and users should check lamps with a meter and replace them at end of life. Cleaning with a validated decontaminant remains the primary step, with UV as a supplement.
How does it work?
A PCR cabinet reduces the chance that stray DNA or RNA contaminates a reaction or that amplified product carries over into the next sample. Two mechanisms are used. A laminar flow PCR cabinet passes HEPA-filtered air across the work surface at 0.3–0.5 m/s, sweeping particles and aerosols away, and gives ISO 5 cleanliness at the work point. A dead-air or still-air workstation instead encloses the work but does not supply filtered air, relying on limited air exchange, UV irradiation and careful technique to reduce contamination. Both types usually include a 254 nm UV lamp for surface decontamination between sessions, and many include a timer and an interlock so that UV cannot run while the sash is open. Some models are ducted for vapour removal. Regular cleaning, separate pre- and post-PCR areas and dedicated equipment remain essential.
What are the key features?
- One or two 254 nm UV lamps for the chamber
- Programmable timer and door interlock
- Reflective interior for better UV coverage
- Stainless work surface for wiping
- Separate white or blue work lighting
- Optional HEPA recirculation
What are the technical specifications?
A typical uv sterilizing pcr cabinet configuration offers type of UV sterilizing PCR cabinet, UV lamps of 1–2 × 254 nm, UV intensity of ≥ 70 µW/cm2 at 1 m, timer range of 0–99 min, interlock of Door open, UV off and interior of Reflective stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The UV Sterilizing PCR Cabinet is used in reaction set-up with UV cycles, diagnostic molecular work, forensic sample preparation and contamination-sensitive assays. Across the wider PCR Cabinets class, laboratories also deploy it for PCR reaction set-up, nucleic acid extraction and handling and molecular diagnostics.
Which standards and certifications apply?
Relevant standards and methods include ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), EN 1822 (HEPA and ULPA filters), IEST-RP-CC002 (unidirectional flow clean-air devices), ISO 15190 (medical laboratories, safety requirements) and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the cabinet in the pre-PCR area for reaction set-up and keep a separate area for post-PCR work, using dedicated pipettes and consumables. Clean the work surface with a validated decontaminant before and after each session, and run the UV lamp for the set period, ensuring the sash interlock prevents exposure. Replace the UV lamp at the end of its rated life, since output falls before total failure, and check lamps with a meter if available. For HEPA models, verify filter integrity and face velocity at installation and at least annually, and change prefilters as specified. Do not use the cabinet for hazardous aerosols or chemical vapour, and keep airflow free of draughts by siting it away from doors.
How do I select the right UV Sterilizing PCR Cabinet?
Choose this cabinet when surface decontamination between reactions is the main control and a larger UV-treated volume is useful. Confirm lamp intensity, timer range and interlock. RFQ: UV intensity, lamp count, timer, HEPA option, width and lighting.
How does it compare with other PCR Cabinets variants?
Choose a HEPA laminar flow PCR cabinet when the work needs a clean air zone over the samples, for example when preparing reactions from low-copy templates. Choose a dead-air or still-air workstation when the priority is physical isolation and UV decontamination rather than particle removal. Confirm that the UV lamp, timer and sash interlock suit the decontamination procedure, and that the internal height and footprint fit pipettes, racks and a small centrifuge. Decide whether the cabinet recirculates or is ducted, and whether a white light or blue light option is needed. For regulated diagnostics, check that the cabinet supports the workflow and cleaning validation, and verify filter performance where HEPA is fitted. Good laboratory layout with separate pre- and post-PCR zones matters as much as the cabinet itself.
Full specifications
| Type | UV sterilizing PCR cabinet |
|---|---|
| UV lamps | 1–2 × 254 nm |
| UV intensity | ≥ 70 µW/cm2 at 1 m |
| Timer range | 0–99 min |
| Interlock | Door open, UV off |
| Interior | Reflective stainless steel |
| HEPA option | Optional recirculation |
| Width | 600–1200 mm |
| Lighting | White or blue LED |
| Power supply | 220 V, 50 Hz, 60–200 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reaction set-up with UV cycles
- Diagnostic molecular work
- Forensic sample preparation
- Contamination-sensitive assays
Key features
- One or two 254 nm UV lamps for the chamber
- Programmable timer and door interlock
- Reflective interior for better UV coverage
- Stainless work surface for wiping
- Separate white or blue work lighting
- Optional HEPA recirculation
Frequently asked questions about UV Sterilizing PCR Cabinet
In µW/cm2 at a stated distance, commonly 1 m. Because intensity falls with distance and lamp age, check the lamp with a meter and replace it when output drops below the working value.
No. UV is absorbed by plastic and only treats exposed surfaces. Tubes, tips and racks must be handled and discarded so that surfaces are not the source of carry-over contamination.
Not always. UV treats surfaces while HEPA recirculation reduces airborne particles, so add the HEPA option when a clean air supply over samples is also required, such as low-copy work.
It is used to set up PCR and handle nucleic acids in a small enclosed area that reduces contamination and sample cross-over. Many models add UV and HEPA filtration for cleaner working conditions.
Choose HEPA laminar flow when a clean air zone over the samples is needed, such as low-copy template work. A dead-air box suits work where physical isolation and UV decontamination matter more than particle removal.
Commonly 15–30 minutes between sessions, following the manufacturer's guidance and a validated decontamination procedure. UV is a supplement to cleaning, not a replacement, and the lamp output falls over its life.