Dead-Air PCR Workstation

静滞空气 PCR 工作站

  • SKU PCC-0001
  • PCR Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
TypeDead-air PCR workstation
Air supplyNone, still air
UV lamp254 nm, timed
UV interlockPanel open, UV off
Width500–900 mm
Depth400–600 mm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), EN 1822 (HEPA and ULPA filters)

What is the Dead-Air PCR Workstation?

A dead-air PCR workstation encloses reaction set-up in a still-air box with UV decontamination. It is used where physical isolation and surface decontamination matter more than filtered airflow as the main control.

What is the Dead-Air PCR Workstation?

A dead-air PCR workstation encloses reaction set-up in a still-air box with UV decontamination. It is used where physical isolation and surface decontamination matter more than filtered airflow as the main control.

Overview

The workstation is a small enclosure, typically 500–900 mm wide and 400–600 mm deep, with a hinged or sliding panel and a stainless or plastic-lined interior. It does not supply filtered air; instead, limited air exchange within the closed box keeps external particles and drafts away from the reaction mix. A 254 nm UV lamp decontaminates surfaces between sessions, controlled by a timer and interlocked with the front panel so UV cannot run while it is open. Interior white or blue lighting aids pipetting, and a small shelf or rack holds tubes. The design is simple, quiet and low-cost, and suits diagnostic and research laboratories handling routine reactions, provided that cleaning and good technique are followed and distinct pre- and post-PCR areas are used.

How does it work?

A PCR cabinet reduces the chance that stray DNA or RNA contaminates a reaction or that amplified product carries over into the next sample. Two mechanisms are used. A laminar flow PCR cabinet passes HEPA-filtered air across the work surface at 0.3–0.5 m/s, sweeping particles and aerosols away, and gives ISO 5 cleanliness at the work point. A dead-air or still-air workstation instead encloses the work but does not supply filtered air, relying on limited air exchange, UV irradiation and careful technique to reduce contamination. Both types usually include a 254 nm UV lamp for surface decontamination between sessions, and many include a timer and an interlock so that UV cannot run while the sash is open. Some models are ducted for vapour removal. Regular cleaning, separate pre- and post-PCR areas and dedicated equipment remain essential.

What are the key features?

  • Enclosed still-air work box
  • 254 nm UV lamp with timer and interlock
  • White or blue interior lighting
  • Widths 500–900 mm with shelf or rack
  • Stainless or plastic-lined interior
  • Simple quiet operation, no filter

What are the technical specifications?

A typical dead-air pcr workstation configuration offers type of Dead-air PCR workstation, air supply of None, still air, UV lamp of 254 nm, timed, UV interlock of Panel open, UV off, width of 500–900 mm and depth of 400–600 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dead-Air PCR Workstation is used in routine PCR set-up, diagnostic molecular work, teaching laboratories and sample preparation. Across the wider PCR Cabinets class, laboratories also deploy it for PCR reaction set-up, nucleic acid extraction and handling and molecular diagnostics.

Which standards and certifications apply?

Relevant standards and methods include ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), EN 1822 (HEPA and ULPA filters), IEST-RP-CC002 (unidirectional flow clean-air devices), ISO 15190 (medical laboratories, safety requirements) and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the cabinet in the pre-PCR area for reaction set-up and keep a separate area for post-PCR work, using dedicated pipettes and consumables. Clean the work surface with a validated decontaminant before and after each session, and run the UV lamp for the set period, ensuring the sash interlock prevents exposure. Replace the UV lamp at the end of its rated life, since output falls before total failure, and check lamps with a meter if available. For HEPA models, verify filter integrity and face velocity at installation and at least annually, and change prefilters as specified. Do not use the cabinet for hazardous aerosols or chemical vapour, and keep airflow free of draughts by siting it away from doors.

How do I select the right Dead-Air PCR Workstation?

Choose a dead-air box when the priority is physical isolation and UV decontamination at low cost. Confirm the interior size fits racks and pipettes. RFQ: width, depth, UV timer setting, lighting colour and power supply required.

How does it compare with other PCR Cabinets variants?

Choose a HEPA laminar flow PCR cabinet when the work needs a clean air zone over the samples, for example when preparing reactions from low-copy templates. Choose a dead-air or still-air workstation when the priority is physical isolation and UV decontamination rather than particle removal. Confirm that the UV lamp, timer and sash interlock suit the decontamination procedure, and that the internal height and footprint fit pipettes, racks and a small centrifuge. Decide whether the cabinet recirculates or is ducted, and whether a white light or blue light option is needed. For regulated diagnostics, check that the cabinet supports the workflow and cleaning validation, and verify filter performance where HEPA is fitted. Good laboratory layout with separate pre- and post-PCR zones matters as much as the cabinet itself.

Full specifications

Full specifications
TypeDead-air PCR workstation
Air supplyNone, still air
UV lamp254 nm, timed
UV interlockPanel open, UV off
Width500–900 mm
Depth400–600 mm
InteriorStainless or PP lined
LightingWhite or blue LED
Noise level≤ 45 dB(A)
Power supply220 V, 50 Hz, 50–150 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine PCR set-up
  • Diagnostic molecular work
  • Teaching laboratories
  • Sample preparation

Key features

  • Enclosed still-air work box
  • 254 nm UV lamp with timer and interlock
  • White or blue interior lighting
  • Widths 500–900 mm with shelf or rack
  • Stainless or plastic-lined interior
  • Simple quiet operation, no filter

Frequently asked questions about Dead-Air PCR Workstation

No. It encloses the work in still air, so external particles and drafts are limited by the closed box rather than a filter. Add a HEPA laminar flow model if a clean air supply over the samples is required.

Related models

All PCR Cabinets

Request a quotation for the Dead-Air PCR Workstation