Water-Washdown Perchloric Acid Hood — product photo

Water-Washdown Perchloric Acid Hood

水冲洗高氯酸通风柜

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Body materialPolypropylene, PVC or stainless steel
Washdown coverageInterior, baffles and full duct
Washdown cycle3–10 min, timer controlled
Face velocity0.4–0.6 m/s
Airflow600–1500 m3/h
Width1200–1800 mm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14175-2 (fume cupboards, safety and performance), EN 14175-3 (type test methods), ASHRAE 110 (method of testing performance of laboratory fume hoods)

What is the Water-Washdown Perchloric Acid Hood?

A water-washdown perchloric acid hood floods the interior and full duct with water on a timed cycle to dissolve perchlorate deposits. It is the baseline design for any perchloric acid digestion application.

What is the Water-Washdown Perchloric Acid Hood?

A water-washdown perchloric acid hood floods the interior and full duct with water on a timed cycle to dissolve perchlorate deposits. It is the baseline design for any perchloric acid digestion application.

Overview

The hood is built with a smooth, non-combustible liner and an all-welded duct that has no horizontal runs or ledges where salt could settle. A spray manifold wets the back baffle, side walls and work surface, and nozzles fitted inside the duct wash its full length during each cycle. Washdown runs for 3–10 minutes, controlled by a timer or manual switch, and drains through an acid-resistant trap to a dedicated waste line. Face velocity is held at 0.4–0.6 m/s, and airflow, washdown status and alarms are shown on a control panel. Construction uses polypropylene, PVC or stainless steel with coved corners and no exposed fasteners. The dedicated exhaust fan is corrosion-resistant and sized for the duct plus washdown spray resistance.

How does it work?

Perchloric acid hoods work like other fume hoods but add a washdown system that periodically sprays water through the interior, the rear baffle and the entire exhaust duct. Heated perchloric acid vaporises, and its vapour can condense with organic material to form perchlorate salts in the duct, which are shock-sensitive and can explode. Water washdown dissolves these deposits before they accumulate. The hood and duct are constructed from non-combustible, chemically resistant materials with smooth, coved and crevice-free interiors and no sharp bends or horizontal runs where liquid or salt could collect. The washdown cycle runs for several minutes, typically daily or after each use, and drains to a dedicated chemical waste line. A dedicated exhaust system, separate from other hoods, prevents cross contamination and dilution problems.

What are the key features?

  • Full washdown of liner, baffles and duct
  • All-welded duct with no horizontal runs
  • Washdown cycle 3–10 minutes, timer controlled
  • Coved corners and no exposed fasteners
  • Dedicated corrosion-resistant exhaust fan
  • Face velocity 0.4–0.6 m/s with alarm

What are the technical specifications?

A typical water-washdown perchloric acid hood configuration offers body material of Polypropylene, PVC or stainless steel, washdown coverage of Interior, baffles and full duct, washdown cycle of 3–10 min, timer controlled, face velocity of 0.4–0.6 m/s, airflow of 600–1500 m3/h and width of 1200–1800 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Water-Washdown Perchloric Acid Hood is used in perchloric acid digestion, trace-metal sample preparation, environmental analysis and food and biological decomposition. Across the wider Perchloric Acid Hoods class, laboratories also deploy it for trace-metal digestion with perchloric acid, environmental and geological analysis and food and biological sample decomposition.

Which standards and certifications apply?

Relevant standards and methods include EN 14175-2 (fume cupboards, safety and performance), EN 14175-3 (type test methods), ASHRAE 110 (method of testing performance of laboratory fume hoods), NFPA 45 (fire protection for laboratories using chemicals), GB/T 34269 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Never share the duct with other hoods, and never use the hood for organic solvents or for drying organic material, since perchloric acid and organics can form explosive mixtures. Run the washdown cycle before and after work and keep a log of cycles and cleaning. Inspect the duct interior for salt deposits on a defined schedule, using a borescope where needed, and clean any deposit with water rather than scraping. Keep all surfaces smooth and free of ledges, gaskets or insulation that could collect salts. Verify face velocity and alarms regularly, and train users to keep glassware away from baffles. Treat washdown effluent as acidic waste and confirm the trap and drain are compatible.

How do I select the right Water-Washdown Perchloric Acid Hood?

Choose this design for any perchloric acid work as the minimum requirement. Confirm washdown covers the entire duct and that the exhaust is dedicated. RFQ: acid volumes, digestion equipment, duct route and length, drainage location and washdown controls.

How does it compare with other Perchloric Acid Hoods variants?

Every perchloric acid hood must have a full washdown system covering the interior and the whole duct, because partial washdown leaves deposition sites. Choose a dedicated exhaust path with no shared ductwork, and specify smooth, all-welded construction with coved corners and no internal fasteners or ledges. Select the liner for the acids used: polypropylene or PVC for mixed acid work, and stainless steel or special alloys where hot concentrated perchloric acid is handled. Match the internal height to reflux glassware and the digestion block, and select airflow so face velocity stays at 0.4–0.6 m/s. Include a washdown timer or automatic cycle, drainage with an acid-resistant trap, and airflow monitoring with an alarm. Confirm the duct material, slope and washdown coverage in writing.

Full specifications

Full specifications
Body materialPolypropylene, PVC or stainless steel
Washdown coverageInterior, baffles and full duct
Washdown cycle3–10 min, timer controlled
Face velocity0.4–0.6 m/s
Airflow600–1500 m3/h
Width1200–1800 mm
Internal height900–1200 mm
Duct materialAll-welded PP or 316L
DrainageAcid-resistant trap to waste line
FanCorrosion-resistant, dedicated

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Perchloric acid digestion
  • Trace-metal sample preparation
  • Environmental analysis
  • Food and biological decomposition

Key features

  • Full washdown of liner, baffles and duct
  • All-welded duct with no horizontal runs
  • Washdown cycle 3–10 minutes, timer controlled
  • Coved corners and no exposed fasteners
  • Dedicated corrosion-resistant exhaust fan
  • Face velocity 0.4–0.6 m/s with alarm

Frequently asked questions about Water-Washdown Perchloric Acid Hood

It should. A compliant design places nozzles along the duct so every internal surface is wetted each cycle. Partial washdown leaves dry zones where perchlorate salts can accumulate and become hazardous.

Request a quotation for the Water-Washdown Perchloric Acid Hood

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote