Halogen Moisture Analyzer for Paper and Board
纸张和纸板卤素水分测定仪
- SKU MOT-0002
- Moisture Testing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Balance resolution | 1 mg |
|---|---|
| Moisture readability | 0.01% |
| Temperature range | 50–200 °C |
| Drying profiles | Standard, rapid, step and gentle |
| Endpoint criterion | Mass loss per time threshold |
| Typical specimen mass | 3–10 g |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 287, ISO 638, ISO 760
What is the Halogen Moisture Analyzer for Paper and Board?
A halogen moisture analyzer dries a small paper specimen on an integrated balance and reports moisture from the mass loss. It gives results in minutes and is used for routine control where the oven method would be too slow.
What is the Halogen Moisture Analyzer for Paper and Board?
A halogen moisture analyzer dries a small paper specimen on an integrated balance and reports moisture from the mass loss. It gives results in minutes and is used for routine control where the oven method would be too slow.
Overview
The specimen is placed in a disposable pan, weighed automatically and heated by a halogen radiator while the balance monitors mass continuously until the mass loss rate falls below a set threshold. The final value is calculated against either wet or dry mass and displayed as a percentage, together with the drying curve. Because heating conditions differ from an oven, results are not automatically identical: the halogen method may report slightly higher moisture if other volatiles are driven off, so correlation with the oven reference method must be established for each grade and documented as a conversion or offset. Drying temperature, endpoint criterion and specimen mass are the parameters that control the result and should be fixed in the procedure.
How does it work?
All moisture methods compare the mass of water in the sample with either the wet mass or the dry mass, and the chosen reference must always be reported because moisture content and dry matter content give different numbers. The reference method dries a specimen to constant mass in an oven at a specified temperature and calculates the mass loss. Halogen drying performs the same measurement quickly on a built-in balance, using a halogen radiator for faster and more uniform heating, and requires correlation with the oven method for each paper grade. Karl Fischer titration is a chemical method: iodine reacts quantitatively with water, and the endpoint is detected electrochemically, so it measures water specifically and is unaffected by other volatile substances. Microwave and near-infrared instruments measure indirectly through absorption or dielectric response and need calibration against a reference method.
What are the key features?
- Integrated balance with 1 mg resolution
- Halogen radiator for rapid heating
- Programmable drying temperature and endpoint
- Drying curve display and storage
- Wet or dry basis result selection
- Correlation offset with the oven method
What are the technical specifications?
A typical halogen moisture analyzer for paper and board configuration offers balance resolution of 1 mg, moisture readability of 0.01%, temperature range of 50–200 °C, drying profiles of Standard, rapid, step and gentle, endpoint criterion of Mass loss per time threshold and typical specimen mass of 3–10 g. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Halogen Moisture Analyzer for Paper and Board is used in routine moisture control in paper mills, converting shop verification before printing, coated board moisture checks and incoming verification when the oven method is too slow. Across the wider Moisture Testing class, laboratories also deploy it for incoming moisture checks on pulp and recovered paper, machine-direction moisture control during papermaking and finishing and converting moisture verification.
Which standards and certifications apply?
Relevant standards and methods include ISO 287, ISO 638, ISO 760, TAPPI T412, ASTM D644, ASTM D6869 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sample handling dominates the uncertainty because paper equilibrates with the surrounding air within minutes. Cut sealed specimens, weigh them quickly in a closed container, and record the temperature and relative humidity of the laboratory, since the standard equilibrium condition defines the moisture of a well-conditioned sheet. Oven temperature, drying time and the use of a desiccator before weighing must follow the method, and the balance should be checked with certified masses. For indirect instruments, recalibrate whenever furnish, coating, grade or basis weight changes, and keep the reference results used to build the calibration. Store paper samples away from heat and direct sunlight before testing.
How do I select the right Halogen Moisture Analyzer for Paper and Board?
Choose a halogen analyzer for routine control where a result in minutes is required, and confirm that the drying temperature and endpoint settings have been correlated with the oven method for each grade. Check the readability against the tolerance of your specification, since thin papers with a narrow moisture window need the better of the available models.
How does it compare with other Moisture Testing variants?
Choose the reference oven method when a specification value is required, since almost all paper moisture standards are written around it. Select a halogen instrument for routine control where speed matters, but establish and document the correlation with the oven method for each grade, including for coated and highly filled papers. Karl Fischer titration suits samples where volatile substances other than water are present, such as papers containing solvents, and can be combined with an oven accessory for solid samples that do not disperse. Microwave and near-infrared instruments are chosen for production use: the near-infrared systems mount on the machine and measure across the full web width continuously, while microwave instruments suit bale and stack checking on the floor.
Full specifications
| Balance resolution | 1 mg |
|---|---|
| Moisture readability | 0.01% |
| Temperature range | 50–200 °C |
| Drying profiles | Standard, rapid, step and gentle |
| Endpoint criterion | Mass loss per time threshold |
| Typical specimen mass | 3–10 g |
| Typical drying time | 3–10 min |
| Data output | Drying curve and result print or export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine moisture control in paper mills
- Converting shop verification before printing
- Coated board moisture checks
- Incoming verification when the oven method is too slow
Key features
- Integrated balance with 1 mg resolution
- Halogen radiator for rapid heating
- Programmable drying temperature and endpoint
- Drying curve display and storage
- Wet or dry basis result selection
- Correlation offset with the oven method
Frequently asked questions about Halogen Moisture Analyzer for Paper and Board
Not automatically. The halogen method heats the specimen quickly from above while an oven uses circulating hot air for a longer period, and any volatile substances other than water are also driven off in both cases. A grade-specific correlation must therefore be established, with an offset or factor documented.
The instrument stops when the mass loss per unit time falls below a set threshold for a defined period, or after a fixed time. A threshold that is too loose leaves residual moisture, while one that is too tight extends the test unnecessarily, so the setting should be fixed and verified against oven results.
Coated, recycled and highly filled grades, because they contain mineral components, coatings and additives that may release volatiles during heating. Lightweight papers also need attention, since a small absolute mass loss represents a large percentage of a thin sheet.
Moisture content expresses the mass of water as a percentage of the wet specimen, while dry matter content expresses the dry residue as a percentage of the wet specimen, so the two do not add to 100 in the usual sense. Standards state which basis applies, and results from the two bases must never be mixed in one specification.
Electrical and near-infrared instruments respond to the interaction of water with the fibre, filler and coating, so a calibration built on one furnish does not transfer to another. Each grade, coating type and basis weight range needs its own correlation, and the calibration should be rechecked after any change in raw materials.
Cut specimens from the sheet and place them immediately into a closed container or sealed bag, then transfer them to a weighing bottle or drying vessel with minimal exposure. Handling time, ambient conditions and the container used all affect the result, so they should be standardised and recorded in the procedure.