Automated High-Throughput Genotyping Platform
自动化高通量基因分型平台
- SKU GES-0005
- Genotyping Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Plate formats | 384-well and 1,536-well |
|---|---|
| Data points per day | approx. 5,000–40,000 (assay dependent) |
| Pipetting volume range | 0.5–50 µL |
| Pipetting accuracy | within ±3% at 5 µL (typical) |
| Throughput per run | up to 1,536 reactions |
| Run time | approx. 40–120 min per plate |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 15189, CLSI MM01
What is the Automated High-Throughput Genotyping Platform?
An automated high-throughput genotyping platform integrates liquid handling, PCR set-up and detection so that thousands of samples are genotyped per day with minimal operator intervention. It suits breeding programmes, seed testing laboratories and screening facilities with continuous sample flow.
What is the Automated High-Throughput Genotyping Platform?
An automated high-throughput genotyping platform integrates liquid handling, PCR set-up and detection so that thousands of samples are genotyped per day with minimal operator intervention. It suits breeding programmes, seed testing laboratories and screening facilities with continuous sample flow.
Overview
The platform consists of a robotic liquid handler that transfers DNA and master mix into 384-well or 1,536-well plates, a fast thermocycler with fluorescence detection, and software that links plate barcodes to sample records and calls genotypes automatically. Depending on configuration it performs allele-specific PCR, end-point fluorescence reading or high-resolution melt analysis. Throughput reaches several thousand to tens of thousands of data points per day when plates run back-to-back, and barcode-driven workflows keep sample identity intact across pooling and dilution steps. Instrument set-up includes deck configuration, pipetting verification and fluidics checks. Laboratories adopting automation should first validate the complete workflow against their existing manual method, including DNA extraction, because errors in the upstream steps are amplified at plate scale.
How does it work?
Genotyping always compares a measured signal with a known allele pattern. Allele-specific real-time PCR uses two probes labelled with different fluorophores that match each allele, and the ratio of signal from the two channels, plotted against a reference, classifies the sample as homozygous, heterozygous or no call. SNP arrays work by hybridising fragmented, amplified DNA to immobilised probes and reading fluorescence intensity for each allele. Capillary fragment analysis amplifies short tandem repeats or microsatellites and sizes the products, so allele lengths are scored from the electropherogram. Targeted sequencing reads the variant positions directly, which allows discovery of unexpected variants and detection of low-frequency alleles. Across all methods, the quality metrics of cluster separation or coverage depth determine which calls are accepted, and laboratories usually include positive and negative controls in each batch.
What are the key features?
- Robotic plate set-up into 384-well and 1,536-well formats
- Fast thermocycling with integrated fluorescence detection
- Barcode-driven sample tracking from DNA plate to result
- Automated genotype calling with quality flags
- Back-to-back plate scheduling for continuous operation
- Optional high-resolution melt module for probe-free assays
What are the technical specifications?
A typical automated high-throughput genotyping platform configuration offers plate formats of 384-well and 1,536-well, data points per day of approx. 5,000–40,000 (assay dependent), pipetting volume range of 0.5–50 µL, pipetting accuracy of within ±3% at 5 µL (typical), throughput per run of up to 1,536 reactions and run time of approx. 40–120 min per plate. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated High-Throughput Genotyping Platform is used in marker-assisted breeding at population scale, seed purity and variety testing programmes, large-scale germplasm screening and routine animal genotyping in breeding schemes. Across the wider Genotyping Systems class, laboratories also deploy it for clinical variant and pharmacogenomic testing, crop and livestock marker-assisted selection and cell line authentication and STR profiling.
Which standards and certifications apply?
Relevant standards and methods include ISO 20395, ISO 15189, CLSI MM01, ISO 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Genotyping results depend heavily on DNA quality, so extract samples with a consistent method and check concentration and purity before starting. Real-time PCR genotyping needs validated primers and probes and a thermocycler with calibrated optics; arrays and sequencers need controlled temperature and humidity plus a scanner with consistent gain settings. Run positive controls for each genotype and a no-template control in every batch, and re-run ambiguous calls on an independent method rather than re-reading the same data. Cell line authentication should be repeated whenever a line is re-established or a stock is replaced. In clinical use, genotyping assays fall under ISO 15189 and require documented validation of limit of detection, precision and specificity for each reported genotype.
How do I select the right Automated High-Throughput Genotyping Platform?
Select an automated platform when sample volume is sustained and manual plate set-up has become the bottleneck, and be sure the upstream DNA extraction can keep pace. Specify plate formats, throughput, pipetting accuracy, detection channels, barcode tracking, software validation features and service support terms.
How does it compare with other Genotyping Systems variants?
Start with the number of variants and samples. If you score a few known markers in many samples, real-time PCR with allele-specific probes gives the lowest cost per data point and a simple workflow. For hundreds of thousands of markers across a population, arrays provide the highest call rate per sample but need a scanner, and custom arrays have long lead times. Capillary fragment analysis remains the reference for short tandem repeat markers in cell line authentication, forensic work and plant breeding. Targeted sequencing suits panels where you want both known and unexpected variants, or where alleles occur at low frequency in mixed samples. Check multiplexing limits, DNA input, turnaround time, analysis software, genotype-calling algorithm transparency and the ability to re-analyse raw data under your own rules.
Full specifications
| Plate formats | 384-well and 1,536-well |
|---|---|
| Data points per day | approx. 5,000–40,000 (assay dependent) |
| Pipetting volume range | 0.5–50 µL |
| Pipetting accuracy | within ±3% at 5 µL (typical) |
| Throughput per run | up to 1,536 reactions |
| Run time | approx. 40–120 min per plate |
| Detection | Fluorescence with 4–6 filter channels |
| DNA input | 1–20 ng per reaction |
| Trackability | Barcode scanning with audit trail |
| Dimensions (W x D x H) | approx. 1,500 x 900 x 1,000 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Marker-assisted breeding at population scale
- Seed purity and variety testing programmes
- Large-scale germplasm screening
- Routine animal genotyping in breeding schemes
Key features
- Robotic plate set-up into 384-well and 1,536-well formats
- Fast thermocycling with integrated fluorescence detection
- Barcode-driven sample tracking from DNA plate to result
- Automated genotype calling with quality flags
- Back-to-back plate scheduling for continuous operation
- Optional high-resolution melt module for probe-free assays
Frequently asked questions about Automated High-Throughput Genotyping Platform
Realistic output is 5,000–40,000 data points per day, depending on assay time, plate format and how much of the workflow is automated. Extraction capacity and operator review time, not the instrument, usually set the ceiling.
No. Many laboratories automate PCR set-up and detection first, then extend automation upstream as volumes grow. Each step should be validated separately so that a failure can be traced to one part of the workflow.
Sample tracking and upstream DNA quality, not the detection chemistry. Barcode scanning at every plate transfer, control wells on each plate and periodic audits of the sample-to-result chain prevent the plate-scale errors that automation can otherwise propagate.
Genotyping determines which alleles a sample carries at selected positions. Uses include clinical diagnosis of inherited conditions, pharmacogenomic guidance, crop and livestock breeding selection, cell line authentication, microbial strain typing and seed variety verification.
Real-time PCR assays typically multiplex 1–6 markers per reaction but can be run in 384-well plates for thousands of data points per day. Arrays score from a few thousand to several million markers per sample, while targeted panels cover tens to thousands of loci.
A no-call is a sample the calling algorithm cannot classify, usually because DNA quality is poor, the signal falls outside cluster boundaries or an unexpected variant affects the probe. Re-extract or re-quantify the sample and repeat, or confirm by sequencing.