

Headspace GC-MS System
顶空气质联用仪
- SKU GCM-0004
- GC-MS
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Vial capacity | 10, 20 or 22 mL; 12–120 positions |
|---|---|
| Oven temperature range | ambient +10 to 300 °C |
| Transfer line temperature | up to 250 °C |
| Injection precision (RSD) | ≤ 3% |
| Carryover | ≤ 0.05% |
| Mass range (MS) | m/z 1.6–1050 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA Method 8270, EPA Method 524.2, EPA Method 8260
What is the Headspace GC-MS System?
A headspace GC-MS combines an automated headspace sampler with a GC-MS so that volatile compounds are analyzed from the vapor phase above a sample. It avoids injecting non-volatile matrix and is used for residual solvents, blood alcohol, off-odors and volatile impurities in solids and liquids.
What is the Headspace GC-MS System?
A headspace GC-MS combines an automated headspace sampler with a GC-MS so that volatile compounds are analyzed from the vapor phase above a sample. It avoids injecting non-volatile matrix and is used for residual solvents, blood alcohol, off-odors and volatile impurities in solids and liquids.
Overview
A headspace GC-MS sample is sealed in a 10, 20 or 22 mL vial, heated at a set temperature, typically 40 to 200 °C, and allowed to reach equilibrium between liquid or solid and gas phases. An aliquot of vapor is then transferred through a heated transfer line by pressurized loop or syringe injection into the GC inlet. Since the matrix stays in the vial, inlet liners and columns stay cleaner and maintenance intervals lengthen. Mass spectrometric detection adds identification power over flame ionization detection, making it possible to confirm residual solvents and unknown off-odors. Dynamic headspace or trap-based variants increase sensitivity for ultra-trace volatiles. Precision depends on temperature control and vial sealing, with relative standard deviation below 2 to 5 percent expected in routine use. Headspace sampling cannot analyze semi-volatile or non-volatile compounds.
How does it work?
In GC-MS, a liquid or gas sample is vaporized in a heated inlet and carried by helium or hydrogen through a capillary column, typically 15 to 60 m long with a 0.25 mm internal diameter. Compounds separate according to boiling point and interaction with the stationary phase and elute at characteristic retention times. The column exit feeds an ion source, most often electron ionization at 70 eV, which produces reproducible fragmentation patterns that can be matched against libraries such as NIST. Ions are filtered by a mass analyzer, commonly a quadrupole, and counted by an electron multiplier. Acquisition can run in full scan for identification or selected ion monitoring for higher sensitivity. A turbomolecular pump maintains the high vacuum required in the analyzer.
What are the key features?
- Automated heated-oven headspace sampler with 12 to 120 vial capacity and agitation
- Pressure-balanced or loop injection giving relative standard deviation below 3 percent
- Inert heated transfer line minimizing carryover and analyte adsorption
- Optional trap concentration for dynamic headspace at sub-ppb levels
- Mass-selective detection confirming residual solvents and unknown volatile peaks
- Software templates for USP residual solvent and blood alcohol methods
What are the technical specifications?
A typical headspace gc-ms system configuration offers vial capacity of 10, 20 or 22 mL; 12–120 positions, oven temperature range of ambient +10 to 300 °C, transfer line temperature of up to 250 °C, injection precision (RSD) of ≤ 3%, carryover of ≤ 0.05% and mass range (MS) of m/z 1.6–1050. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Headspace GC-MS System is used in residual solvents in pharmaceuticals, blood alcohol and volatile toxicology, off-odor analysis in packaging and plastics, volatile organics in soil and water and volatile impurities in cosmetics and consumer goods. Across the wider GC-MS class, laboratories also deploy it for environmental VOC and semi-volatile analysis, pesticide residue testing in food and forensic toxicology and drug screening.
Which standards and certifications apply?
Relevant standards and methods include EPA Method 8270, EPA Method 524.2, EPA Method 8260, ASTM D5769, USP <467> Residual Solvents, ISO 11423, EN 15662, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the GC-MS on a level bench with a dedicated power outlet, a vented exhaust for the rotary pump, and stable room temperature. Use high-purity carrier gas of at least 99.999 percent with moisture and oxygen traps, since contamination shortens column and filament life. Perform an autotune with perfluorotributylamine before each batch and verify mass accuracy and isotope ratios. Routine maintenance includes replacing inlet liners, septa and gold seals, trimming the column, cleaning the ion source and changing pump oil. Keep leak checks in the daily routine, as air peaks at m/z 28 and 32 indicate a leak. Regulated laboratories should require audit trails, electronic signatures and access control that support 21 CFR Part 11.
How do I select the right Headspace GC-MS System?
Select headspace GC-MS for volatile analytes in dirty, solid or viscous matrices where direct injection would foul the system. Choose pyrolysis or thermal desorption for semi-volatile or polymer samples. In an RFQ, specify vial size, oven range, injection mode, carryover, and whether USP residual solvent or blood alcohol methods must be supported.
How does it compare with other GC-MS variants?
Select a GC-MS by matching the detector to the task. A single quadrupole is the economical choice for routine identification and quantitation of residues, volatiles and unknowns using library matching. A triple quadrupole configuration is needed when matrix interference limits sensitivity, as in pesticide multi-residue or dioxin-related work. Time-of-flight offers fast acquisition and accurate mass for non-targeted screening. Headspace and pyrolysis configurations suit specific sample types without solvent extraction. Check the scan speed, mass range, source cleanliness tolerance, and whether the ion source can be changed without venting. Verify support for helium alternatives such as hydrogen, autosampler capacity, and library and data-integrity software. Ask vendors for detection-limit data, such as octafluoronaphthalene instrument detection limit, measured on the exact configuration quoted.
Full specifications
| Vial capacity | 10, 20 or 22 mL; 12–120 positions |
|---|---|
| Oven temperature range | ambient +10 to 300 °C |
| Transfer line temperature | up to 250 °C |
| Injection precision (RSD) | ≤ 3% |
| Carryover | ≤ 0.05% |
| Mass range (MS) | m/z 1.6–1050 |
| Scan speed (MS) | up to 10000 Da/s |
| Detection limit (ethanol in water) | ≤ 0.5 mg/L (typical) |
| Equilibration time | 1–60 min programmable |
| Carrier gas | Helium or hydrogen, 99.999% |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Residual solvents in pharmaceuticals
- Blood alcohol and volatile toxicology
- Off-odor analysis in packaging and plastics
- Volatile organics in soil and water
- Volatile impurities in cosmetics and consumer goods
Key features
- Automated heated-oven headspace sampler with 12 to 120 vial capacity and agitation
- Pressure-balanced or loop injection giving relative standard deviation below 3 percent
- Inert heated transfer line minimizing carryover and analyte adsorption
- Optional trap concentration for dynamic headspace at sub-ppb levels
- Mass-selective detection confirming residual solvents and unknown volatile peaks
- Software templates for USP residual solvent and blood alcohol methods
Frequently asked questions about Headspace GC-MS System
Headspace sampling analyzes the vapor above a heated, sealed sample instead of injecting the sample itself. Volatile compounds partition into the gas phase at equilibrium, and an aliquot is transferred to the GC. This keeps non-volatile matrix out of the inlet and column.
FID quantifies well but cannot identify peaks. MS confirms solvent identity by spectrum, resolves co-eluting solvents through extracted ions, and detects unexpected volatile impurities. Many pharmaceutical laboratories still use FID for routine USP <467> testing and use MS for investigation.
Analyte partitioning depends on matrix composition, salt content, pH and temperature. Adding salt or a dilution solvent such as DMSO can shift equilibrium. Calibration with matrix-matched standards or standard addition is recommended to maintain accuracy across differing samples.
GC-MS analyzes compounds that can be vaporized without decomposition, generally with molecular weights below about 500 Da. Examples are solvents, pesticides, hydrocarbons, fatty acid methyl esters, flavors and many drugs. Polar or non-volatile analytes can be made suitable by derivatization, for example silylation.
Full scan records the whole mass range, for example m/z 35 to 550, and gives spectra for library identification of unknowns. Selected ion monitoring records only chosen ions, which increases dwell time per ion and typically improves sensitivity by ten to one hundred times, but it loses information about unexpected compounds.
Yes, with conditions. Hydrogen gives faster separations and lower cost, but it can react with some analytes, change spectra in electron ionization sources, and requires safety measures. Many systems need a hydrogen-compatible ion source and method revalidation before replacing helium in regulated work.




