Headspace GC-MS System

顶空气质联用仪

  • SKU GCM-0004
  • GC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Vial capacity10, 20 or 22 mL; 12–120 positions
Oven temperature rangeambient +10 to 300 °C
Transfer line temperatureup to 250 °C
Injection precision (RSD)≤ 3%
Carryover≤ 0.05%
Mass range (MS)m/z 1.6–1050
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA Method 8270, EPA Method 524.2, EPA Method 8260

What is the Headspace GC-MS System?

A headspace GC-MS combines an automated headspace sampler with a GC-MS so that volatile compounds are analyzed from the vapor phase above a sample. It avoids injecting non-volatile matrix and is used for residual solvents, blood alcohol, off-odors and volatile impurities in solids and liquids.

What is the Headspace GC-MS System?

A headspace GC-MS combines an automated headspace sampler with a GC-MS so that volatile compounds are analyzed from the vapor phase above a sample. It avoids injecting non-volatile matrix and is used for residual solvents, blood alcohol, off-odors and volatile impurities in solids and liquids.

Overview

A headspace GC-MS sample is sealed in a 10, 20 or 22 mL vial, heated at a set temperature, typically 40 to 200 °C, and allowed to reach equilibrium between liquid or solid and gas phases. An aliquot of vapor is then transferred through a heated transfer line by pressurized loop or syringe injection into the GC inlet. Since the matrix stays in the vial, inlet liners and columns stay cleaner and maintenance intervals lengthen. Mass spectrometric detection adds identification power over flame ionization detection, making it possible to confirm residual solvents and unknown off-odors. Dynamic headspace or trap-based variants increase sensitivity for ultra-trace volatiles. Precision depends on temperature control and vial sealing, with relative standard deviation below 2 to 5 percent expected in routine use. Headspace sampling cannot analyze semi-volatile or non-volatile compounds.

How does it work?

In GC-MS, a liquid or gas sample is vaporized in a heated inlet and carried by helium or hydrogen through a capillary column, typically 15 to 60 m long with a 0.25 mm internal diameter. Compounds separate according to boiling point and interaction with the stationary phase and elute at characteristic retention times. The column exit feeds an ion source, most often electron ionization at 70 eV, which produces reproducible fragmentation patterns that can be matched against libraries such as NIST. Ions are filtered by a mass analyzer, commonly a quadrupole, and counted by an electron multiplier. Acquisition can run in full scan for identification or selected ion monitoring for higher sensitivity. A turbomolecular pump maintains the high vacuum required in the analyzer.

What are the key features?

  • Automated heated-oven headspace sampler with 12 to 120 vial capacity and agitation
  • Pressure-balanced or loop injection giving relative standard deviation below 3 percent
  • Inert heated transfer line minimizing carryover and analyte adsorption
  • Optional trap concentration for dynamic headspace at sub-ppb levels
  • Mass-selective detection confirming residual solvents and unknown volatile peaks
  • Software templates for USP residual solvent and blood alcohol methods

What are the technical specifications?

A typical headspace gc-ms system configuration offers vial capacity of 10, 20 or 22 mL; 12–120 positions, oven temperature range of ambient +10 to 300 °C, transfer line temperature of up to 250 °C, injection precision (RSD) of ≤ 3%, carryover of ≤ 0.05% and mass range (MS) of m/z 1.6–1050. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Headspace GC-MS System is used in residual solvents in pharmaceuticals, blood alcohol and volatile toxicology, off-odor analysis in packaging and plastics, volatile organics in soil and water and volatile impurities in cosmetics and consumer goods. Across the wider GC-MS class, laboratories also deploy it for environmental VOC and semi-volatile analysis, pesticide residue testing in food and forensic toxicology and drug screening.

Which standards and certifications apply?

Relevant standards and methods include EPA Method 8270, EPA Method 524.2, EPA Method 8260, ASTM D5769, USP <467> Residual Solvents, ISO 11423, EN 15662, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the GC-MS on a level bench with a dedicated power outlet, a vented exhaust for the rotary pump, and stable room temperature. Use high-purity carrier gas of at least 99.999 percent with moisture and oxygen traps, since contamination shortens column and filament life. Perform an autotune with perfluorotributylamine before each batch and verify mass accuracy and isotope ratios. Routine maintenance includes replacing inlet liners, septa and gold seals, trimming the column, cleaning the ion source and changing pump oil. Keep leak checks in the daily routine, as air peaks at m/z 28 and 32 indicate a leak. Regulated laboratories should require audit trails, electronic signatures and access control that support 21 CFR Part 11.

How do I select the right Headspace GC-MS System?

Select headspace GC-MS for volatile analytes in dirty, solid or viscous matrices where direct injection would foul the system. Choose pyrolysis or thermal desorption for semi-volatile or polymer samples. In an RFQ, specify vial size, oven range, injection mode, carryover, and whether USP residual solvent or blood alcohol methods must be supported.

How does it compare with other GC-MS variants?

Select a GC-MS by matching the detector to the task. A single quadrupole is the economical choice for routine identification and quantitation of residues, volatiles and unknowns using library matching. A triple quadrupole configuration is needed when matrix interference limits sensitivity, as in pesticide multi-residue or dioxin-related work. Time-of-flight offers fast acquisition and accurate mass for non-targeted screening. Headspace and pyrolysis configurations suit specific sample types without solvent extraction. Check the scan speed, mass range, source cleanliness tolerance, and whether the ion source can be changed without venting. Verify support for helium alternatives such as hydrogen, autosampler capacity, and library and data-integrity software. Ask vendors for detection-limit data, such as octafluoronaphthalene instrument detection limit, measured on the exact configuration quoted.

Full specifications

Full specifications
Vial capacity10, 20 or 22 mL; 12–120 positions
Oven temperature rangeambient +10 to 300 °C
Transfer line temperatureup to 250 °C
Injection precision (RSD)≤ 3%
Carryover≤ 0.05%
Mass range (MS)m/z 1.6–1050
Scan speed (MS)up to 10000 Da/s
Detection limit (ethanol in water)≤ 0.5 mg/L (typical)
Equilibration time1–60 min programmable
Carrier gasHelium or hydrogen, 99.999%

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Residual solvents in pharmaceuticals
  • Blood alcohol and volatile toxicology
  • Off-odor analysis in packaging and plastics
  • Volatile organics in soil and water
  • Volatile impurities in cosmetics and consumer goods

Key features

  • Automated heated-oven headspace sampler with 12 to 120 vial capacity and agitation
  • Pressure-balanced or loop injection giving relative standard deviation below 3 percent
  • Inert heated transfer line minimizing carryover and analyte adsorption
  • Optional trap concentration for dynamic headspace at sub-ppb levels
  • Mass-selective detection confirming residual solvents and unknown volatile peaks
  • Software templates for USP residual solvent and blood alcohol methods

Frequently asked questions about Headspace GC-MS System

Headspace sampling analyzes the vapor above a heated, sealed sample instead of injecting the sample itself. Volatile compounds partition into the gas phase at equilibrium, and an aliquot is transferred to the GC. This keeps non-volatile matrix out of the inlet and column.