Single-Drum Friability Tester — product photo

Single-Drum Friability Tester

单转鼓脆碎度测试仪

  • SKU FRT-0001
  • Friability Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Number of drums1
Drum inner diameterapprox. 287 mm
Drum depthapprox. 38 mm
Rotation speed25 ± 1 rpm
Revolution preset range1–9999 rev
Timer range1–99 min
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1216>, Ph. Eur. 2.9.7, JP 6.10

What is the Single-Drum Friability Tester?

A single-drum friability tester rotates one standard drum at 25 rpm and counts revolutions to a preset value. It is the basic, economical choice for laboratories that run a modest number of friability tests per day and weigh samples manually.

What is the Single-Drum Friability Tester?

A single-drum friability tester rotates one standard drum at 25 rpm and counts revolutions to a preset value. It is the basic, economical choice for laboratories that run a modest number of friability tests per day and weigh samples manually.

Overview

The single-drum configuration consists of one transparent acrylic drum mounted on a horizontal shaft, a synchronous or stepper drive motor, and a digital controller with revolution presetting. The drum follows the pharmacopoeial geometry, with an internal diameter of about 287 mm and a curved baffle that lifts and drops the tablets. The operator loads the weighed sample, sets 100 revolutions, starts the run and removes the tablets for dedusting and reweighing. Speed is typically fixed at 25 rpm with a tolerance of about 1 rpm. The design is compact, easy to clean and simple to verify, and it needs little training. The limitation is capacity, because only one sample can be tested at a time, and there is no automatic counting or weighing.

How does it work?

A friability tester holds a transparent drum, usually 287 mm in diameter, on a horizontal axis and rotates it at 25 rpm. A curved radial baffle inside the drum lifts the tablets and drops them from a height of about 156 mm on every turn, so each tablet falls repeatedly onto the drum wall and onto other tablets. A pre-weighed sample, normally 6.5 g or 10 tablets, is run for 100 revolutions (4 minutes). Loose dust is removed and the tablets are weighed again. Friability is the percentage loss of mass, and the pharmacopoeias accept a value not above 1.0 percent for most products. The main components are the drum, drive motor, revolution counter and timer, and a speed control. Advanced models add automatic tablet counting, dust removal and an integrated balance.

What are the key features?

  • One transparent acrylic drum meeting pharmacopoeial geometry with curved radial baffle
  • Digital revolution preset with automatic stop at the target count
  • Fixed 25 rpm speed with low-vibration synchronous drive
  • Quick-release drum cover for fast loading and cleaning
  • Compact benchtop footprint suitable for shared laboratory space

What are the technical specifications?

A typical single-drum friability tester configuration offers number of drums of 1, drum inner diameter of approx. 287 mm, drum depth of approx. 38 mm, rotation speed of 25 ± 1 rpm, revolution preset range of 1–9999 rev and timer range of 1–99 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Single-Drum Friability Tester is used in routine batch release testing, low-volume QC laboratories and academic formulation teaching. Across the wider Friability Testers class, laboratories also deploy it for pharmaceutical QC release testing, tablet formulation development and in-process control during compression.

Which standards and certifications apply?

Relevant standards and methods include USP <1216>, Ph. Eur. 2.9.7, JP 6.10 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the tester on a level, vibration-free bench, because vibration and tilt change the tablet fall pattern. Verify drum speed and revolution count at installation and at defined intervals using a calibrated tachometer or stopwatch. Inspect the drum and baffle for scratches, cracks and residue, and clean with a non-abrasive cloth to avoid altering the surface. Keep tablets dedusted with a soft brush and weigh on a balance of at least 0.1 mg readability. Ambient humidity influences hygroscopic tablets, so record the conditions. For regulated laboratories, document the installation, operational and performance qualification and, where software is used, evidence of audit trails and access control.

How do I select the right Single-Drum Friability Tester?

Select the single-drum model when daily sample numbers are low and manual weighing is acceptable. Choose a dual-drum or automatic model if you test more than a few samples per shift. In an RFQ, specify drum dimensions to the pharmacopoeia, speed tolerance, revolution preset range, power supply and whether a calibration certificate for speed is required.

How does it compare with other Friability Testers variants?

The decisive choice is throughput versus automation. A single-drum unit suits low-volume QC laboratories, while a dual-drum unit tests two samples in parallel, which also supports duplicate testing for development work. Check that drum dimensions and speed match the pharmacopoeial specification of the target market, and that the speed is verified by a revolution counter and not just a dial setting. If the laboratory handles many batches a day, automatic counting, dust removal and balance integration reduce handling errors and operator time. For regulated sites, confirm that electronic records, audit trails and user access levels are available. Also consider drum material, because antistatic or polished acrylic drums reduce dust adhesion on some granulations. Finally, confirm the tester can accept large or oddly shaped tablets if the portfolio contains them.

Full specifications

Full specifications
Number of drums1
Drum inner diameterapprox. 287 mm
Drum depthapprox. 38 mm
Rotation speed25 ± 1 rpm
Revolution preset range1–9999 rev
Timer range1–99 min
Drum materialTransparent acrylic
DriveSynchronous motor
Power supply220 V, 50/60 Hz
Dimensions (W×D×H)approx. 330 × 280 × 420 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine batch release testing
  • Low-volume QC laboratories
  • Academic formulation teaching

Key features

  • One transparent acrylic drum meeting pharmacopoeial geometry with curved radial baffle
  • Digital revolution preset with automatic stop at the target count
  • Fixed 25 rpm speed with low-vibration synchronous drive
  • Quick-release drum cover for fast loading and cleaning
  • Compact benchtop footprint suitable for shared laboratory space

Frequently asked questions about Single-Drum Friability Tester

Yes, if the drum dimensions, baffle geometry and 25 rpm speed comply with the pharmacopoeia. Compliance depends on verified mechanical parameters, not on the number of drums, so a single-drum unit is fully adequate for routine friability testing.

Request a quotation for the Single-Drum Friability Tester

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.