Enclosed Decontamination Shower Booth
封闭式去污淋浴间
- SKU ESH-0005
- Emergency Showers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Type | Enclosed decontamination booth |
|---|---|
| Shower flow | 75–115 L/min |
| Water temperature | 16–38 °C tepid |
| Head height | 2000–2400 mm |
| Booth width | 1000–1500 mm |
| Containment | Kerb or tray with drain |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ANSI/ISEA Z358.1 (emergency eyewash and shower equipment), EN 15154-1 (body showers for laboratories), EN 15154-2 (eyewash)
What is the Enclosed Decontamination Shower Booth?
An enclosed decontamination shower booth adds curtains, walls and containment so contaminated water and clothing stay inside. It suits strong corrosives, heat-sensitive or large spill hazards and greatly reduces slippery floor risk.
What is the Enclosed Decontamination Shower Booth?
An enclosed decontamination shower booth adds curtains, walls and containment so contaminated water and clothing stay inside. It suits strong corrosives, heat-sensitive or large spill hazards and greatly reduces slippery floor risk.
Overview
The booth surrounds a drench shower with a privacy curtain, side panels and a raised kerb or tray so that contaminated water is contained and drained rather than spreading across the floor. It may include an eyewash and a step or ramp for entry, and the enclosure keeps the user from being seen and from spreading contamination by walking away wet. The shower delivers 75–115 L/min of tepid water from a head at 2000–2400 mm, and the enclosure is sized to allow movement with hands free. Materials are corrosion-resistant, and the drain connects to a chemical waste or neutralisation system where needed. Weekly activation and annual inspection follow the same standards as open showers, and the enclosure itself must be cleaned and inspected.
How does it work?
An emergency shower is a fixed deluge device that floods the user with water at a controlled rate, temperature and pattern so that chemicals are diluted and washed from skin, hair and clothing. Water comes from a dedicated supply through a stay-open valve, so once the user pulls the handle both hands are free. The shower head distributes the flow over the body, and the column height and spray diameter are specified so a standing person is fully covered. Flow is typically 75–115 L/min at a pressure of 1.5–3.0 bar, and water should be tepid, roughly 16–38 °C, because cold water can prevent a casualty from staying under the shower long enough. A floor drain and a clear area around the unit are part of the installation, and combination units add eyewash heads at working height.
What are the key features?
- Privacy curtain and side panels
- Raised kerb or containment tray
- Tepid drench shower at 75–115 L/min
- Optional eyewash inside the booth
- Corrosion-resistant materials
- Drain to chemical waste where needed
What are the technical specifications?
A typical enclosed decontamination shower booth configuration offers type of Enclosed decontamination booth, shower flow of 75–115 L/min, water temperature of 16–38 °C tepid, head height of 2000–2400 mm, booth width of 1000–1500 mm and containment of Kerb or tray with drain. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Enclosed Decontamination Shower Booth is used in strong corrosive handling, heat-sensitive chemical areas, large spill-risk processes and battery and plating plants. Across the wider Emergency Showers class, laboratories also deploy it for chemical laboratories, battery and plating areas and pharmaceutical and QC laboratories.
Which standards and certifications apply?
Relevant standards and methods include ANSI/ISEA Z358.1 (emergency eyewash and shower equipment), EN 15154-1 (body showers for laboratories), EN 15154-2 (eyewash), DIN 12899 (emergency safety showers), ISO 3864 (safety signage) and GB/T 38144 (emergency shower and eyewash). Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Activate every shower weekly to flush stagnant water and verify that the valve opens fully and stays open, and inspect annually for flow, temperature, spray pattern and height against ANSI/ISEA Z358.1 or EN 15154. Keep the approach clear of stored equipment, since an obstructed shower cannot be used in an emergency. Maintain tepid water within the required range, and check the mixing valve or heater regularly. Provide a floor drain or containment so contaminated water does not spread, and confirm the unit is not used for any other purpose. Record weekly and annual checks, and train staff on locations and on flushing for at least 15 minutes before seeking medical help.
How do I select the right Enclosed Decontamination Shower Booth?
Choose a booth where contamination must be contained or privacy is needed, and where contaminated water cannot drain freely. Confirm enclosure size and drain route. RFQ: hazards, containment needs, drain destination, eyewash, access and signage requirements.
How does it compare with other Emergency Showers variants?
Choose the type by the hazard and the room. A floor-mounted drench shower suits general laboratories, while a wall-mounted unit saves floor space where the wall is rated for the load. A combination shower and eyewash covers whole-body and eye exposure in one unit, which is often the most efficient layout. Add a tempered water supply where the incoming water is too cold, since cold water discourages full 15-minute flushing. For strong corrosives, heat-sensitive chemicals or large spill risks, an enclosed booth with a curtain or drainage keeps contaminated water contained. Confirm access within 10 seconds' travel of hazards, on the same level, unobstructed, and verify flow, temperature and spray coverage at commissioning. Provide signage and a floor drain.
Full specifications
| Type | Enclosed decontamination booth |
|---|---|
| Shower flow | 75–115 L/min |
| Water temperature | 16–38 °C tepid |
| Head height | 2000–2400 mm |
| Booth width | 1000–1500 mm |
| Containment | Kerb or tray with drain |
| Eyewash | Optional, 1.5–2 L/min per eye |
| Materials | Corrosion-resistant panels |
| Drainage | To chemical waste if required |
| Access | Step or ramp |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Strong corrosive handling
- Heat-sensitive chemical areas
- Large spill-risk processes
- Battery and plating plants
Key features
- Privacy curtain and side panels
- Raised kerb or containment tray
- Tepid drench shower at 75–115 L/min
- Optional eyewash inside the booth
- Corrosion-resistant materials
- Drain to chemical waste where needed
Frequently asked questions about Enclosed Decontamination Shower Booth
To contain contaminated water and clothing, protect privacy and stop the casualty spreading contamination by walking away wet. It also keeps the surrounding floor safe from a large water spill.
Often yes. Water carrying strong corrosives or hazardous chemicals should be collected and neutralised or treated before disposal, according to local rules and the chemicals involved.
Activate the shower weekly, inspect flow and temperature annually, and clean the panels, curtain and tray on a set schedule. Check the drain and kerb for leaks or blockages.
Within 10 seconds' travel of the hazard, about 15–20 m, on the same level and along an unobstructed path. The hazard and shower should not be separated by a door the casualty must open.
Because very cold water can cause shock and discourage a casualty from remaining for the full 15 minutes. ANSI/ISEA Z358.1 specifies tepid water, roughly 16–38 °C, for effective decontamination.
Activate weekly to flush the line and confirm the valve opens and stays open, and inspect annually for flow, temperature, spray pattern and height. Record both checks for audit and insurance.
Related models