Automated Capillary Photometry ESR Analyzer
全自动毛细管光度血沉分析仪
- SKU ESA-0001
- ESR Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 20–60 samples per batch, about 30 min |
|---|---|
| Measuring range | 0–140 mm/h |
| Sample volume | 180–200 µL per capillary |
| Tube type | Disposable glass or plastic capillaries |
| Temperature control | 18–25 °C ±0.5 °C |
| Anticoagulant | EDTA-K2 whole blood or sodium citrate |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, ICSH ESR reference method, CLSI H02
What is the Automated Capillary Photometry ESR Analyzer?
An automated capillary photometry ESR analyzer loads a carousel of capillary tubes, holds them vertically at controlled temperature and reads the falling plasma interface with photodiode arrays. It reports a Westergren-comparable result in about thirty minutes and suits laboratories with routine blood count workloads.
What is the Automated Capillary Photometry ESR Analyzer?
An automated capillary photometry ESR analyzer loads a carousel of capillary tubes, holds them vertically at controlled temperature and reads the falling plasma interface with photodiode arrays. It reports a Westergren-comparable result in about thirty minutes and suits laboratories with routine blood count workloads.
Overview
The instrument accepts a batch of capillary tubes, usually 20 to 60 positions, and mixes each tube gently before the measurement begins. Temperature in the measuring compartment is held within a narrow band, typically 18 to 25 degrees Celsius, because sedimentation is temperature dependent. Photodiode arrays scan the tubes at intervals and record the position of the plasma and cell column interface; software fits the resulting curve and extrapolates the one-hour value. Results are printed or transmitted to the LIS with a flag when a measurement fails because of a bubble, clot, or insufficient blood. The workflow requires little technician time, which is the main reason laboratories adopt it, and consumables are limited to capillaries, cleaning solution and control material.
How does it work?
When anticoagulated blood stands in a vertical tube, red cells aggregate and settle, leaving a column of clear plasma above them. The height of that plasma column after one hour, expressed in millimeters, is the Westergren sedimentation rate. Aggregation is promoted by fibrinogen and globulins, so an elevated rate indicates an acute phase response even though the test is not specific for any diagnosis. Automated instruments reproduce this process with capillary tubes held vertically at a controlled temperature, usually 18 to 25 degrees Celsius, and track the falling interface with an array of photodiodes or an infrared sensor. Because the settling curve is nonlinear, algorithms extrapolate a one-hour value from a shorter measurement period, and the algorithms are validated against the Westergren reference method. Some instruments read standard Westergren tubes with a barcode instead of using capillary tubes.
What are the key features?
- Carousel loading of 20 to 60 capillary tubes per batch
- Photodiode array reading of the plasma-cell interface
- Temperature-controlled measuring compartment between 18 and 25 °C
- Automatic gentle mixing before each measurement
- Extrapolation algorithm validated against the Westergren method
- Flags for bubbles, clots and insufficient sample volume
What are the technical specifications?
A typical automated capillary photometry esr analyzer configuration offers throughput of 20–60 samples per batch, about 30 min, measuring range of 0–140 mm/h, sample volume of 180–200 µL per capillary, tube type of Disposable glass or plastic capillaries, temperature control of 18–25 °C ±0.5 °C and anticoagulant of EDTA-K2 whole blood or sodium citrate. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Capillary Photometry ESR Analyzer is used in routine ESR testing alongside blood counts, outpatient inflammation screening, rheumatology clinic monitoring and pre-operative assessment. Across the wider ESR Analyzers class, laboratories also deploy it for screening for inflammatory and infectious disease, follow-up of rheumatoid arthritis and vasculitis and monitoring of polymyalgia rheumatica and giant cell arteritis.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, ICSH ESR reference method, CLSI H02, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the analyzer on a stable surface free of vibration, because any movement disturbs the settling interface, and keep it away from direct sunlight and heat sources so that the measuring position stays within the specified temperature range. Verify performance at installation against the Westergren reference method on at least forty samples spanning normal and elevated values, and repeat the comparison after major service. Run control material at the recommended frequency, usually daily when samples are reported, and keep the optical windows, tubes and holders clean. Use only the specified capillary or Westergren tubes, since tube bore and cleanliness affect the result, and treat all blood samples and used tubes as infectious waste.
How do I select the right Automated Capillary Photometry ESR Analyzer?
Choose this variant when ESR requests are routine and batch handling suits the workflow, typically more than twenty per day. In the RFQ specify the batch size, the capillary type and volume, whether EDTA tubes collected for the blood count can be reused, and the required temperature tolerance. Ask for the correlation study against the Westergren method, including performance in the normal range.
How does it compare with other ESR Analyzers variants?
Choose an ESR analyzer when the test is requested often enough that manual Westergren tubes consume unacceptable technician time, generally more than ten to twenty tests per day. Compare instruments by throughput, sample volume, tube type and the temperature control of the measuring position. Capillary photometry models accept small volumes and suit pediatric work, while instruments reading standard Westergren tubes may be preferred where the reference method must be preserved for accreditation. Check whether the analyzer needs a dedicated blood collection tube or can use an EDTA or citrate tube already collected, and whether mixing is automatic. Confirm quality control material availability, calibration or verification procedure, and biosafety features such as closed tube handling.
Full specifications
| Throughput | 20–60 samples per batch, about 30 min |
|---|---|
| Measuring range | 0–140 mm/h |
| Sample volume | 180–200 µL per capillary |
| Tube type | Disposable glass or plastic capillaries |
| Temperature control | 18–25 °C ±0.5 °C |
| Anticoagulant | EDTA-K2 whole blood or sodium citrate |
| Display and printer | LCD display with built-in thermal printer |
| Interfaces | RS-232, USB, LAN with LIS option |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine ESR testing alongside blood counts
- Outpatient inflammation screening
- Rheumatology clinic monitoring
- Pre-operative assessment
Key features
- Carousel loading of 20 to 60 capillary tubes per batch
- Photodiode array reading of the plasma-cell interface
- Temperature-controlled measuring compartment between 18 and 25 °C
- Automatic gentle mixing before each measurement
- Extrapolation algorithm validated against the Westergren method
- Flags for bubbles, clots and insufficient sample volume
Frequently asked questions about Automated Capillary Photometry ESR Analyzer
Yes, many capillary photometry analyzers accept blood already collected in EDTA, which avoids a second venepuncture and suits clinics that run both tests together. Confirm the required volume and how the blood is transferred into the capillary, and note that citrated blood gives a different reference interval.
Common causes are an air bubble trapped in the capillary, a clot from inadequate mixing or delay, insufficient blood volume, or a very high sedimentation rate that makes interface detection ambiguous. The analyzer flags the affected position so that the sample can be repeated with a new capillary.
Clean the capillary holders and optical windows each working day, and immediately if blood or dust is visible. Run the cleaning program with the specified solution monthly, or more often in dusty environments. Contamination of the optical path causes interface detection errors, which appear as failed measurements or biased results.
An elevated sedimentation rate indicates an acute phase response and is associated with infection, inflammation, autoimmune disease, some malignancies and tissue damage. It is a nonspecific test, so results are interpreted with the clinical picture, with other acute phase markers such as C-reactive protein, and with serial measurements in the same patient.
Automated analyzers are calibrated to give results comparable with the Westergren reference method, and suppliers usually report correlation coefficients above 0.9 with acceptable bias. Laboratories must still verify the comparison locally, especially in the normal range where reporting differences influence clinical decisions, and document the results.
Many automated instruments use EDTA whole blood collected for the blood count, while others require a dedicated capillary or citrate tube. Westergren reference tubes are read directly by some analyzers. Tube bore, fill volume and anticoagulant all influence the result, so use only the tubes specified by the manufacturer.