Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer
红外感应炉碳硫元素分析仪
- SKU ELA-0003
- Elemental Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Elements measured | C, S |
|---|---|
| Carbon range | 0.0001–6% |
| Sulfur range | 0.0001–0.35% |
| Sample mass | 0.2–1 g |
| Furnace | High-frequency induction, 15–25 MHz |
| Analysis time | 30–60 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1019, ASTM D5373, ASTM D5453
What is the Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer?
An infrared induction furnace carbon-sulfur analyzer combusts metals, ores, and inorganic solids in oxygen and measures CO2 and SO2 by infrared absorption. It gives results in 30–60 seconds for carbon and sulfur in steels and alloys.
What is the Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer?
An infrared induction furnace carbon-sulfur analyzer combusts metals, ores, and inorganic solids in oxygen and measures CO2 and SO2 by infrared absorption. It gives results in 30–60 seconds for carbon and sulfur in steels and alloys.
Overview
This platform places 0.2–1 g of sample and accelerators in a ceramic crucible, which is heated by a 15–25 MHz induction coil in an oxygen stream to 1500–2000 °C. The gases are dedusted, dried, and measured by infrared cells tuned to CO2 near 4.26 µm and SO2 near 7.35 µm. Separate low and high range cells give a dynamic range from 1 ppm to 6% carbon and 1 ppm to 0.35% sulfur. Results are calibrated with certified steel and iron standards, and are typically reported with a repeatability of 0.5–1% RSD. Induction heating does not work well with non-conductive materials, so a resistance furnace variant is used for ores and cement. The instrument is a workhorse in steel mills and foundries, where carbon and sulfur influence strength, hardness, and machinability.
How does it work?
Elemental analyzers decompose a sample completely, so the element of interest can be measured regardless of its chemical form. Combustion systems burn organic samples in oxygen at about 1000 °C and detect CO2, H2O, N2, and SO2 by thermal conductivity or infrared cells. Inert gas fusion melts metals and ceramics in graphite crucibles, releasing oxygen as CO, and nitrogen and hydrogen as N2 and H2. Induction furnace analyzers combust metals in oxygen and detect CO2 and SO2 by infrared. For liquid fuels, UV fluorescence detects SO2 excited at about 215 nm and chemiluminescence detects nitric oxide reacting with ozone. Combustion ion chromatography absorbs halogen gases into solution and separates the anions on an ion-exchange column. All methods are calibrated against certified standards and require blank control.
What are the key features?
- High-frequency induction heating reaches 1500–2000 °C within seconds.
- Low and high range infrared cells span ppm to percent concentrations.
- Analysis in 30–60 seconds supports production control.
- Automatic cleaning and crucible handling options reduce operator workload.
- Calibration with certified steel and iron reference materials.
What are the technical specifications?
A typical infrared induction furnace carbon-sulfur elemental analyzer configuration offers elements measured of C, S, carbon range of 0.0001–6%, sulfur range of 0.0001–0.35%, sample mass of 0.2–1 g, furnace of High-frequency induction, 15–25 MHz and analysis time of 30–60 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer is used in steel and iron production control, alloy and ferroalloy testing, metal powders for additive manufacturing and incoming material verification. Across the wider Elemental Analyzers class, laboratories also deploy it for materials composition verification, petroleum and fuel quality testing and polymer and electronics halogen screening.
Which standards and certifications apply?
Relevant standards and methods include ASTM E1019, ASTM D5373, ASTM D5453, ASTM D4629, ISO 10304-1, ASTM D7359, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Elemental analyzers require stable power, clean dry gases of 99.99–99.999% purity, and exhaust extraction for SO2 and combustion gases. Microbalance-based systems need a vibration-free bench and temperature stability within about 2 °C. Calibrate with certified reference materials at installation, after maintenance, and at defined intervals, and run check standards at the start of each batch. Consumables such as combustion tubes, crucibles, and traps have defined lifetimes based on sample count. Samples must be homogeneous, dry, and free of surface contamination. Laboratories under ISO/IEC 17025 or GLP should keep calibration records, balance certificates, and maintenance logs, and validate methods on matrix-matched standards. Electrical safety of laboratory equipment is commonly assessed to IEC 61010-1.
How do I select the right Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer?
Select this platform for carbon and sulfur in steels, cast iron, and metals where speed and ppm sensitivity matter. For organic samples use a CHNS analyzer, and for minerals use a resistance furnace. Specify ranges, number of IR cells, autosampler and standards such as ASTM E1019.
How does it compare with other Elemental Analyzers variants?
Choose by the element and matrix rather than by instrument name. Organic powders needing C, H, N, S call for a flash combustion analyzer, and metals needing oxygen, nitrogen, or hydrogen need inert gas fusion. Carbon and sulfur in steel and minerals call for an infrared induction furnace analyzer. Sulfur and nitrogen at mg/kg levels in liquid fuels call for UV fluorescence and chemiluminescence analyzers. Total halogens and sulfur in polymers, electronics, or waste point to combustion ion chromatography. Next specify concentration range, sample mass, required standards, autosampler capacity, and throughput. Ask suppliers for repeatability on reference materials representing your matrix, and confirm consumable requirements such as crucibles, catalysts, reagents, and high-purity gases, since these often dominate operating costs.
Full specifications
| Elements measured | C, S |
|---|---|
| Carbon range | 0.0001–6% |
| Sulfur range | 0.0001–0.35% |
| Sample mass | 0.2–1 g |
| Furnace | High-frequency induction, 15–25 MHz |
| Analysis time | 30–60 s |
| Carbon precision (RSD) | ≤0.5% at 0.1% C |
| Sulfur precision (RSD) | ≤1.0% at 0.01% S |
| Oxygen supply | ≥99.5%, 2–3 bar |
| Detector | Infrared absorption cells |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Steel and iron production control
- Alloy and ferroalloy testing
- Metal powders for additive manufacturing
- Incoming material verification
Key features
- High-frequency induction heating reaches 1500–2000 °C within seconds.
- Low and high range infrared cells span ppm to percent concentrations.
- Analysis in 30–60 seconds supports production control.
- Automatic cleaning and crucible handling options reduce operator workload.
- Calibration with certified steel and iron reference materials.
Frequently asked questions about Infrared Induction Furnace Carbon-Sulfur Elemental Analyzer
Accelerators such as tungsten and iron couple efficiently with the induction field, raise combustion temperature, and ensure quick complete oxidation. Their carbon and sulfur blanks must be low and consistent, because blanks define the lowest measurable concentration.
Typical instruments cover carbon from about 1 ppm to 6% and sulfur from about 1 ppm to 0.35% using low and high range infrared cells. Extended ranges are available for ferroalloys and cast iron by reducing sample mass.
Yes. Powders, drillings, chips, and pins can be analyzed when weighed to 0.1 mg and mixed with accelerators. Very fine powders may require tin capsules or covers to avoid loss in the gas stream.
An elemental analyzer measures the total mass fraction of specific elements in a sample. It decomposes the sample by combustion or fusion, converts elements to detectable gases or ions, and quantifies them using thermal conductivity, infrared, fluorescence, chemiluminescence, or ion chromatography.
Common targets are carbon, hydrogen, nitrogen, sulfur, oxygen, and halogens such as chlorine, bromine, and fluorine. Trace metals are normally measured by atomic spectroscopy or ICP instead, so elemental analyzers cover mainly light, non-metallic elements and gases in metals.
Often yes. Flash combustion, inert gas fusion, induction furnace, UV fluorescence, and combustion ion chromatography each target different elements and matrices. Some platforms are modular, but no single design is optimal for all elements and sample types.