Skip to main content
Lab Manufacturers China
Benchtop Cytotoxic Safety Cabinet — product photo

Benchtop Cytotoxic Safety Cabinet

台式细胞毒性药物安全柜

  • SKU CYC-0004
  • Cytotoxic Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Cabinet typeBenchtop cytotoxic Class II
Inflow velocity0.38–0.51 m/s
Downflow velocity0.25–0.35 m/s
Width900–1500 mm
Work height500–650 mm
HEPA gradeH14 supply and exhaust
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12469 (biosafety cabinets), NSF/ANSI 49 (biosafety cabinetry), USP <800> (hazardous drugs handling in healthcare settings)

What is the Benchtop Cytotoxic Safety Cabinet?

A benchtop cytotoxic safety cabinet is a compact unit for small-volume hazardous drug preparation. It fits a satellite or clinic pharmacy where space is limited and throughput is low at a single workstation.

What is the Benchtop Cytotoxic Safety Cabinet?

A benchtop cytotoxic safety cabinet is a compact unit for small-volume hazardous drug preparation. It fits a satellite or clinic pharmacy where space is limited and throughput is low at a single workstation.

Overview

The benchtop unit is 900–1500 mm wide and sits on a workbench, with a stainless work surface and a sash that marks the working height. Inflow is 0.38–0.51 m/s and downflow 0.25–0.35 m/s, and exhaust is HEPA filtered to a dedicated duct or through a canopy where permitted. Because the internal volume and working height are smaller, the range of preparations is limited to small volumes and standard vial sizes, and large bags or devices may not fit. Airflow alarms and a pressure gauge are standard. The unit is certified for HEPA integrity, airflow and containment like a full-size cabinet, and the same decontamination and waste procedures apply. It is used in satellite pharmacies, clinics and small compounding units.

How does it work?

Cytotoxic cabinets combine the airflow of a Class II biosafety cabinet with a design that keeps hazardous drug particles and vapours away from the operator and out of the room. Room air enters at the front grille, forming an air curtain across the opening, and HEPA-filtered air flows downward over the work zone to protect the preparation. Exhaust is HEPA filtered, and the cabinet is typically operated without recirculation into the work zone, with all exhaust sent to a dedicated duct. Many designs hold the work surface at negative pressure and use a split or closed front so drug aerosols cannot escape. Some pharmacy units use sealed glove ports, giving isolator-style containment with no direct operator contact. Surfaces are smooth stainless steel or plastic for frequent decontamination, and the cabinet is a classified environment for aseptic operations. Certification covers HEPA integrity, airflow and containment testing.

What are the key features?

  • Compact bench-mounted cabinet 900–1500 mm wide
  • Inflow 0.38–0.51 m/s and downflow 0.25–0.35 m/s
  • HEPA-filtered exhaust to duct or canopy
  • Airflow alarm and pressure gauge
  • Stainless work surface
  • Small-volume single-operator workflow

What are the technical specifications?

A typical benchtop cytotoxic safety cabinet configuration offers cabinet type of Benchtop cytotoxic Class II, inflow velocity of 0.38–0.51 m/s, downflow velocity of 0.25–0.35 m/s, width of 900–1500 mm, work height of 500–650 mm and HEPA grade of H14 supply and exhaust. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Cytotoxic Safety Cabinet is used in satellite pharmacy compounding, clinic and outpatient doses, small-volume hazardous prep and teaching and demonstration. Across the wider Cytotoxic Cabinets class, laboratories also deploy it for antineoplastic drug compounding, hospital pharmacy aseptic preparation and hazardous drug dose preparation.

Which standards and certifications apply?

Relevant standards and methods include EN 12469 (biosafety cabinets), NSF/ANSI 49 (biosafety cabinetry), USP <800> (hazardous drugs handling in healthcare settings), USP <797> (pharmaceutical compounding, sterile preparations), ISO 14644-1 (cleanroom classification) and EU GMP Annex 1 (sterile manufacturing). Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the cabinet in a controlled area with correct room pressure relationships, commonly a negative-pressure buffer room, and away from doors and air diffusers. Change gloves and sleeves on a defined schedule and inspect them for pinholes, since operator protection depends on intact barrier and airflow. Decontaminate the work surface and interior after every session and use a closed-system transfer device where required. Verify HEPA integrity, inflow and containment at installation and at least annually, and after relocation or filter change. Do not exceed the maximum drug volume or use unapproved agents that would overwhelm the exhaust. Manage waste, sharps and spill kits according to the hazardous drug procedure, and keep a log of certification and decontamination.

How do I select the right Benchtop Cytotoxic Safety Cabinet?

Choose a benchtop unit for low-throughput, small-volume hazardous drug preparation where space is limited. Confirm the working height suits the vials and bags used. RFQ: drug list, vessel sizes, exhaust route, room pressure and certification type.

How does it compare with other Cytotoxic Cabinets variants?

Select the cabinet from the hazardous drug list, the required dose accuracy and the pharmacy's aseptic requirements. Use a Class II Type B2 cytotoxic cabinet with 100 % dedicated exhaust when volatile hazardous drugs are prepared. Choose a Compounding Aseptic Containment Isolator where the highest operator protection is needed and full isolation is acceptable, since glove access reduces dexterity. A Type A2 cytotoxic cabinet with canopy exhaust suits lower-risk drugs when recirculation is limited and local rules allow it. Confirm compatibility with USP <800> and USP <797> requirements, the pharmacy's risk assessment and any local rules on where the cabinet is placed, including a negative-pressure buffer room. Verify certification, plan for HEPA leak and containment testing, and specify the transfer method for drugs and waste.

Full specifications

Full specifications
Cabinet typeBenchtop cytotoxic Class II
Inflow velocity0.38–0.51 m/s
Downflow velocity0.25–0.35 m/s
Width900–1500 mm
Work height500–650 mm
HEPA gradeH14 supply and exhaust
ExhaustDucted or canopy
RecirculationMinimal or none
Work surfaceStainless steel 304
Noise level≤ 62 dB(A)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Satellite pharmacy compounding
  • Clinic and outpatient doses
  • Small-volume hazardous prep
  • Teaching and demonstration

Key features

  • Compact bench-mounted cabinet 900–1500 mm wide
  • Inflow 0.38–0.51 m/s and downflow 0.25–0.35 m/s
  • HEPA-filtered exhaust to duct or canopy
  • Airflow alarm and pressure gauge
  • Stainless work surface
  • Small-volume single-operator workflow

Frequently asked questions about Benchtop Cytotoxic Safety Cabinet

Internal height and volume. Large infusion bags, pumps or bulky devices may not fit under the sash, and throughput is lower, so it suits small satellite pharmacies rather than central units.

Request a quotation for the Benchtop Cytotoxic Safety Cabinet

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote