Light-Protected Chromatography Refrigerator for Photosensitive Standards — product photo

Light-Protected Chromatography Refrigerator for Photosensitive Standards

避光型层析冷藏箱(光敏标准品)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range2–8 °C
Net volume150–500 L
Temperature uniformity≤ 3 K
DoorSolid or UV-blocking tinted, lockable
Interior lightAmber or red LED, low intensity
Light transmission< 1% UV-A/visible through door (design target)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-011, IEC 61326-1

What is the Light-Protected Chromatography Refrigerator for Photosensitive Standards?

A 2–8 °C refrigerator with opaque or UV-filtered doors and amber interior lighting, for photosensitive reference standards, derivatisation reagents and samples. It prevents light-driven degradation of analytes during storage and retrieval, protecting the accuracy of HPLC, LC-MS and UV-based analyses that follow.

What is the Light-Protected Chromatography Refrigerator for Photosensitive Standards?

A 2–8 °C refrigerator with opaque or UV-filtered doors and amber interior lighting, for photosensitive reference standards, derivatisation reagents and samples. It prevents light-driven degradation of analytes during storage and retrieval, protecting the accuracy of HPLC, LC-MS and UV-based analyses that follow.

Overview

Some analytes, such as retinoids, riboflavin, nifedipine and many natural products, degrade under ultraviolet and short-wavelength visible light. This variant uses solid or UV-blocking tinted doors, and a low-intensity amber or red interior light, so that light exposure during retrieval is minimal. Volume is typically 150–500 L with shelves and drawers for amber vials and reagents. Forced-air control holds 2–8 °C, and optional data logging supports traceability of reference standards. Since light protection is only part of stability control, users should still keep analytes in amber or foil-wrapped containers and follow the standard's labelled storage. The cabinet is not intended for bulk flammable solvent storage, and it does not replace amber glassware, foil wrapping or the storage conditions stated on the reference standard's certificate.

How does it work?

A chromatography refrigerator uses a vapour-compression circuit and forced-air circulation, like any laboratory refrigerator, but the cabinet is configured around the workflow. Cold-cabinet versions include a work shelf, cable ports, internal sockets and lighting so that FPLC pumps, detectors and collectors operate inside at 4 °C. The controller holds the set point, usually within ±1 K, with airflow directed to avoid blowing across columns. Storage versions emphasise drawers, racks and locks for columns and standards. Light-protected versions use opaque doors and amber lighting, and variable-temperature versions add a heater and programmable profiles. The thermal design must handle door openings and the heat load of instruments inside the cabinet.

What are the key features?

  • Opaque or UV-blocking doors prevent light exposure during storage
  • Amber or red low-intensity interior light for retrieval
  • Shelves and drawers for amber vials and reference-standard boxes
  • Forced-air control at 2–8 °C with uniform temperature
  • Optional data logging for reference-standard traceability

What are the technical specifications?

A typical light-protected chromatography refrigerator for photosensitive standards configuration offers temperature range of 2–8 °C, net volume of 150–500 L, temperature uniformity of ≤ 3 K, door of Solid or UV-blocking tinted, lockable, interior light of Amber or red LED, low intensity and light transmission of < 1% UV-A/visible through door (design target). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Light-Protected Chromatography Refrigerator for Photosensitive Standards is used in reference-standard storage, photosensitive pharmaceutical analytes, vitamin and pigment analysis and LC-MS sample holding. Across the wider Chromatography Refrigerators class, laboratories also deploy it for protein purification at 4 °C, HPLC column storage and reference-standard storage.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-011, IEC 61326-1, ICH Q2(R2), NFPA 45, NFPA 30 and ISO 9001. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the cabinet on a level floor with the ventilation clearance stated in the manual, and size the electrical supply for the cabinet plus any instruments plugged into internal sockets. Allow the interior to reach set point before loading instruments. Condensation forms on cold surfaces when the door is open, so provide a drain or drip tray and keep electrical connections dry. Calibrate probes at least yearly, clean the condenser regularly, and check gaskets. For regulated work, document temperature mapping and record temperature so that run conditions can be shown in method records.

How do I select the right Light-Protected Chromatography Refrigerator for Photosensitive Standards?

Choose this variant when your standards and samples are documented as photosensitive. Specify volume, door type, interior light colour and data output. Standard cabinets with amber vials are often enough for modest needs, while this variant reduces risk when frequent access or long storage is involved.

How does it compare with other Chromatography Refrigerators variants?

Decide first whether the cabinet will run instruments or only store consumables. For instruments, specify internal dimensions, total heat load, cable ports, sockets and door type, and choose a large cabinet for several systems. For consumables, an undercounter model with drawers is enough. Choose a light-protected model for photosensitive standards and a variable-temperature model for methods with multiple temperatures. Compare temperature uniformity, noise, condensation control and alarms. Confirm ambient range, power supply and floor loading. Never place open flammable solvents in a standard unit, and choose a flammable-storage or explosion-proof model where solvents are stored.

Full specifications

Full specifications
Temperature range2–8 °C
Net volume150–500 L
Temperature uniformity≤ 3 K
DoorSolid or UV-blocking tinted, lockable
Interior lightAmber or red LED, low intensity
Light transmission< 1% UV-A/visible through door (design target)
Cooling methodForced-air circulation
RefrigerantR600a or R290
Data outputUSB or RS-485 (optional)
Power supply220–240 V, 50 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Reference-standard storage
  • Photosensitive pharmaceutical analytes
  • Vitamin and pigment analysis
  • LC-MS sample holding

Key features

  • Opaque or UV-blocking doors prevent light exposure during storage
  • Amber or red low-intensity interior light for retrieval
  • Shelves and drawers for amber vials and reference-standard boxes
  • Forced-air control at 2–8 °C with uniform temperature
  • Optional data logging for reference-standard traceability

Frequently asked questions about Light-Protected Chromatography Refrigerator for Photosensitive Standards

Examples include retinoids, riboflavin, nifedipine, curcumin, tetracyclines and some carotenoids. Check the standard's certificate or pharmacopoeial monograph, which often states to protect from light, and use amber glassware along with light-protected storage.

Request a quotation for the Light-Protected Chromatography Refrigerator for Photosensitive Standards

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote