Convertible Chest Freezer-Refrigerator with Selectable Temperature
可切换温度的卧式冷冻冷藏两用箱
- SKU CHF-0005
- Chest Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -25 to +10 °C, selectable |
|---|---|
| Net capacity | 150-500 L |
| Refrigerator mode setpoint | 2-8 °C |
| Freezer mode setpoint | -10 to -25 °C |
| Cooling method | Direct cooling |
| Defrost | Manual or programmable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ISO 23953
What is the Convertible Chest Freezer-Refrigerator with Selectable Temperature?
A chest cabinet with a selectable temperature setting from about -25 °C to +10 °C, letting one unit serve as a freezer or a refrigerator. It gives laboratories flexible bulk storage for changing sample types and seasonal workloads.
What is the Convertible Chest Freezer-Refrigerator with Selectable Temperature?
A chest cabinet with a selectable temperature setting from about -25 °C to +10 °C, letting one unit serve as a freezer or a refrigerator. It gives laboratories flexible bulk storage for changing sample types and seasonal workloads.
Overview
The convertible chest unit adds a wide-range controller and a compressor and evaporator sized for operation from -25 °C to +10 °C. Users select a freezer mode for frozen stock or a refrigerator mode at 2 to 8 °C for reagents, vaccines or food samples. Capacity typically ranges from 150 to 500 L. In refrigerator mode, the evaporator is regulated to avoid frost on the contents, and a defrost cycle can be programmed. It offers flexibility where demand shifts, for example during sampling campaigns or outbreak responses, and serves as an emergency spare for either type of storage. It does not match the uniformity of a dedicated pharmacy refrigerator at 2 to 8 °C, so regulated vaccine storage requires a purpose-built unit.
How does it work?
A chest freezer uses the same vapor-compression cycle as other laboratory freezers, but its geometry changes heat exchange. The cabinet opens from the top, and because cold air is denser than warm air it sits in the well when the lid is lifted, so little warm air enters and temperature recovers quickly. Evaporator tubes are usually bonded to the inner walls, which provides direct cooling without fans, reducing energy use and air movement over samples. The lid and walls are filled with polyurethane foam of 70 to 150 mm, and a magnetic or compression gasket seals the rim. Models for -20 to -40 °C use a single compressor, while models for -60 to -86 °C use cascade or mixed-refrigerant systems. Controllers monitor temperature, alarm on deviation and door ajar, and many include lid locks, drain ports and a pressure-equalization valve.
What are the key features?
- Selectable setpoint from about -25 to +10 °C with one controller.
- Freezer mode and 2 to 8 °C refrigerator mode in the same cabinet.
- Programmable defrost cycle in refrigerator mode.
- Serves as emergency spare for either freezer or refrigerator duty.
- Removable baskets and lockable lid.
- High and low temperature alarms adjust to the selected mode.
What are the technical specifications?
A typical convertible chest freezer-refrigerator with selectable temperature configuration offers temperature range of -25 to +10 °C, selectable, net capacity of 150-500 L, refrigerator mode setpoint of 2-8 °C, freezer mode setpoint of -10 to -25 °C, cooling method of Direct cooling and defrost of Manual or programmable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Convertible Chest Freezer-Refrigerator with Selectable Temperature is used in flexible bulk storage, sampling campaign stock, emergency spare cold storage and food and environmental sample holding. Across the wider Chest Freezers class, laboratories also deploy it for bulk plasma and tissue storage, long-term biobank archives and food and environmental retained samples.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ISO 23953, ENERGY STAR Laboratory Grade Freezers, EN 15713 and GB/T 21151. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the freezer on a level floor with 100 to 200 mm of clearance around the cabinet and enough headroom for the lid to open fully. Keep room temperature below the rated ambient, usually 32 °C, and avoid direct sunlight or nearby heat sources. Use a dedicated circuit with surge protection. Organize contents with baskets and a location map so that the lid is open as briefly as possible. Direct-cooling models accumulate frost on the walls, so schedule defrosting when the layer reaches 5 to 10 mm, transferring contents to a backup unit. Clean the condenser every one to three months, check the gasket seal and calibrate the temperature display at least annually. Test the alarm and lid lock regularly.
How do I select the right Convertible Chest Freezer-Refrigerator with Selectable Temperature?
Select the convertible unit when storage needs change between frozen and chilled, or as a spare. Dedicated units are preferable for regulated vaccine or plasma storage. Specify the temperature range, uniformity requirement, defrost method, lid lock and alarm outputs.
How does it compare with other Chest Freezers variants?
Choose a chest freezer when samples are stored in bulk, accessed infrequently and held for long periods. Start with the temperature class, from -20 °C for reagents to -86 °C for long-term archives. Then size the capacity from the inventory, remembering that usable volume depends on baskets and that items at the bottom are harder to reach. Compare daily energy consumption, since chest models are usually more efficient than upright units of the same volume. Consider the footprint and lid clearance, because a chest freezer needs free space above it when open. Look for features that matter to your quality system, including alarms, lid lock, data logging, backup ports and temperature uniformity. For frequent access or strong organization needs, an upright unit may be more practical.
Full specifications
| Temperature range | -25 to +10 °C, selectable |
|---|---|
| Net capacity | 150-500 L |
| Refrigerator mode setpoint | 2-8 °C |
| Freezer mode setpoint | -10 to -25 °C |
| Cooling method | Direct cooling |
| Defrost | Manual or programmable |
| Ambient rating | 10-32 °C |
| Temperature uniformity | Within ±5 °C in freezer mode |
| Lid lock | Key lock |
| Power consumption | About 1.5-4 kWh/day |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Flexible bulk storage
- Sampling campaign stock
- Emergency spare cold storage
- Food and environmental sample holding
Key features
- Selectable setpoint from about -25 to +10 °C with one controller.
- Freezer mode and 2 to 8 °C refrigerator mode in the same cabinet.
- Programmable defrost cycle in refrigerator mode.
- Serves as emergency spare for either freezer or refrigerator duty.
- Removable baskets and lockable lid.
- High and low temperature alarms adjust to the selected mode.
Frequently asked questions about Convertible Chest Freezer-Refrigerator with Selectable Temperature
It can hold that range, but uniformity and recovery are usually weaker than in a purpose-built pharmacy refrigerator. For regulated vaccine storage, use a dedicated qualified unit.
Changing the setpoint is immediate, but the cabinet needs several hours to reach the new temperature, and frozen contents should not be moved into refrigerator mode without planning.
On most models the alarm limits are set relative to the selected setpoint, but you should check and adjust them after changing modes so that alarms match your procedure.
It stores reagents, plasma, tissue, samples and archives in bulk, at temperatures from -20 °C to -86 °C. The top-opening design holds temperature well, so it suits material that is accessed only occasionally.
It is better for energy use, temperature stability and bulk storage, while an upright is better for organization and quick access. The right choice depends on how often samples are retrieved.
Use stackable baskets or dividers, label them by lot and date, and keep a digital map of positions. Put frequently needed items on top so that the lid is open for as short a time as possible.