Chest -40 °C Biomedical Freezer
卧式 -40 °C 生物医学冷冻箱
- SKU CHF-0002
- Chest Freezers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-2-011 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -25 to -45 °C |
|---|---|
| Net capacity | 100-500 L |
| Cooling method | Direct cooling |
| Insulation thickness | 100-120 mm polyurethane |
| Display resolution | 0.1 °C |
| Ambient rating | 10-32 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ISO 23953
What is the Chest -40 °C Biomedical Freezer?
A chest freezer for -25 to -45 °C storage with capacities of 100 to 500 L. It is used for bulk plasma, tissue and buffers that need colder conditions than -20 °C, with better uniformity and stronger alarms than general-purpose units.
What is the Chest -40 °C Biomedical Freezer?
A chest freezer for -25 to -45 °C storage with capacities of 100 to 500 L. It is used for bulk plasma, tissue and buffers that need colder conditions than -20 °C, with better uniformity and stronger alarms than general-purpose units.
Overview
The chest -40 °C biomedical freezer is built for bulk storage of material that must stay below -30 °C. A higher-capacity compressor and thicker insulation of 100 to 120 mm give a larger temperature lift, and the lid is fitted with double gaskets and a heater frame to limit condensation. The controller reads a platinum resistance sensor with 0.1 °C resolution and drives independent high and low alarms, lid-ajar warning and power-failure alarm with battery backup. Typical uses include fresh frozen plasma stocks, tissue specimens, and stability storage. Energy use is about 2 to 5 kWh daily. Because it is a chest format, temperature recovers quickly after the lid is opened, but organization with baskets and a location map is important to keep open time short.
How does it work?
A chest freezer uses the same vapor-compression cycle as other laboratory freezers, but its geometry changes heat exchange. The cabinet opens from the top, and because cold air is denser than warm air it sits in the well when the lid is lifted, so little warm air enters and temperature recovers quickly. Evaporator tubes are usually bonded to the inner walls, which provides direct cooling without fans, reducing energy use and air movement over samples. The lid and walls are filled with polyurethane foam of 70 to 150 mm, and a magnetic or compression gasket seals the rim. Models for -20 to -40 °C use a single compressor, while models for -60 to -86 °C use cascade or mixed-refrigerant systems. Controllers monitor temperature, alarm on deviation and door ajar, and many include lid locks, drain ports and a pressure-equalization valve.
What are the key features?
- Higher-capacity compressor and 100 to 120 mm insulation hold -40 °C.
- Double lid gaskets and heater frame limit condensation and sticking.
- Platinum resistance sensor with 0.1 °C display resolution.
- Independent alarms for high and low temperature, lid ajar and power failure.
- Battery-backed alarm continues during mains loss.
- Removable baskets organize bulk plasma bags or boxes.
What are the technical specifications?
A typical chest -40 °c biomedical freezer configuration offers temperature range of -25 to -45 °C, net capacity of 100-500 L, cooling method of Direct cooling, insulation thickness of 100-120 mm polyurethane, display resolution of 0.1 °C and ambient rating of 10-32 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Chest -40 °C Biomedical Freezer is used in fresh frozen plasma bulk storage, tissue specimen storage, stability sample storage and buffer and reagent stock. Across the wider Chest Freezers class, laboratories also deploy it for bulk plasma and tissue storage, long-term biobank archives and food and environmental retained samples.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ISO 23953, ENERGY STAR Laboratory Grade Freezers, EN 15713 and GB/T 21151. Certification candidates for this model are CE, ISO 13485 manufacturing and IEC 61010-2-011 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the freezer on a level floor with 100 to 200 mm of clearance around the cabinet and enough headroom for the lid to open fully. Keep room temperature below the rated ambient, usually 32 °C, and avoid direct sunlight or nearby heat sources. Use a dedicated circuit with surge protection. Organize contents with baskets and a location map so that the lid is open as briefly as possible. Direct-cooling models accumulate frost on the walls, so schedule defrosting when the layer reaches 5 to 10 mm, transferring contents to a backup unit. Clean the condenser every one to three months, check the gasket seal and calibrate the temperature display at least annually. Test the alarm and lid lock regularly.
How do I select the right Chest -40 °C Biomedical Freezer?
Select this variant for bulk material that must stay below -30 °C with documented alarms. Choose an upright -40 °C unit for frequent access. In an RFQ give net volume, target temperature, alarm outputs, battery duration, lid lock and data logging.
How does it compare with other Chest Freezers variants?
Choose a chest freezer when samples are stored in bulk, accessed infrequently and held for long periods. Start with the temperature class, from -20 °C for reagents to -86 °C for long-term archives. Then size the capacity from the inventory, remembering that usable volume depends on baskets and that items at the bottom are harder to reach. Compare daily energy consumption, since chest models are usually more efficient than upright units of the same volume. Consider the footprint and lid clearance, because a chest freezer needs free space above it when open. Look for features that matter to your quality system, including alarms, lid lock, data logging, backup ports and temperature uniformity. For frequent access or strong organization needs, an upright unit may be more practical.
Full specifications
| Temperature range | -25 to -45 °C |
|---|---|
| Net capacity | 100-500 L |
| Cooling method | Direct cooling |
| Insulation thickness | 100-120 mm polyurethane |
| Display resolution | 0.1 °C |
| Ambient rating | 10-32 °C |
| Pull-down time | Under 6 h from 25 °C to -40 °C, empty |
| Alarm battery backup | 12 h or longer |
| Temperature uniformity | Within ±6 °C at steady state |
| Power consumption | About 2-5 kWh/day |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Fresh frozen plasma bulk storage
- Tissue specimen storage
- Stability sample storage
- Buffer and reagent stock
Key features
- Higher-capacity compressor and 100 to 120 mm insulation hold -40 °C.
- Double lid gaskets and heater frame limit condensation and sticking.
- Platinum resistance sensor with 0.1 °C display resolution.
- Independent alarms for high and low temperature, lid ajar and power failure.
- Battery-backed alarm continues during mains loss.
- Removable baskets organize bulk plasma bags or boxes.
Frequently asked questions about Chest -40 °C Biomedical Freezer
Yes for most blood service standards, which require -25 °C or colder, with -30 °C or lower often used. Follow the rules of your national blood authority or accreditation body.
At low temperatures, moisture condenses and freezes around the lid rim, which can bond the gasket to the cabinet. A heater frame keeps the rim above freezing so the lid opens easily.
By placing calibrated probes at multiple positions in a loaded cabinet and recording the spread once steady state is reached. Request the maker's test data or perform mapping on site.
It stores reagents, plasma, tissue, samples and archives in bulk, at temperatures from -20 °C to -86 °C. The top-opening design holds temperature well, so it suits material that is accessed only occasionally.
It is better for energy use, temperature stability and bulk storage, while an upright is better for organization and quick access. The right choice depends on how often samples are retrieved.
Use stackable baskets or dividers, label them by lot and date, and keep a digital map of positions. Put frequently needed items on top so that the lid is open for as short a time as possible.