Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing — product photo

Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing

用于常规氮-蛋白质检测的台式 CHN 分析仪

  • SKU CHA-0005
  • CHNS Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Elements measuredN (C, H optional)
Sample mass100 mg–1 g
Nitrogen range0.02–50 mg absolute N
Nitrogen repeatability (RSD)≤0.5% (EDTA standard)
Combustion temperature950–1000 °C
Analysis time3–5 min per sample
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D5373, ISO 29541, ASTM D5291

What is the Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing?

A benchtop CHN analyzer for nitrogen-protein testing uses the Dumas combustion method to determine total nitrogen and convert it to crude protein. It replaces Kjeldahl digestion in food, feed, and agricultural laboratories that need fast, chemical-free results. Typical throughput exceeds fifty samples daily.

What is the Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing?

A benchtop CHN analyzer for nitrogen-protein testing uses the Dumas combustion method to determine total nitrogen and convert it to crude protein. It replaces Kjeldahl digestion in food, feed, and agricultural laboratories that need fast, chemical-free results. Typical throughput exceeds fifty samples daily.

Overview

This variant is configured for high-throughput total nitrogen determination using the Dumas method. A 100 mg to 1 g sample is combusted in oxygen at about 950–1000 °C, gases are cleaned of water and CO2 by traps, nitrogen oxides are reduced to N2 over copper, and N2 is measured by a thermal conductivity detector. Crude protein is calculated using a matrix-specific factor, for example 6.25 for general foods or 5.7 for wheat. Run time is about 3–5 minutes, with autosamplers holding 40–100 positions, and no hazardous chemicals such as sulfuric acid or catalysts are used. Carbon and hydrogen channels may be included for energy or fat estimation. Compared with Kjeldahl, the method is faster and automated, but nitrogen from non-protein sources is counted, so conversion factors and method validation against reference materials are required.

How does it work?

A CHNS analyzer drops a weighed sample of 1–10 mg, sealed in a tin capsule, into a combustion reactor held at roughly 950–1150 °C while a timed oxygen pulse is injected. The tin oxidizes exothermically and lifts the local temperature to about 1800 °C, converting the sample to CO2, H2O, N2, nitrogen oxides, and SO2. A helium carrier gas sweeps these products through a reduction zone of hot copper, which converts nitrogen oxides to N2 and removes excess oxygen. Water traps or a chromatographic column then separate the gases. A thermal conductivity detector measures each in turn and the software integrates peak areas against a calibration with a standard such as acetanilide or sulfanilamide. Oxygen mode uses pyrolysis over nickel-coated carbon to form CO.

What are the key features?

  • Dumas combustion replaces Kjeldahl digestion with no hazardous acids or catalysts.
  • Run time of 3–5 minutes per sample supports high-volume food and feed laboratories.
  • Sample capacity from 100 mg to 1 g improves representativeness for grains and feeds.
  • Software applies configurable protein conversion factors per product type.
  • Autosampler with 40–100 positions enables unattended operation for routine batches.

What are the technical specifications?

A typical benchtop chn analyzer for routine nitrogen-protein testing configuration offers elements measured of N (C, H optional), sample mass of 100 mg–1 g, nitrogen range of 0.02–50 mg absolute N, nitrogen repeatability (RSD) of ≤0.5% (EDTA standard), combustion temperature of 950–1000 °C and analysis time of 3–5 min per sample. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing is used in food protein labelling, animal feed and pet food testing, grain and oilseed trading laboratories and fertilizer total nitrogen. Across the wider CHNS Analyzers class, laboratories also deploy it for organic synthesis and purity confirmation, pharmaceutical raw material QC and polymer and battery material composition.

Which standards and certifications apply?

Relevant standards and methods include ASTM D5373, ISO 29541, ASTM D5291, ASTM E1019, USP <233>, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install in a draft-free room with stable temperature and a vibration-free bench for the microbalance. Helium of 99.999% purity and oxygen of 99.995% purity are typical, and gas leaks are the most common cause of drift. Calibrate with a certified standard in multiple weights and run blanks and conditioning samples at the start of each day. Replace the combustion tube packing, reduction copper, and water trap on a schedule based on sample count, usually every 300–1000 samples. Halogenated and high-ash samples consume consumables faster and may need additives such as vanadium pentoxide. Laboratories under GLP or ISO/IEC 17025 should record system suitability using check standards and keep balance calibration records.

How do I select the right Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing?

Select this variant when the primary task is nitrogen or protein with sample masses of 100 mg to 1 g and throughput over 50 samples per day. It is not for micro organic formula confirmation. Specify the nitrogen range, conversion factors, autosampler capacity, and whether AOAC 992.15 or ISO 16634 method support is required.

How does it compare with other CHNS Analyzers variants?

The main decision is the set of elements and the sample type. A CHN configuration suits most organic synthesis work, while CHNS adds a sulfur channel and requires a column able to resolve SO2. Add oxygen pyrolysis if O is required. Microbalance resolution governs precision for small samples, so specify 0.001 mg for 1–2 mg weighing. Autosampler capacity of 50–120 positions matters for routine throughput. Liquid and volatile samples need sealed capsules or a liquid-capable module. Large-sample and heterogeneous materials such as soil, coal, and biomass benefit from macro analyzers handling 100 mg to several grams. Check whether the vendor documents accuracy, typically within 0.3% absolute of theoretical values for pure standards, and whether the software supports 21 CFR Part 11 style audit trails if used in regulated laboratories.

Full specifications

Full specifications
Elements measuredN (C, H optional)
Sample mass100 mg–1 g
Nitrogen range0.02–50 mg absolute N
Nitrogen repeatability (RSD)≤0.5% (EDTA standard)
Combustion temperature950–1000 °C
Analysis time3–5 min per sample
Carrier gasHelium or argon
Autosampler capacity40–100 positions
Protein factorUser-defined, e.g. 6.25
DetectorThermal conductivity detector

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Food protein labelling
  • Animal feed and pet food testing
  • Grain and oilseed trading laboratories
  • Fertilizer total nitrogen

Key features

  • Dumas combustion replaces Kjeldahl digestion with no hazardous acids or catalysts.
  • Run time of 3–5 minutes per sample supports high-volume food and feed laboratories.
  • Sample capacity from 100 mg to 1 g improves representativeness for grains and feeds.
  • Software applies configurable protein conversion factors per product type.
  • Autosampler with 40–100 positions enables unattended operation for routine batches.

Frequently asked questions about Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing

Yes, for many matrices. AOAC 992.15 and ISO 16634 recognize combustion nitrogen methods for meat, cereals, and oilseeds. The instrument must be validated against reference materials and the method accepted by your regulator or customer before replacing Kjeldahl results.

Related models

All CHNS Analyzers

Request a quotation for the Benchtop CHN Analyzer for Routine Nitrogen-Protein Testing