Skip to main content
Lab Manufacturers China
Tissue Dissociation System — product photo

Tissue Dissociation System

组织解离系统

  • SKU CEP-0003
  • Cell Processing
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Throughput1–8 samples per run
Tissue mass per sampleup to approx. 1 g
Temperature control37 °C, within ±0.5 °C
Digestion timeapprox. 15–60 min
Mechanical actionRotating paddle, rotor or moving fluid
Cell yield10⁶–10⁸ depending on tissue
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61010-2-020

What is the Tissue Dissociation System?

A tissue dissociation system combines enzymatic digestion with controlled mechanical shear to convert solid tissue into a single-cell suspension with high viability and preserved surface markers for flow cytometry, culture or sequencing.

What is the Tissue Dissociation System?

A tissue dissociation system combines enzymatic digestion with controlled mechanical shear to convert solid tissue into a single-cell suspension with high viability and preserved surface markers for flow cytometry, culture or sequencing.

Overview

Tissues are minced, then digested with enzymes selected for the matrix: collagenase for connective tissue, dispase for epithelium, trypsin for some solid organs, and papain with DNase for neural tissue. The instrument supplies gentle heating, agitation and intermittent shear through a rotor, a paddle or a closed chamber with moving fluid, so digestion proceeds evenly and cells are released without excessive damage. Temperature is held at 37 °C and the run is stopped when the suspension appears homogeneous, which is often monitored by observing the sample through a window. DNase is included to prevent released DNA from causing clumping. Typical protocols take 15–60 minutes and yield 10⁶–10⁸ cells depending on tissue mass, with viability above 85% for well-optimised conditions.

How does it work?

Each processing step addresses a different physical or biological barrier. Electroporation applies a brief electric pulse that transiently increases membrane permeability so plasmid DNA, RNA or protein can enter the cytoplasm or nucleus; efficiency depends on field strength, pulse shape and buffer conductivity. Thawing instruments warm frozen vials under controlled heat transfer so that cells pass quickly through the temperature range where ice recrystallisation damages membranes. Tissue dissociation combines enzymatic digestion with controlled mechanical shear, using a heater-shaker, a gentleMACS-style rotor or a closed automated chamber, to release single cells while limiting DNA release that causes clumping. Media exchange systems centrifuge, resuspend and wash cells in a closed circuit for concentration and formulation. Vibrating microtomes cut living tissue into slices with minimal damage, preserving neural circuitry for electrophysiology and explant culture.

What are the key features?

  • Heating and agitation with controlled intermittent shear
  • Rotor or paddle mechanisms for gentle mechanical dissociation
  • Closed chamber option for sterile or contained processing
  • Temperature held at 37 °C with ±0.5 °C stability
  • DNase-compatible protocols to prevent clumping
  • Observation window or sampling port to monitor digestion

What are the technical specifications?

A typical tissue dissociation system configuration offers throughput of 1–8 samples per run, tissue mass per sample of up to approx. 1 g, temperature control of 37 °C, within ±0.5 °C, digestion time of approx. 15–60 min, mechanical action of Rotating paddle, rotor or moving fluid and cell yield of 10⁶–10⁸ depending on tissue. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Tissue Dissociation System is used in tumour tissue dissociation for single-cell analysis, neural tissue dissociation for culture, organoid and stem cell isolation and tissue digestion for flow cytometry panels. Across the wider Cell Processing class, laboratories also deploy it for transfection of primary cells and cell lines, recovery of cryopreserved cell stocks and primary tissue dissociation for cell culture.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61010-2-020, ISO 20387, USP <1046> and ISO 13485. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Keep consumables sterile and single-use where possible, and use aseptic technique for anything that will be cultured. Electroporation cuvettes must be clean and the buffer free of salts that cause arcing; verify pulse delivery by checking the time constant, and monitor temperature because excessive Joule heating kills cells. Dissociation protocols should be stopped as soon as single cells are released, since prolonged enzyme exposure cleaves surface antigens and reduces viability. Cells are sensitive to repeated centrifugation, so minimise steps and use gentle speeds. Validate each new protocol against a reference method, recording recovery, viability and marker expression, and check the quality of tissue slicing with a viability stain such as calcein AM. Maintain temperature-controlled equipment within tolerance and document calibration.

How do I select the right Tissue Dissociation System?

Select a tissue dissociation system when reproducible single-cell suspensions are needed from solid tissue with preserved surface markers. Specify throughput, tissue mass, temperature stability, chamber type, protocol library and whether a closed system is required for sterility or containment.

How does it compare with other Cell Processing variants?

Choose by the cell type and the downstream assay. For transfection, compare electroporation with chemical or lipid methods: electroporation suits hard-to-transfect primary cells and suspension lines but needs optimisation of pulse conditions and cell numbers. For tissue work, decide between enzymatic digestion with mechanical shear for solid tissue and gentler dissociation when surface markers or viability are critical. For neural tissue, vibrating microtomes and automated slicers preserve viability better than blade homogenisation. Thawing and media exchange instruments should be selected for closed processing, traceability and reproducibility between operators when regulated workflows are involved. Across all of these, the decisive parameters are sheared-cell percentage, recovery, viability, sterility, sample capacity and the availability of validated protocols for your specific cell type.

Full specifications

Full specifications
Throughput1–8 samples per run
Tissue mass per sampleup to approx. 1 g
Temperature control37 °C, within ±0.5 °C
Digestion timeapprox. 15–60 min
Mechanical actionRotating paddle, rotor or moving fluid
Cell yield10⁶–10⁸ depending on tissue
Viabilityabove 85% for optimised protocols
Chamber typeOpen tube or closed single-use chamber
Program memoryMultiple validated protocols
Dimensions (W x D x H)approx. 300 x 350 x 300 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Tumour tissue dissociation for single-cell analysis
  • Neural tissue dissociation for culture
  • Organoid and stem cell isolation
  • Tissue digestion for flow cytometry panels

Key features

  • Heating and agitation with controlled intermittent shear
  • Rotor or paddle mechanisms for gentle mechanical dissociation
  • Closed chamber option for sterile or contained processing
  • Temperature held at 37 °C with ±0.5 °C stability
  • DNase-compatible protocols to prevent clumping
  • Observation window or sampling port to monitor digestion

Frequently asked questions about Tissue Dissociation System

Use collagenase for connective tissue rich organs such as mammary gland or lung, dispase for epithelial tissue, trypsin or accutase for many cultured or embryonic tissues, and papain with DNase for neural tissue. Optimal combinations are established empirically for each tissue type.

Related models

All Cell Processing

Request a quotation for the Tissue Dissociation System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote