Dual-Chamber BOD Incubator — product photo

Dual-Chamber BOD Incubator

双腔体 BOD 培养箱

  • SKU BOI-0004
  • BOD Incubators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Volume per chamber150–300 L
Chambers2
Temperature range0–60 C per chamber
Temperature uniformity±0.5–1 C
Temperature stability±0.5 C
Bottle capacity60–120 per chamber
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880

What is the Dual-Chamber BOD Incubator?

A dual-chamber BOD incubator has two independently controlled compartments in one cabinet. It is chosen to run separate batches at different temperatures or to isolate samples while saving valuable floor space in a crowded laboratory.

What is the Dual-Chamber BOD Incubator?

A dual-chamber BOD incubator has two independently controlled compartments in one cabinet. It is chosen to run separate batches at different temperatures or to isolate samples while saving valuable floor space in a crowded laboratory.

Overview

The dual-chamber incubator stacks two refrigerated compartments in one cabinet, each with its own controller, door and cooling, so they can run at different temperatures or hold separate batches. This is useful when BOD tests at 20 C must run alongside samples at another temperature, or when one batch must not be disturbed while another is loaded. Each chamber reaches about 0 to 60 C with uniformity of plus or minus 0.5 to 1 C and defrost managed separately, so a cycle in one chamber does not affect the other. Volumes are typically 150 to 300 liters per chamber. Shared cabinet construction saves floor space, but ventilation and heat rejection must handle both chambers together.

How does it work?

A BOD incubator maintains a fixed setpoint, commonly 20 C, with compressor refrigeration and heating under PID control, so it holds temperature whether the room is warmer or cooler. Forced-air circulation keeps uniformity within plus or minus 0.5 to 1 C across the chamber, and a door heater or heated frame prevents condensation at the fixed low temperature. The interior is dark, since light can affect samples and encourage algae, and shelves or racks hold BOD bottles or other vessels. Defrost cycles are scheduled to avoid temperature excursions during the five-day test, and many models include a timer or chart for the incubation period. Alarms warn of temperature deviation, and some units log temperature continuously so a valid test can be demonstrated.

What are the key features?

  • Two independently controlled compartments
  • Separate controller, door and cooling per chamber
  • Different setpoints and batches in one cabinet
  • Uniformity of ±0.5 to 1 C per chamber
  • Independent defrost scheduling
  • Shared cabinet saving floor space

What are the technical specifications?

A typical dual-chamber bod incubator configuration offers volume per chamber of 150–300 L, chambers of 2, temperature range of 0–60 C per chamber, temperature uniformity of ±0.5–1 C, temperature stability of ±0.5 C and bottle capacity of 60–120 per chamber. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dual-Chamber BOD Incubator is used in parallel BOD batches at one temperature, BOD alongside another incubation temperature, sample isolation between batches and laboratories short of floor space. Across the wider BOD Incubators class, laboratories also deploy it for five-day BOD determination in water and wastewater, biochemical oxygen demand method training and influent and effluent monitoring.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, APHA 5210, ISO 5815-1 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the incubator in a ventilated location with clearance for the condenser and door swing, away from heat sources and direct sunlight. Keep the interior dark and do not open the door during the incubation other than at defined checkpoints, since temperature recovery may alter the result. Verify the temperature at the working setpoint with a calibrated probe, and log it continuously where the method requires evidence. Clean spills promptly and disinfect as needed, taking care not to scratch the interior or leave residues that affect samples. Check the condenser, gaskets and door heater during scheduled service, and record all maintenance.

How do I select the right Dual-Chamber BOD Incubator?

Select the dual-chamber incubator when two independent temperature batches must run in one place, or when floor space is limited but capacity must still grow. Single-chamber models cost less if one condition is enough. In the RFQ, specify volume per chamber, setpoints, bottle capacity, defrost and logging.

How does it compare with other BOD Incubators variants?

Choose a BOD incubator when a method specifies incubation at a fixed low temperature, most often the 20 C five-day BOD test, and when the laboratory needs to show that temperature was held. Set the required temperature and tolerance, then check uniformity at that point rather than a midpoint. Match chamber volume to bottle count and to the use of racks or shelves. Confirm defrost behaviour, since ice build-up or regular defrost cycles can disturb the incubation. Decide whether programmable control, dual chambers or temperature logging are needed for compliance. Check door type, alarms, data output and refrigerant type before ordering.

Full specifications

Full specifications
Volume per chamber150–300 L
Chambers2
Temperature range0–60 C per chamber
Temperature uniformity±0.5–1 C
Temperature stability±0.5 C
Bottle capacity60–120 per chamber
Cooling systemCompressor, air-cooled
DefrostIndependent per chamber
Cooling power500 W–1.5 kW total
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Parallel BOD batches at one temperature
  • BOD alongside another incubation temperature
  • Sample isolation between batches
  • Laboratories short of floor space

Key features

  • Two independently controlled compartments
  • Separate controller, door and cooling per chamber
  • Different setpoints and batches in one cabinet
  • Uniformity of ±0.5 to 1 C per chamber
  • Independent defrost scheduling
  • Shared cabinet saving floor space

Frequently asked questions about Dual-Chamber BOD Incubator

Yes. Each chamber has its own controller and cooling, so one can hold 20 C for BOD while the other runs at another setpoint. This lets a laboratory run different methods side by side without a second cabinet.