Blood Bank Refrigerator with Remote Temperature Monitoring
带远程温度监控的血库冷藏箱
- SKU BBR-0003
- Blood Bank Refrigerators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 2–6 °C, set point 4 °C |
|---|---|
| Net volume | 300–1000 L |
| Temperature uniformity | ≤ 2 K |
| Connectivity | Ethernet, Wi-Fi, RS-485 or GSM |
| Notification | SMS, email, relay output |
| Data logging interval | 1–10 min, adjustable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, ISO 15189
What is the Blood Bank Refrigerator with Remote Temperature Monitoring?
A blood bank refrigerator with networked sensors that send temperature data and alarms to a central dashboard, phone or email. It suits hospitals and laboratories that operate several cabinets, run unattended overnight, or need secure electronic audit trails.
What is the Blood Bank Refrigerator with Remote Temperature Monitoring?
A blood bank refrigerator with networked sensors that send temperature data and alarms to a central dashboard, phone or email. It suits hospitals and laboratories that operate several cabinets, run unattended overnight, or need secure electronic audit trails.
Overview
In this variant the cabinet electronics publish temperature, door status and alarm state through Ethernet, Wi-Fi, RS-485 or a GSM module. Software consolidates data from several refrigerators, freezers and incubators into one view with user-level access control, an audit trail and exportable reports. Escalation rules notify staff by SMS, email or an on-call system if temperature leaves the 2–6 °C band. The local cabinet still carries its own display and audible alarm, so it remains safe if the network drops. Sensor data is time-stamped, and the software keeps logs for the retention period required. Validation should cover the monitoring chain, including alarm delivery and data integrity, in addition to the refrigerator performance itself.
How does it work?
A laboratory blood bank refrigerator uses a vapour-compression circuit with forced-air circulation to hold a narrow temperature band. The cabinet has PU insulation, ducted shelves and a microprocessor controller that reads a control probe and cycles the compressor. A second, independent probe, often buffered in glycol, drives a separate alarm circuit with battery backup so that a control failure cannot go unnoticed. A chart recorder or electronic logger produces a continuous record. Air ducting and fan placement minimise cold spots near the evaporator to avoid freezing red cells and haemolysis. Units for samples and reagents can use a simpler undercounter design, while those for transfusion units need tighter uniformity, recording and validated alarm performance.
What are the key features?
- Networked temperature, door and alarm data through Ethernet, Wi-Fi or GSM
- Central dashboard consolidates several cabinets with audit trail
- Escalation by SMS or email when temperature leaves the 2–6 °C band
- Local display and audible alarm continue working if the network fails
- Time-stamped data exportable for inspection and quality review
What are the technical specifications?
A typical blood bank refrigerator with remote temperature monitoring configuration offers temperature range of 2–6 °C, set point 4 °C, net volume of 300–1000 L, temperature uniformity of ≤ 2 K, connectivity of Ethernet, Wi-Fi, RS-485 or GSM, notification of SMS, email, relay output and data logging interval of 1–10 min, adjustable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Blood Bank Refrigerator with Remote Temperature Monitoring is used in multi-cabinet blood banks, unattended overnight storage, regional transfusion centres and inspection and audit readiness. Across the wider Blood Bank Refrigerators class, laboratories also deploy it for retained patient samples, red cell storage and transfusion reagents.
Which standards and certifications apply?
Relevant standards and methods include AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, ISO 15189, IEC 61010-2-011 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a level floor with the clearance stated in the manual, away from heat sources, and allow the cabinet to stabilise before loading. Perform installation, operational and performance qualification, including temperature mapping and alarm challenge tests, and repeat after relocation or major repair. Calibrate probes and recorders at least yearly against traceable references. Clean condensers, check gaskets and test battery backups on schedule. Keep records of temperatures, alarms and corrective actions as required by your accreditation body and transfusion regulator.
How do I select the right Blood Bank Refrigerator with Remote Temperature Monitoring?
Choose the remote-monitoring variant when several cabinets must be watched centrally or when staffing is limited overnight. Specify network type, notification methods, user access rules, software validation documents and data retention period. Confirm that your information-technology team supports the required security and network configuration, and ask for software validation documents.
How does it compare with other Blood Bank Refrigerators variants?
Decide first what will be stored. Samples and reagents suit 2–8 °C undercounter or benchtop units, red cell units need 2–6 °C upright cabinets with chart recorder and independent alarm, and plasma needs a freezer or a combined cabinet. Compare temperature uniformity (2 K or better for units), recording method, battery duration and alarm contacts. If several cabinets are operated, choose remote monitoring with audit trail. Match capacity to peak stock and allow for growth. Check that the ambient range and power supply suit your laboratory, and ask for mapping data from the manufacturer.
Full specifications
| Temperature range | 2–6 °C, set point 4 °C |
|---|---|
| Net volume | 300–1000 L |
| Temperature uniformity | ≤ 2 K |
| Connectivity | Ethernet, Wi-Fi, RS-485 or GSM |
| Notification | SMS, email, relay output |
| Data logging interval | 1–10 min, adjustable |
| User access | Role-based, with audit trail |
| Alarm probe | Independent, glycol-buffered |
| Battery backup | Controller and communication module, ≥ 12 h |
| Power supply | 220–240 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Multi-cabinet blood banks
- Unattended overnight storage
- Regional transfusion centres
- Inspection and audit readiness
Key features
- Networked temperature, door and alarm data through Ethernet, Wi-Fi or GSM
- Central dashboard consolidates several cabinets with audit trail
- Escalation by SMS or email when temperature leaves the 2–6 °C band
- Local display and audible alarm continue working if the network fails
- Time-stamped data exportable for inspection and quality review
Frequently asked questions about Blood Bank Refrigerator with Remote Temperature Monitoring
The cabinet keeps controlling temperature and sounding its local alarm, and most loggers store data internally until the network returns. Alarm notifications to remote staff are lost during the outage, so a second route, such as GSM, is sometimes specified.
No. It adds a layer that needs its own validation, covering alarm delivery, time synchronisation, user access and data integrity. The refrigerator still requires temperature mapping, calibration and alarm challenge testing under the facility's quality system.
Yes. Most monitoring software handles probes from refrigerators, plasma freezers, incubators and rooms through one interface, with separate limits for each. Confirm the number of channels, sensor types and licence terms when specifying the system.
It is a temperature-controlled cabinet for blood samples, transfusion reagents or red cell units, with tight control, independent alarms and records. Laboratory versions range from undercounter sample refrigerators to upright cabinets for blood units.
Red cell components are stored at 2–6 °C, and samples and reagents are usually held at 2–8 °C. Follow the range set by your national blood transfusion service, because details differ between jurisdictions and products.
A blood bank unit has a narrower 2–6 °C range, better uniformity, a continuous recorder and an independent alarm with battery backup. Pharmacy units usually target 2–8 °C and may have simpler monitoring, so they are not interchangeable for blood units.