Graphite Furnace Atomic Absorption Spectrometer
石墨炉原子吸收光谱仪
- SKU ATS-0002
- Atomic Spectroscopy
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 185–900 nm |
|---|---|
| Atomizer | graphite tube, up to 3000 °C |
| Sample volume | 5–50 µL |
| Detection limit | 0.01–1 µg/L typical |
| Background correction | Zeeman or deuterium |
| Heating rate | up to 2000 °C/s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities
What is the Graphite Furnace Atomic Absorption Spectrometer?
A graphite furnace atomic absorption spectrometer atomizes microlitre samples electrothermally inside a graphite tube. It is chosen for trace and ultratrace elements at microgram per litre levels when only a small sample is available.
What is the Graphite Furnace Atomic Absorption Spectrometer?
A graphite furnace atomic absorption spectrometer atomizes microlitre samples electrothermally inside a graphite tube. It is chosen for trace and ultratrace elements at microgram per litre levels when only a small sample is available.
Overview
In this variant a small aliquot, typically 10 to 50 microlitres, is injected into a graphite tube that is heated in programmed stages: drying, pyrolysis to remove matrix, atomization and cleaning. The transient atom cloud absorbs the hollow-cathode lamp line, producing a peak whose area is proportional to mass. Because atomization is efficient and the residence time is long, detection limits are far lower than flame AAS, often in the nanogram per litre range for cadmium and lead. Zeeman or deuterium background correction is essential because pyrolysis leaves residual matrix. Matrix modifiers such as palladium and magnesium nitrate stabilize analytes and volatilize interferences. Graphite tubes and platforms are consumables with limited firings, and method development usually involves optimizing temperature programs for each matrix.
How does it work?
In atomic spectroscopy a sample is converted into free atoms in a flame, graphite furnace, plasma or hydride generation cell. The atoms absorb or emit light at wavelengths characteristic of each element. Atomic absorption passes a hollow-cathode lamp emission line through the atom cloud and measures the decrease in intensity according to the Beer-Lambert law. Atomic emission excites atoms in a plasma or flame and measures the light they emit as they relax. Atomic fluorescence excites atoms with a source and measures emitted light at a right angle, giving high sensitivity for hydride-forming elements. Inductively coupled plasma sources reach 6000 to 10000 K, atomizing and ionizing most elements; the resulting ions can be counted by mass spectrometry for very low detection limits. Calibration uses series of standards, internal standards, and background and matrix correction.
What are the key features?
- Transverse or longitudinal heated graphite tube atomizer
- Zeeman or deuterium background correction
- Programmable drying, pyrolysis, atomization and cleaning stages
- Automatic matrix modifier addition
- Autosampler with dilution and standard addition
- Graphite tube and platform consumable monitoring
What are the technical specifications?
A typical graphite furnace atomic absorption spectrometer configuration offers wavelength range of 185–900 nm, atomizer of graphite tube, up to 3000 °C, sample volume of 5–50 µL, detection limit of 0.01–1 µg/L typical, background correction of Zeeman or deuterium and heating rate of up to 2000 °C/s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Graphite Furnace Atomic Absorption Spectrometer is used in ultratrace metals in drinking water, lead and cadmium in food and blood, elemental impurities in pharmaceutical excipients and environmental soil and sediment digests. Across the wider Atomic Spectroscopy class, laboratories also deploy it for elemental impurity testing of pharmaceutical materials, trace metals in drinking water, wastewater and soil and food safety and nutritional element analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities, ISO 11885 Water quality — ICP-OES determination of elements, ISO 17294-2 Water quality — ICP-MS determination of elements, US EPA Method 200.7, US EPA Method 200.8, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Atomic spectroscopy installations need gas supplies, extraction and, for plasma systems, argon of high purity and substantial electrical power. Acetylene and nitrous oxide require proper regulators, flashback arrestors and ventilation. Sample preparation by acid digestion is a major source of error and contamination, so ultrapure acids and clean vessels are essential. Hollow-cathode lamps have limited life and may need warm-up and alignment. Background correction, internal standards and matrix matching control interferences from easily ionized elements, molecular species and viscosity. Verify performance daily with calibration standards and check stability with a continuing calibration verification. Maintain service records and monitor lamp, torch and graphite tube usage.
How do I select the right Graphite Furnace Atomic Absorption Spectrometer?
Select a graphite furnace AAS when detection limits must be low for a limited number of elements and sample volumes are small. Specify the elements, required detection limits, matrices and the modifier chemistry you plan to use. Confirm the autosampler supports dilution and standard addition, and plan for graphite tube and platform consumption, which is the main operating cost.
How does it compare with other Atomic Spectroscopy variants?
Choose the atomic technique by element, concentration and matrix. Flame atomic absorption is simple, robust and suited to milligram per litre levels in routine water, soil and metal samples. Graphite furnace atomic absorption reaches microgram per litre and below for a limited number of elements with small sample volumes. Inductively coupled plasma optical emission handles multi-element analysis at microgram per litre to percent levels with wide linear range. Inductively coupled plasma mass spectrometry reaches nanogram per litre and below for most elements and can measure isotopes. Atomic fluorescence is efficient for mercury, arsenic, selenium and antimony after hydride generation. Microwave plasma emission is an alternative to flame for some elements using nitrogen instead of acetylene. Confirm required detection limits, sample throughput, number of elements and available gases before selecting.
Full specifications
| Wavelength range | 185–900 nm |
|---|---|
| Atomizer | graphite tube, up to 3000 °C |
| Sample volume | 5–50 µL |
| Detection limit | 0.01–1 µg/L typical |
| Background correction | Zeeman or deuterium |
| Heating rate | up to 2000 °C/s |
| Temperature program steps | up to 20 |
| Autosampler positions | 60–120 vials |
| Graphite tube life | 200–2000 firings |
| Interface | USB / RS-232 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Ultratrace metals in drinking water
- Lead and cadmium in food and blood
- Elemental impurities in pharmaceutical excipients
- Environmental soil and sediment digests
Key features
- Transverse or longitudinal heated graphite tube atomizer
- Zeeman or deuterium background correction
- Programmable drying, pyrolysis, atomization and cleaning stages
- Automatic matrix modifier addition
- Autosampler with dilution and standard addition
- Graphite tube and platform consumable monitoring
Frequently asked questions about Graphite Furnace Atomic Absorption Spectrometer
Matrix modifiers such as palladium nitrate and magnesium nitrate stabilize the analyte so higher pyrolysis temperatures can remove matrix without losing the analyte. Phosphate modifiers reduce interference in cadmium and lead methods. Choosing the right modifier and pyrolysis temperature is central to method development and to controlling background.
Tube life depends on the atomization temperature, total number of firings, matrix acidity and the presence of halogen or alkaline salts. Typical service is 200 to 2000 firings, and sensitivity drift indicates a tube near the end of life. Keeping records of firings and sensitivity helps schedule replacement before results degrade.
For elements such as cadmium and lead, detection limits are often 0.01 to 0.1 microgram per litre using 20 microlitre injections, and can be lower with larger volumes or preconcentration. Far lower limits for many elements are possible with ICP-MS, so select between them based on the required limit and the element list.
Choose flame AAS for a few elements at milligram per litre levels with simple, low-cost operation. Choose graphite furnace AAS for microgram per litre trace levels with small samples. Choose ICP-OES for simultaneous multi-element work from microgram per litre to percent. Choose ICP-MS when the lowest detection limits or isotope ratios are required, accepting higher cost and matrix sensitivity.
Atomization produces smoke, molecular species and scattering that absorb or emit light unrelated to the analyte, which biases results if uncorrected. Deuterium, Zeeman or Smith-Hieftje correction subtracts these contributions. Matrix modifiers and standard addition further reduce structured background, particularly in graphite furnace analyses of complex samples.
Most samples need digestion or extraction to release the analytes and reduce matrix effects. Acid digestion in a closed vessel or microwave system is common, followed by dilution to a suitable acid concentration. Clean vessels, ultrapure reagents and method blanks control contamination. Solid samples measured by graphite furnace may need only suspension or slurry preparation in some methods.
Related models