Graphite Furnace Atomic Absorption Spectrometer

石墨炉原子吸收光谱仪

  • SKU ATS-0002
  • Atomic Spectroscopy
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range185–900 nm
Atomizergraphite tube, up to 3000 °C
Sample volume5–50 µL
Detection limit0.01–1 µg/L typical
Background correctionZeeman or deuterium
Heating rateup to 2000 °C/s
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities

What is the Graphite Furnace Atomic Absorption Spectrometer?

A graphite furnace atomic absorption spectrometer atomizes microlitre samples electrothermally inside a graphite tube. It is chosen for trace and ultratrace elements at microgram per litre levels when only a small sample is available.

What is the Graphite Furnace Atomic Absorption Spectrometer?

A graphite furnace atomic absorption spectrometer atomizes microlitre samples electrothermally inside a graphite tube. It is chosen for trace and ultratrace elements at microgram per litre levels when only a small sample is available.

Overview

In this variant a small aliquot, typically 10 to 50 microlitres, is injected into a graphite tube that is heated in programmed stages: drying, pyrolysis to remove matrix, atomization and cleaning. The transient atom cloud absorbs the hollow-cathode lamp line, producing a peak whose area is proportional to mass. Because atomization is efficient and the residence time is long, detection limits are far lower than flame AAS, often in the nanogram per litre range for cadmium and lead. Zeeman or deuterium background correction is essential because pyrolysis leaves residual matrix. Matrix modifiers such as palladium and magnesium nitrate stabilize analytes and volatilize interferences. Graphite tubes and platforms are consumables with limited firings, and method development usually involves optimizing temperature programs for each matrix.

How does it work?

In atomic spectroscopy a sample is converted into free atoms in a flame, graphite furnace, plasma or hydride generation cell. The atoms absorb or emit light at wavelengths characteristic of each element. Atomic absorption passes a hollow-cathode lamp emission line through the atom cloud and measures the decrease in intensity according to the Beer-Lambert law. Atomic emission excites atoms in a plasma or flame and measures the light they emit as they relax. Atomic fluorescence excites atoms with a source and measures emitted light at a right angle, giving high sensitivity for hydride-forming elements. Inductively coupled plasma sources reach 6000 to 10000 K, atomizing and ionizing most elements; the resulting ions can be counted by mass spectrometry for very low detection limits. Calibration uses series of standards, internal standards, and background and matrix correction.

What are the key features?

  • Transverse or longitudinal heated graphite tube atomizer
  • Zeeman or deuterium background correction
  • Programmable drying, pyrolysis, atomization and cleaning stages
  • Automatic matrix modifier addition
  • Autosampler with dilution and standard addition
  • Graphite tube and platform consumable monitoring

What are the technical specifications?

A typical graphite furnace atomic absorption spectrometer configuration offers wavelength range of 185–900 nm, atomizer of graphite tube, up to 3000 °C, sample volume of 5–50 µL, detection limit of 0.01–1 µg/L typical, background correction of Zeeman or deuterium and heating rate of up to 2000 °C/s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Graphite Furnace Atomic Absorption Spectrometer is used in ultratrace metals in drinking water, lead and cadmium in food and blood, elemental impurities in pharmaceutical excipients and environmental soil and sediment digests. Across the wider Atomic Spectroscopy class, laboratories also deploy it for elemental impurity testing of pharmaceutical materials, trace metals in drinking water, wastewater and soil and food safety and nutritional element analysis.

Which standards and certifications apply?

Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities, ISO 11885 Water quality — ICP-OES determination of elements, ISO 17294-2 Water quality — ICP-MS determination of elements, US EPA Method 200.7, US EPA Method 200.8, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Atomic spectroscopy installations need gas supplies, extraction and, for plasma systems, argon of high purity and substantial electrical power. Acetylene and nitrous oxide require proper regulators, flashback arrestors and ventilation. Sample preparation by acid digestion is a major source of error and contamination, so ultrapure acids and clean vessels are essential. Hollow-cathode lamps have limited life and may need warm-up and alignment. Background correction, internal standards and matrix matching control interferences from easily ionized elements, molecular species and viscosity. Verify performance daily with calibration standards and check stability with a continuing calibration verification. Maintain service records and monitor lamp, torch and graphite tube usage.

How do I select the right Graphite Furnace Atomic Absorption Spectrometer?

Select a graphite furnace AAS when detection limits must be low for a limited number of elements and sample volumes are small. Specify the elements, required detection limits, matrices and the modifier chemistry you plan to use. Confirm the autosampler supports dilution and standard addition, and plan for graphite tube and platform consumption, which is the main operating cost.

How does it compare with other Atomic Spectroscopy variants?

Choose the atomic technique by element, concentration and matrix. Flame atomic absorption is simple, robust and suited to milligram per litre levels in routine water, soil and metal samples. Graphite furnace atomic absorption reaches microgram per litre and below for a limited number of elements with small sample volumes. Inductively coupled plasma optical emission handles multi-element analysis at microgram per litre to percent levels with wide linear range. Inductively coupled plasma mass spectrometry reaches nanogram per litre and below for most elements and can measure isotopes. Atomic fluorescence is efficient for mercury, arsenic, selenium and antimony after hydride generation. Microwave plasma emission is an alternative to flame for some elements using nitrogen instead of acetylene. Confirm required detection limits, sample throughput, number of elements and available gases before selecting.

Full specifications

Full specifications
Wavelength range185–900 nm
Atomizergraphite tube, up to 3000 °C
Sample volume5–50 µL
Detection limit0.01–1 µg/L typical
Background correctionZeeman or deuterium
Heating rateup to 2000 °C/s
Temperature program stepsup to 20
Autosampler positions60–120 vials
Graphite tube life200–2000 firings
InterfaceUSB / RS-232

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Ultratrace metals in drinking water
  • Lead and cadmium in food and blood
  • Elemental impurities in pharmaceutical excipients
  • Environmental soil and sediment digests

Key features

  • Transverse or longitudinal heated graphite tube atomizer
  • Zeeman or deuterium background correction
  • Programmable drying, pyrolysis, atomization and cleaning stages
  • Automatic matrix modifier addition
  • Autosampler with dilution and standard addition
  • Graphite tube and platform consumable monitoring

Frequently asked questions about Graphite Furnace Atomic Absorption Spectrometer

Matrix modifiers such as palladium nitrate and magnesium nitrate stabilize the analyte so higher pyrolysis temperatures can remove matrix without losing the analyte. Phosphate modifiers reduce interference in cadmium and lead methods. Choosing the right modifier and pyrolysis temperature is central to method development and to controlling background.