Rotary Sample Divider
旋转分样器
- SKU ASP-0003
- Agricultural Sample Preparation
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Dividing principle | Rotary funnel or riffle chutes |
|---|---|
| Feed size | Up to 20 mm |
| Sample volume | 0.5–50 L per batch |
| Number of outlets | 4–16 containers |
| Splitting ratio | Equal portions, container dependent |
| Feed rate | Adjustable vibration |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 6498 (feed sample preparation), ISO 11464 (soil pretreatment), ISO 24333 (cereals sampling)
What is the Rotary Sample Divider?
A device that splits flowing or falling material into statistically identical subsamples. It is the right choice for reducing bulk grain, feed, seed and fertilizer samples without segregation bias before laboratory analysis.
What is the Rotary Sample Divider?
A device that splits flowing or falling material into statistically identical subsamples. It is the right choice for reducing bulk grain, feed, seed and fertilizer samples without segregation bias before laboratory analysis.
Overview
The rotary sample divider feeds material through a vibrating chute or hopper onto a rotating funnel that directs the stream into a ring of collection containers in turn. Because each container receives many short increments from the whole stream, the composition of every subsample matches the bulk, even when particles differ in size, shape or density. Riffle dividers achieve a similar result by passing material through a series of alternating chutes, while rotating models handle larger volumes and reduce operator effort. Dividing is essential before grinding and analysis, because a scoop from an un-divided sample can easily misrepresent grain, blended feed or fertilizer. Divider passages must be wide enough for the largest particles to avoid blockage and bias, and the equipment is cleaned between samples. Splitting ratios are selected so the final analytical portion meets the method mass requirement.
How does it work?
Agricultural samples must be reduced to a uniform, representative state before analysis. Grinding uses cutting blades, hammer mills, rotating knives or bead beating with a cryogenic or ambient medium, breaking cell walls and reducing particle size so that extraction is complete and reproducible. For fibrous forage and feed, a hammer mill with a screen controls the final particle size. Rotary and riffle dividers split a flowing or falling stream of material into equal portions, so a subsample reflects the bulk composition even when particles differ in size or density. Sieve shakers classify particles by size with vibratory, tapping or air-jet action, and the retained fractions can be weighed to check grind quality. Blenders and homogenisers mix and disintegrate fresh tissue or slurries for residue and enzyme work. Moisture loss, heat generation and contamination are the main risks to control.
What are the key features?
- Rotating funnel distributes increments evenly among containers.
- Produces subsamples statistically identical to the bulk.
- Handles large volumes with minimum operator effort.
- Passage widths accept the largest particles in the lot.
- Multiple container options set the splitting ratio.
- Cleaning between samples prevents carry-over.
What are the technical specifications?
A typical rotary sample divider configuration offers dividing principle of Rotary funnel or riffle chutes, feed size of Up to 20 mm, sample volume of 0.5–50 L per batch, number of outlets of 4–16 containers, splitting ratio of Equal portions, container dependent and feed rate of Adjustable vibration. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Rotary Sample Divider is used in grain and oilseed sample reduction, feed and fertilizer subsampling, seed lot sample division and traceability sample retention. Across the wider Agricultural Sample Preparation class, laboratories also deploy it for plant tissue nutrient analysis, feed and forage composition testing and pesticide residue sample preparation.
Which standards and certifications apply?
Relevant standards and methods include ISO 6498 (feed sample preparation), ISO 11464 (soil pretreatment), ISO 24333 (cereals sampling), ISO 6644 (cereals automatic sampling) and EN 14780 (solid biofuels). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Clean equipment thoroughly between samples with brushes and, where needed, solvent or dilute acid, and run blank grinds to detect carry-over of previous samples. Keep grinding brief or cooled to avoid heat that degrades proteins, sugars and volatile compounds, and weigh samples quickly to limit moisture change. For trace analysis, control contamination from blades, sieves and containers, and use appropriate reference materials. Verify grind quality by sieving a subsample and checking that the specified fraction meets the method requirement, and retain a portion of the prepared sample for repeat analysis. Log sample identity, preparation method, particle size and operator, and store prepared samples in sealed containers at the temperature the method requires.
How do I select the right Rotary Sample Divider?
Select the divider when a bulk sample must be reduced without segregation bias before grinding or analysis. Batch cone-and-quarter methods are acceptable for small lots but are slow and operator dependent. In an RFQ, specify feed size, sample volume, number of outlets and the required subsample mass.
How does it compare with other Agricultural Sample Preparation variants?
Begin with the analytical method, because it fixes the required particle size, sample mass and freedom from contamination. For trace element work, choose grinding surfaces that do not release the elements of interest, such as agate, zirconia or PTFE, and avoid stainless steel when chromium or nickel is measured. For fresh plant tissue and residue analysis, a cryogenic or high-speed homogeniser preserves labile compounds. For fibrous forage and feed, select a hammer mill with the screen size specified by the reference method, and add a divider so that the ground material can be reduced without segregation. Use a sieve shaker to verify grind quality and to prepare defined size fractions. Consider throughput, cleaning between samples, dust control and the risk of moisture change, and confirm that the equipment can meet the standard sample preparation procedure for the analysis planned.
Full specifications
| Dividing principle | Rotary funnel or riffle chutes |
|---|---|
| Feed size | Up to 20 mm |
| Sample volume | 0.5–50 L per batch |
| Number of outlets | 4–16 containers |
| Splitting ratio | Equal portions, container dependent |
| Feed rate | Adjustable vibration |
| Repeatability | RSD ≤ 2% between subsamples |
| Materials | Stainless steel or plastic |
| Throughput | 10–200 kg/h |
| Power supply | 220 VAC, 50 Hz |
| Operating temperature | 5–40 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Grain and oilseed sample reduction
- Feed and fertilizer subsampling
- Seed lot sample division
- Traceability sample retention
Key features
- Rotating funnel distributes increments evenly among containers.
- Produces subsamples statistically identical to the bulk.
- Handles large volumes with minimum operator effort.
- Passage widths accept the largest particles in the lot.
- Multiple container options set the splitting ratio.
- Cleaning between samples prevents carry-over.
Frequently asked questions about Rotary Sample Divider
Scooping from a pile takes material from one place, so larger or denser particles are over- or under-represented. A divider takes many increments from the whole stream, making the subsample composition match the bulk more closely.
Keep the analytical portion required by the method, plus a retained sample of the same or larger size for repeat or referee analysis. Both should be sealed, labelled and stored under conditions that prevent moisture change.
Sticky or high-moisture materials can bridge and block, which biases the split, so they are usually dried before dividing. Wide passages, gentle vibration and short feed bursts reduce blockage for difficult samples.
Extraction efficiency depends on surface area, so coarse or variable particle size gives incomplete and biased results. Reference methods specify a sieve or screen size, and grinding to that size makes nutrient, residue and fibre results reproducible between laboratories.
Match the grinding material to the analysis: agate, zirconia or PTFE for trace elements and stainless steel or carbide for routine work. Pre-clean with a blank sample, avoid painted or plated surfaces and store ground material in inert containers.
Grinding can segregate particles by size and density, and a scoop taken without dividing may not represent the lot. Rotary or riffle dividers pass the material through moving channels so each fraction is statistically identical to the bulk.