Programmable Incubator
可编程培养箱
- SKU STI-0004
- Standard Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–300 L |
|---|---|
| Temperature range | RT+5 to 80 C |
| Programs | 10–30 |
| Segments per program | Up to 30 |
| Ramp rate | 0.1–5 C/min |
| Temperature uniformity | ±0.5–1 C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880
What is the Programmable Incubator?
A programmable incubator follows stored multi-step temperature and time profiles, so incubation cycles can be repeated exactly. It is chosen for methods that use ramps, staged holds or documented temperature histories in regulated or development laboratories.
What is the Programmable Incubator?
A programmable incubator follows stored multi-step temperature and time profiles, so incubation cycles can be repeated exactly. It is chosen for methods that use ramps, staged holds or documented temperature histories in regulated or development laboratories.
Overview
This incubator adds a multi-segment controller to the standard chamber, storing 10 to 30 programs with ramp, hold and cool steps, each with its own setpoint and duration. Methods that raise temperature gradually, hold at several stages or cycle between temperatures can run unattended. Data logging records setpoint and actual temperature with timestamps through RS-485, USB or Ethernet for validation and traceability, and real-time and historical curves appear on the display. Chambers run 50 to 300 liters with uniformity of plus or minus 0.5 to 1 C, reaching 70 to 80 C. Some models coordinate with cooling or add profiles for enzyme and biochemical methods. It suits regulated microbiology, stability-style studies and research requiring reproducible temperature histories.
How does it work?
A standard incubator holds temperature with heating elements or a water jacket around an insulated chamber. A Pt100 or thermistor sensor feeds a PID controller that switches the elements, and air circulates either naturally by convection or with a fan for tighter uniformity. Natural convection gives gentle conditions with little evaporation and no fan to disturb cultures, while forced air gives better uniformity and faster recovery after door openings. Shear layers of insulation and a gasketed door limit heat loss. Units work above ambient, typically 5 to 80 C, so no refrigeration is needed. Controls range from mechanical thermostats to digital PID units with timers, alarms and data output. Shelves or trays position the samples, and an inner glass door on some models lets operators view cultures without disturbing the chamber.
What are the key features?
- Multi-segment controller with 10 to 30 programs
- Programmable ramp, hold and cool steps
- Data logging with RS-485, USB or Ethernet
- Real-time and historical curve display
- Uniformity of ±0.5 to 1 C
- Timestamps for validation and traceability
What are the technical specifications?
A typical programmable incubator configuration offers chamber volume of 50–300 L, temperature range of RT+5 to 80 C, programs of 10–30, segments per program of Up to 30, ramp rate of 0.1–5 C/min and temperature uniformity of ±0.5–1 C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Programmable Incubator is used in regulated incubation methods, staged enzyme and biochemical assays, microbial growth studies, stability-style conditioning and method transfer and validation. Across the wider Standard Incubators class, laboratories also deploy it for bacterial and fungal culture, enzyme and biochemical assays and food and beverage microbiological testing.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 4833-1, ISO 6222 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the incubator on a level bench away from sunlight, heat sources, doors and drafts, in a room with stable ambient temperature below about 30 C, and leave clearance for ventilation. Load shelves evenly and leave gaps so air can circulate. Do not overload, since dense loads slow recovery and widen gradients. Clean the chamber between batches with a mild disinfectant compatible with the interior, and avoid corrosive agents on stainless steel. Check the door gasket for wear and the sensor for drift at defined intervals, calibrating with a reference probe across the chamber. Keep temperature and maintenance records, especially when the incubator supports regulated work.
How do I select the right Programmable Incubator?
Select the programmable incubator when the method defines ramp rates, multiple holds or a temperature history that must be documented. Single-setpoint incubators are cheaper for constant-temperature culture. In the RFQ, specify programs and segments, ramp range, data interface, record format and alarm functions.
How does it compare with other Standard Incubators variants?
Choose a standard incubator when the setpoint is above ambient and neither CO2 control nor refrigeration is needed. Set the temperature range with margin above the highest working temperature and confirm uniformity at that point, often plus or minus 0.5 to 2 C. Decide between natural and forced convection: natural suits microbiology and low-evaporation work, forced suits high-throughput and fast recovery. Match chamber volume to vessel count and shelf area. Consider the controller, choosing digital for reproducibility or programmable for stepped profiles, and check alarms, data output and door type. Confirm power, bench or floor placement and service access before ordering.
Full specifications
| Chamber volume | 50–300 L |
|---|---|
| Temperature range | RT+5 to 80 C |
| Programs | 10–30 |
| Segments per program | Up to 30 |
| Ramp rate | 0.1–5 C/min |
| Temperature uniformity | ±0.5–1 C |
| Data interface | RS-485, USB or Ethernet |
| Alarms | Deviation and over-temperature |
| Heating power | 500 W–1.5 kW |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Regulated incubation methods
- Staged enzyme and biochemical assays
- Microbial growth studies
- Stability-style conditioning
- Method transfer and validation
Key features
- Multi-segment controller with 10 to 30 programs
- Programmable ramp, hold and cool steps
- Data logging with RS-485, USB or Ethernet
- Real-time and historical curve display
- Uniformity of ±0.5 to 1 C
- Timestamps for validation and traceability
Frequently asked questions about Programmable Incubator
It stores multi-step temperature profiles, so heating rates, hold times and cooling can be controlled and repeated automatically. It also logs setpoint and actual temperature with timestamps, supporting validation and traceability that a fixed-setpoint incubator cannot provide.
Yes. It records setpoint and actual temperature with timestamps and exports CSV or text through a serial, USB or network interface. Where data integrity rules apply, the logging system must itself be access-controlled and qualified.
Typical models store 10 to 30 programs with up to 30 segments each. Each segment holds a target temperature and duration, so several standard methods and development profiles can be kept available at once.
It holds a set temperature above ambient to culture bacteria and fungi, incubate enzyme and immunoassays, condition samples and support food and clinical microbiology. Standard incubators have no CO2 control or refrigeration, unlike cell-culture and cooling models.
Most hold ambient plus 5 C up to 60 to 80 C. Common setpoints are 30 to 37 C for microbiology and enzyme work, and 55 to 60 C for some assays. Because they only heat, they cannot serve setpoints below room temperature.
Natural convection is gentle, minimizes evaporation and has no fan to disturb cultures, which suits plates and sensitive samples. Forced convection gives tighter uniformity and faster recovery, better for dense loads and high-throughput work where temperature consistency matters more.