Variable-Speed Digital Tube Rotator
可调速数显试管旋转器
- SKU ROM-0002
- Rotary Mixers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Speed range | 5–100 rpm |
|---|---|
| Speed accuracy | ± 1–2 rpm |
| Display | LED or LCD |
| Timer range | 1 min–99 h or continuous |
| Direction | Clockwise, counter-clockwise, alternating |
| Tube capacity | 0.5–50 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, EN 61326-1
What is the Variable-Speed Digital Tube Rotator?
A variable-speed digital tube rotator offers adjustable speed, a timer and often reversible direction, displayed on a digital panel. It suits laboratories that run several protocols with different mixing needs, including delicate cell work and viscous samples.
What is the Variable-Speed Digital Tube Rotator?
A variable-speed digital tube rotator offers adjustable speed, a timer and often reversible direction, displayed on a digital panel. It suits laboratories that run several protocols with different mixing needs, including delicate cell work and viscous samples.
Overview
The variable-speed digital rotator adds electronic control to the basic design. A brushless DC motor is driven by a controller that sets speed in steps of 1 rpm across a range such as 5 to 100 rpm, and the actual speed is shown on an LED or LCD display. A timer allows runs from a few minutes to several hours, or continuous operation, and some units allow the direction to reverse at set intervals to improve mixing. Rotor designs vary from 12 to 24 positions, and holders accommodate tubes from 0.5 to 50 mL. The motor has overload protection and a soft start that prevents liquid from splashing. Speed accuracy is typically within 1 to 2 rpm. This design fits laboratories where reproducible protocols are required and operators need to record and repeat run conditions.
How does it work?
A rotary mixer has an electric motor, usually a brushless DC or gear motor, that drives a horizontal shaft carrying a rotor, disc or carousel. Tubes are clipped into holders around the circumference, and the rotor turns them through 360 degrees so that the air bubble inside travels from one end of the tube to the other. This repeated inversion moves liquid over the full tube length and mixes components by gravity-driven flow rather than by turbulence. Speeds are typically 5 to 100 rpm, which avoids foaming, cell damage and protein denaturation. Some models add a tilt, orbital or vibration motion to loosen pellets. Key components are the motor and gearbox, the rotor with tube holders, a speed controller, a timer and, on better units, an overload protection circuit. Holder design determines the compatible tube sizes from 0.5 mL to 50 mL and bottles.
What are the key features?
- Speed adjustable in 1 rpm steps across about 5–100 rpm
- Digital display of set and actual speed and run time
- Timer from 1 minute to several hours or continuous run
- Reversible direction at programmed intervals for thorough mixing
- Soft start to prevent splashing and sample loss
- Overload and stall protection for motor and gearbox
What are the technical specifications?
A typical variable-speed digital tube rotator configuration offers speed range of 5–100 rpm, speed accuracy of ± 1–2 rpm, display of LED or LCD, timer range of 1 min–99 h or continuous, direction of Clockwise, counter-clockwise, alternating and tube capacity of 0.5–50 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Variable-Speed Digital Tube Rotator is used in cell suspension handling, protein and antibody incubation, viscous sample mixing and protocol-driven sample preparation. Across the wider Rotary Mixers class, laboratories also deploy it for blood and plasma sample mixing, cell suspension handling and protein and antibody incubation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-051, EN 61326-1, GB 4793.1 and CLSI GP41. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the rotary mixer on a level, stable surface and keep the rotor balanced by loading tubes symmetrically, which reduces vibration and bearing wear. Use tube holders that match the tube diameter and confirm caps are tight, since leaks can damage the motor. If the unit will run in an incubator or cold room, choose a model rated for the temperature and humidity range. Clean the rotor with a mild disinfectant, and disconnect power before cleaning. Inspect holders and clips regularly for cracks. Verify speed periodically with a tachometer, and keep records if the instrument supports a quality system. Electrical safety should follow IEC 61010-1, and the supplier should document the maximum load and duty cycle.
How do I select the right Variable-Speed Digital Tube Rotator?
Choose the digital variable-speed model when protocols require repeatable speed and time or when you handle both delicate and viscous samples on the same instrument. A fixed-speed unit is cheaper but less flexible. In the RFQ, specify speed range, timer, reversing needs, tube sizes and whether the unit must run in a cold room.
How does it compare with other Rotary Mixers variants?
The decisive parameters are tube format, speed range, control features and load capacity. First define the tubes or bottles to be mixed, from 0.5 mL microtubes to 50 mL conical tubes or blood collection tubes, and choose a rotor with matching holders. Next, decide whether fixed speed is sufficient or whether adjustable speed, a timer and reversible direction are needed for protocol control. Check the maximum load and number of positions, because overloaded rotors run unevenly and wear the gearbox. Consider additional motions such as orbital, tilt or vibration if pellets must be resuspended. For cell work or biological samples, confirm that the unit is small enough to fit inside an incubator or cold room and is rated for humidity. Review noise, cleanability of the rotor and availability of replacement holders in the RFQ.
Full specifications
| Speed range | 5–100 rpm |
|---|---|
| Speed accuracy | ± 1–2 rpm |
| Display | LED or LCD |
| Timer range | 1 min–99 h or continuous |
| Direction | Clockwise, counter-clockwise, alternating |
| Tube capacity | 0.5–50 mL |
| Number of positions | 12–24 tubes |
| Motor type | Brushless DC |
| Maximum load | 2 kg |
| Power supply | 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 240 × 260 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell suspension handling
- Protein and antibody incubation
- Viscous sample mixing
- Protocol-driven sample preparation
Key features
- Speed adjustable in 1 rpm steps across about 5–100 rpm
- Digital display of set and actual speed and run time
- Timer from 1 minute to several hours or continuous run
- Reversible direction at programmed intervals for thorough mixing
- Soft start to prevent splashing and sample loss
- Overload and stall protection for motor and gearbox
Frequently asked questions about Variable-Speed Digital Tube Rotator
A soft start ramps the motor up gradually, so liquid does not splash against the cap and cells or proteins are not exposed to sudden shear. It also reduces mechanical stress on the gearbox and tube holders.
Periodic reversal changes the path of the air bubble and helps mix samples that would otherwise settle along one side of the tube. It is useful for viscous liquids, beads and cell suspensions.
Displayed speed on a digital rotator is typically accurate to within 1 to 2 rpm at no load. Verify with an optical tachometer during installation and recalibrate if the motor is replaced or if results drift.
A rotary mixer turns tubes or vials end-over-end on a rotating rotor at low speed. It mixes liquids gently without foaming or shear, and is used for blood, cells, proteins, extractions and reagents in clinical and research laboratories.
A rotary mixer inverts tubes slowly through 360 degrees and mixes by gravity flow, while a vortex mixer shakes tubes in a fast orbit. Rotary mixing suits fragile samples and long incubations, whereas vortexing is better for quick, vigorous mixing.
Most protocols use 10 to 40 rpm. Lower speeds of 5 to 15 rpm are used for fragile cells, while higher speeds of 40 to 100 rpm are used for viscous liquids. Follow the assay or tube manufacturer's instructions.