Floor Platform Balance
落地台秤
- SKU PLB-0002
- Platform Balances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- OIML R 76 type approval (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Capacity | 150 kg–3,000 kg |
|---|---|
| Readability | 10 g–500 g |
| Platform size | 600 × 600 to 1,000 × 1,200 mm |
| Platform height | ≈ 60–100 mm |
| Number of load cells | 4 |
| Ingress protection | IP65–IP68 (option dependent) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: OIML R 76-1, OIML R 60, EN 45501
What is the Floor Platform Balance?
A floor platform balance has a large low platform, typically 600 by 600 mm to 1,000 by 1,200 mm, with capacities from 150 kg to 3 tonnes. It weighs drums, barrels and pallets that can be rolled or lifted on, in laboratories, pilot plants and warehouses.
What is the Floor Platform Balance?
A floor platform balance has a large low platform, typically 600 by 600 mm to 1,000 by 1,200 mm, with capacities from 150 kg to 3 tonnes. It weighs drums, barrels and pallets that can be rolled or lifted on, in laboratories, pilot plants and warehouses.
Overview
Floor scales sit directly on the floor with a low profile of 60 to 100 mm, often with a ramp to allow pallet trucks. Four load cells support a steel or stainless platform, and readability is 10 g to 500 g for capacities from 150 kg to 3,000 kg. Platforms are checker-plated for grip, and stainless versions are available for washdown. An indicator on a column or wall shows weight, and functions include tare, hold, checkweighing and totalizing. Ingress protection of IP65 to IP68 depends on cell and junction box. Overload stops and corner adjustment protect accuracy. A mobile floor scale may be fitted with wheels and a handle to move between areas. They suit drum filling, incoming inspection and pallet weighing.
How does it work?
Platform balances use strain-gauge load cells. Each cell contains a metal spring element, such as aluminum or stainless steel, bonded with resistive strain gauges in a Wheatstone bridge. Load on the platform deforms the element, changing gauge resistance and producing a small voltage proportional to force. One to four cells support the platform, and a junction box sums their signals. The indicator amplifies and digitizes the signal, corrects for temperature and non-linearity, and displays mass. Overload stops protect the cells from shock, and a steel or stainless platform spreads the load. Calibration uses certified test weights, and corner-load adjustment compensates for off-center placement. Indicators may be attached by cable or wireless link and offer functions such as tare, counting, checkweighing and totalizing.
What are the key features?
- Low-profile checker-plate platform of 60 to 100 mm height
- Four load cells with IP65 to IP68 protection options
- Ramp option for pallet trucks and hand trolleys
- Column or wall-mounted indicator with tare and totalizing
- Stainless steel version for washdown and corrosive areas
What are the technical specifications?
A typical floor platform balance configuration offers capacity of 150 kg–3,000 kg, readability of 10 g–500 g, platform size of 600 × 600 to 1,000 × 1,200 mm, platform height of ≈ 60–100 mm, number of load cells of 4 and ingress protection of IP65–IP68 (option dependent). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Floor Platform Balance is used in drum and barrel weighing, pallet weighing, incoming goods inspection and drum filling and batching. Across the wider Platform Balances class, laboratories also deploy it for drum and container weighing, bulk material batching and incoming goods inspection.
Which standards and certifications apply?
Relevant standards and methods include OIML R 76-1, OIML R 60, EN 45501, IEC 60079-0, IEC 61010-1, GB/T 7724 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and OIML R 76 type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a flat, rigid floor or solid bench, and adjust feet until the platform sits evenly on every support. Avoid placing the scale where forklifts, vibrations or drafts disturb readings. Calibrate on site with certified test weights, ideally around 50 to 100 percent of capacity, and check corner loading. Protect cables from damage and moisture, and use junction boxes with appropriate ingress protection. Do not overload or drop heavy items on the platform, since shocks damage load cells. Inspect feet, cells and cables at regular intervals, and clean under the platform to prevent debris from blocking movement. For trade or regulated use, verification by the competent authority and sealing are required.
How do I select the right Floor Platform Balance?
Select a floor scale for loads above about 100 kg or pallets that cannot be lifted to a bench. A ramp is needed for trolleys. In the RFQ, specify capacity, division, platform size, ramp, material, IP rating and indicator type.
How does it compare with other Platform Balances variants?
Begin with the heaviest load including the container, then select a capacity about 20 to 30 percent above it, and pick a readability that gives at least 3,000 divisions for general use. Platform size should fit the largest vessel or pallet with margin. Choose material by environment: painted carbon steel for dry areas, stainless steel for wet or corrosive areas. Consider hazardous-area certification if flammable solvents are present, and ingress protection for washdown. Check the indicator functions such as checkweighing, counting and data output, and whether wireless or remote display is needed. For trade use, confirm legal-for-trade approval. Finally, confirm access, such as a ramp for floor models, and overload capacity for drum handling.
Full specifications
| Capacity | 150 kg–3,000 kg |
|---|---|
| Readability | 10 g–500 g |
| Platform size | 600 × 600 to 1,000 × 1,200 mm |
| Platform height | ≈ 60–100 mm |
| Number of load cells | 4 |
| Ingress protection | IP65–IP68 (option dependent) |
| Overload protection | 150% of capacity |
| Stabilization time | ≈ 2–3 s |
| Indicator | Column or wall mounted, LCD or LED |
| Interfaces | RS-232, RS-485 optional |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drum and barrel weighing
- Pallet weighing
- Incoming goods inspection
- Drum filling and batching
Key features
- Low-profile checker-plate platform of 60 to 100 mm height
- Four load cells with IP65 to IP68 protection options
- Ramp option for pallet trucks and hand trolleys
- Column or wall-mounted indicator with tare and totalizing
- Stainless steel version for washdown and corrosive areas
Frequently asked questions about Floor Platform Balance
Not usually. Low-profile models of 60 to 100 mm sit directly on the floor, and a ramp gives access. A pit gives flush installation for forklifts but requires civil work and drainage, so most laboratories use surface-mounted units.
Place the empty pallet or drum and tare the scale, then fill or place the drum at the platform center. Do not exceed capacity, and use a scale with a low profile or ramp so the drum can be rolled on safely.
Check against test weights at least quarterly or as defined by the quality system, and after any impact, move or repair. Legal-for-trade scales must be re-verified at intervals set by local metrology authorities, commonly annually.
A platform balance has a large platform and handles loads from several kilograms to tonnes with readability of 0.1 g to 1 kg, while a precision balance weighs up to a few kilograms at 1 mg to 0.01 g. Platform units use load cells and are built for robust use.
Add the heaviest load and its container, then choose a capacity 20 to 30 percent higher. Avoid excessive oversizing since resolution worsens. Verify the number of divisions, which should be about 3,000 or more for general use.
Corner load error is the difference in reading when the same mass is placed at different positions on the platform. It is adjusted at calibration, and good platforms keep it within a fraction of a division. Place loads near the center for best accuracy.
Related models