

Robotic Pipette Tip
机器人移液吸头
- SKU PIT-0005
- Pipette Tips
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Material | Polypropylene |
|---|---|
| Format | 8, 96 or 384 per rack |
| Tolerance | Tight dimensional control |
| Tip height control | Critical for pick-up |
| Filter | Optional |
| Surface | Standard or low retention |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8655 (piston-operated volumetric apparatus), ISO 13485 (medical device quality management), ISO 10993 (biological evaluation of medical devices)
What is the Robotic Pipette Tip?
A robotic pipette tip is designed for automated liquid handling platforms, with rack dimensions and fit tolerances that allow reliable pick-up. It is used in high-throughput workflows. Racks must match the platform exactly.
What is the Robotic Pipette Tip?
A robotic pipette tip is designed for automated liquid handling platforms, with rack dimensions and fit tolerances that allow reliable pick-up. It is used in high-throughput workflows. Racks must match the platform exactly.
Overview
The tip is moulded to tight dimensional tolerances and supplied in racks that match the platform's pick-up head, with tip height, spacing and alignment controlled so 8, 96 or 384 tips can be mounted at once. The tips are usually polypropylene, optionally with filters and low-retention surfaces, and are available sterile and nuclease-free. Because the robot cannot feel the fit, the tip-to-head seal depends entirely on moulding consistency, so tip height variation and rack flatness are critical. Substituting another supplier's rack can cause failed pick-ups, dropped tips or volume errors, so robotic tips should be specified by the platform supplier or a proven equivalent. They are consumed in large numbers, so cost, waste and refill options affect running budget, and lot changes should be verified.
How does it work?
A pipette tip works as the sample container and the seal in an air displacement system. The tip pushes onto the pipette shaft or cone, forming an airtight fit, so when the piston draws up an air column the liquid is pulled into the tip by the resulting pressure difference. The volume delivered depends on the seal, the tip geometry, the liquid properties and the technique, so tips are matched to the pipette model and tested with it under ISO 8655. Filter tips contain a hydrophobic barrier that stops aerosol and liquid from reaching the pipette shaft, protecting the instrument and reducing cross contamination between samples. Low-retention tips have a treated surface so less liquid stays on the wall. Wide-bore tips have a larger opening for viscous or fragile liquids, and robotic tips are held and positioned by automated platforms, with dimensional tolerances that allow reliable pick-up.
What are the key features?
- Tight dimensional tolerances
- Racks matching the platform head
- 8, 96 or 384 tips per rack
- Filter and low-retention options
- Sterile and nuclease-free grades
- Controlled tip height and spacing
What are the technical specifications?
A typical robotic pipette tip configuration offers material of Polypropylene, format of 8, 96 or 384 per rack, tolerance of Tight dimensional control, tip height control of Critical for pick-up, filter of Optional and surface of Standard or low retention. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Robotic Pipette Tip is used in high-throughput screening, automated PCR setup, robotic sample preparation and assay plate preparation. Across the wider Pipette Tips class, laboratories also deploy it for PCR and molecular biology, cell culture and microbiology and clinical sample handling.
Which standards and certifications apply?
Relevant standards and methods include ISO 8655 (piston-operated volumetric apparatus), ISO 13485 (medical device quality management), ISO 10993 (biological evaluation of medical devices), USP <88> (biological reactivity tests) and EN ISO 11607 (packaging for terminally sterilized devices). Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Verify tip fit and volume accuracy at the working volumes with your pipette, since tip manufacturing tolerances vary. Keep racks sealed until use if tips are sterile or certified nuclease-free, and do not touch the tip body, because skin oils and dust affect wetting and volumes. Change tips between samples to prevent carry-over, and use filter tips as an additional barrier rather than as a substitute for changing tips. Do not autoclave non-sterile tips unless the supplier states they are autoclavable, because heat can deform the cone and destroy the seal. Store tips away from heat, sunlight and solvent vapour, and check that tip height in the rack is uniform. Control static, which makes tips stick to each other and to powders, with an ioniser where needed.
How do I select the right Robotic Pipette Tip?
Use the tip and rack specified by the platform supplier, or a tested equivalent, and verify pick-up and volumes at installation. RFQ: platform model, head format, volumes, filter and validation needs. Provide platform model and head format.
How does it compare with other Pipette Tips variants?
Match the tip to the pipette model and volume first, since a poor fit causes leaks and volume errors. Choose filter tips when contamination control matters, for PCR, molecular and infectious work, and where the pipette shaft must stay clean. Choose low-retention tips for viscous, foaming, surfactant-containing or precious samples, especially at small volumes. Choose wide-bore tips for cell suspensions, genomic DNA and other viscous or shear-sensitive liquids that would clog or be damaged in a narrow tip. For automated platforms, use the tip specified by the instrument supplier, since rack dimensions, tip height and fit are critical. Confirm that tips are certified free of DNase, RNase, DNA and pyrogens where molecular or cell work requires it, and check sterility if needed. Finally, buy in a quality grade consistent with the method, and verify volume performance with your pipette.
Full specifications
| Material | Polypropylene |
|---|---|
| Format | 8, 96 or 384 per rack |
| Tolerance | Tight dimensional control |
| Tip height control | Critical for pick-up |
| Filter | Optional |
| Surface | Standard or low retention |
| Sterility | Optional |
| Nuclease | Optional free grade |
| Refill | Refill stack option |
| Use | Automated liquid handling |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-throughput screening
- Automated PCR setup
- Robotic sample preparation
- Assay plate preparation
Key features
- Tight dimensional tolerances
- Racks matching the platform head
- 8, 96 or 384 tips per rack
- Filter and low-retention options
- Sterile and nuclease-free grades
- Controlled tip height and spacing
Frequently asked questions about Robotic Pipette Tip
The platform picks tips by position and cannot feel the fit, so tip height, spacing and rack flatness must match exactly. A mismatched rack causes failed pick-ups, dropped tips or volume errors.
Yes. Verify accuracy and precision on the platform with the specified tips, since head alignment, tip fit and calibration all affect volumes. Repeat after tip or rack changes.
Many do, using refill stacks that reload a reusable rack, which cuts plastic waste and cost in high-throughput laboratories. Confirm refill compatibility with your platform racks.
The tip must push onto the shaft or cone with a slight resistance and form an airtight seal, and it should not wobble or fall off. Use tips recommended for the pipette model and verify volumes.
For PCR, molecular biology, infectious samples and any work where aerosol must not reach the pipette shaft. They protect the instrument and reduce cross contamination, but do not replace changing tips.
The treated surface reduces the film of liquid left on the tip wall, improving recovery and accuracy for viscous, surfactant-containing or expensive samples, especially at microlitre volumes.
Related models






