Explosion-Proof Upright Refrigerator for Hazardous Areas — product photo

Explosion-Proof Upright Refrigerator for Hazardous Areas

危险区域用立式防爆冷藏箱

  • SKU EPR-0003
  • Explosion-Proof Refrigerators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ATEX 2014/34/EU (to be confirmed)
  • IECEx (to be confirmed)
  • GB 3836 (Ex mark) (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range2–8 °C
Net volume300–1000 L
Protection typeEx db eb mb (model-dependent)
Gas groupIIB (IIC on request)
Temperature classT4 (≤ 135 °C)
Equipment protection levelGb (Zone 1)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60079-0, IEC 60079-1, IEC 60079-17

What is the Explosion-Proof Upright Refrigerator for Hazardous Areas?

An upright 2–8 °C refrigerator whose electrical parts are certified for explosive atmospheres, typically Zone 1 or Zone 2 gas Group IIB with T4 rating. It is chosen where flammable vapours may be present outside the cabinet as well as inside.

What is the Explosion-Proof Upright Refrigerator for Hazardous Areas?

An upright 2–8 °C refrigerator whose electrical parts are certified for explosive atmospheres, typically Zone 1 or Zone 2 gas Group IIB with T4 rating. It is chosen where flammable vapours may be present outside the cabinet as well as inside.

Overview

An explosion-proof refrigerator is built with flameproof (Ex d), increased safety (Ex e), pressurised or encapsulated (Ex m) protection for compressor, controller, lighting and any other electrical equipment, in accordance with IEC 60079 and, in China, GB 3836. A typical marking is Ex db eb mb IIB T4 Gb, meaning Zone 1 for IIB gases such as ethylene at a maximum surface temperature of 135 °C. Volume is 300–1000 L, and the evaporator is sealed or placed so that it does not create sparks. The cabinet has anti-static interior, cable glands and a grounding point. It is heavier and more expensive than a flammable-storage unit and must be installed, inspected and repaired under explosion-protection rules. The certificate and marking must match the site's area classification.

How does it work?

Standard refrigerators contain sparking components, such as thermostats, door switches, light bulbs and fan motors, that can ignite vapours from flammable liquids stored inside. Flammable-storage refrigerators relocate or seal these parts outside the storage compartment, preventing an internal ignition. Fully explosion-proof refrigerators go further, using flameproof, increased-safety or encapsulated protection for every electrical component according to IEC 60079 or GB 3836, so neither the interior nor the exterior can ignite a surrounding explosive atmosphere. The cooling process itself is conventional vapour compression, but the compressor, controller and wiring are built to certified standards. Labels show gas group, temperature class and protection level, which must match the site classification.

What are the key features?

  • Electrical equipment protected to IEC 60079 or GB 3836 for gas atmospheres
  • Typical marking Ex db eb mb IIB T4 Gb with surface temperature limit
  • Anti-static interior and grounding point
  • Sealed evaporator and certified cable glands
  • Volume of 300–1000 L at 2–8 °C

What are the technical specifications?

A typical explosion-proof upright refrigerator for hazardous areas configuration offers temperature range of 2–8 °C, net volume of 300–1000 L, protection type of Ex db eb mb (model-dependent), gas group of IIB (IIC on request), temperature class of T4 (≤ 135 °C) and equipment protection level of Gb (Zone 1). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Explosion-Proof Upright Refrigerator for Hazardous Areas is used in chemical plant laboratories, petrochemical sampling, solvent storage areas and pharmaceutical synthesis. Across the wider Explosion-Proof Refrigerators class, laboratories also deploy it for flammable solvent storage, hazardous area laboratories and reactive reagent cold storage.

Which standards and certifications apply?

Relevant standards and methods include IEC 60079-0, IEC 60079-1, IEC 60079-17, GB 3836.1, NFPA 45, NFPA 30, ATEX Directive 2014/34/EU and IEC 61010-2-011. Certification candidates for this model are CE, ISO 9001 manufacturing, ATEX 2014/34/EU, IECEx and GB 3836 (Ex mark); each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install on a level, load-bearing floor with ventilation clearance, and ground the cabinet as instructed. Keep containers sealed and labelled, use secondary containment, and respect quantity limits from fire codes. Do not add unapproved electrical devices inside. Inspect regularly and record findings, including gasket condition and alarm function. Certified units must be serviced by trained personnel using approved parts, and changes can invalidate the certification. Calibrate temperature displays at least annually, and plan for power-failure response because stored solvents and reagents may be temperature-sensitive.

How do I select the right Explosion-Proof Upright Refrigerator for Hazardous Areas?

Choose this variant for classified Zone 1 or Zone 2 areas and for bulk flammable storage where certification is required. Give your area classification, gas group, temperature class, volume and supply voltage in the RFQ. Request the certificate and test-laboratory report, and check that it covers the complete unit.

How does it compare with other Explosion-Proof Refrigerators variants?

Start with the hazard. If containers are sealed, quantities are small and the room is not a classified zone, a flammable-storage refrigerator may be adequate. If the area is classified Zone 1 or Zone 2, or large volumes are stored, specify a certified explosion-proof model with the right gas group and temperature class. Decide on capacity, upright or undercounter format, whether sub-zero storage is needed, and the alarm and signalling arrangement. Check the certificate against the area classification, confirm power supply and floor loading, and involve your safety officer. Never convert or modify a standard unit.

Full specifications

Full specifications
Temperature range2–8 °C
Net volume300–1000 L
Protection typeEx db eb mb (model-dependent)
Gas groupIIB (IIC on request)
Temperature classT4 (≤ 135 °C)
Equipment protection levelGb (Zone 1)
InteriorAnti-static, solvent-resistant
EarthingExternal grounding terminal
RefrigerantR290 or R134a
Power supply220–240 V, 50 Hz or 380 V three-phase

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Chemical plant laboratories
  • Petrochemical sampling
  • Solvent storage areas
  • Pharmaceutical synthesis

Key features

  • Electrical equipment protected to IEC 60079 or GB 3836 for gas atmospheres
  • Typical marking Ex db eb mb IIB T4 Gb with surface temperature limit
  • Anti-static interior and grounding point
  • Sealed evaporator and certified cable glands
  • Volume of 300–1000 L at 2–8 °C

Frequently asked questions about Explosion-Proof Upright Refrigerator for Hazardous Areas

It indicates a combination of protection methods, flameproof (db), increased safety (eb) and encapsulation (mb), for gas group IIB, with a maximum surface temperature of 135 °C (T4), at equipment protection level Gb for Zone 1 use.

Request a quotation for the Explosion-Proof Upright Refrigerator for Hazardous Areas

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.