Micro Air Quality Monitoring Station

微型空气质量监测站

  • SKU AAS-0003
  • Ambient Air Stations
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measured pollutantsSO2, NO2, O3, CO, PM10, PM2.5
PM measurementOptical scattering, 0–1000 µg/m³
Gas measurementElectrochemical sensors, ppb level
Temperature range−20 to 55 °C
Reporting interval1 min to 1 h, configurable
Telemetry4G, LoRaWAN or NB-IoT
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: US EPA 40 CFR Part 58 Appendix A, EN 14212, EN 14211

What is the Micro Air Quality Monitoring Station?

A compact sensor node that measures several pollutants and reports high-density indicative data. It is the right choice for dense networks, community monitoring and hotspot mapping where many low-cost points are more useful than a few reference stations.

What is the Micro Air Quality Monitoring Station?

A compact sensor node that measures several pollutants and reports high-density indicative data. It is the right choice for dense networks, community monitoring and hotspot mapping where many low-cost points are more useful than a few reference stations.

Overview

The micro station houses electrochemical gas sensors, an optical particle sensor, a temperature and humidity probe and a small data module in a weatherproof enclosure. It measures sulfur dioxide, nitrogen dioxide, ozone, carbon monoxide, PM10 and PM2.5, and reports through 4G or LoRaWAN to a cloud platform. Because low-cost sensors drift and are cross-sensitive, the node is field-calibrated against a reference station or a co-located approved monitor, and correction coefficients are applied in firmware or the platform. Power comes from mains, a small solar panel or a battery, and active fan aspiration keeps the particle sensor responsive. Siting must avoid direct exhaust, walls and radiant heat. The main value is spatial coverage: dozens of nodes can reveal street-level, park and industrial gradients that a sparse reference network cannot resolve, and data support indices, alerts and community engagement.

How does it work?

An ambient station brings together several measurement channels on a common sampling manifold and data platform. A glass or PTFE manifold with a blower draws air from an inlet at a defined height, and short lines feed each analyzer so that all channels sample the same air. Reference analyzers for sulfur dioxide, nitrogen oxides, carbon monoxide and ozone, plus a particulate monitor, sit in a temperature-controlled rack. A calibration system with a zero air generator, permeation or gas dilution devices and a dynamic diluter supplies standards to the analyzers on schedule and can be routed through the whole sampling path. A data logger collects results, applies validity flags and averages, and a computer or modem sends data to a central server. Meteorological sensors for wind, temperature, humidity and pressure are often added, and station siting follows guidance on spacing, height and distance from obstructions.

What are the key features?

  • Multi-sensor node reports gases and particles from one compact enclosure.
  • 4G or LoRaWAN telemetry feeds cloud dashboards and alerts.
  • Solar or battery power allows deployment without mains supply.
  • Field correction against a reference station improves accuracy.
  • Fan aspiration keeps the optical particle sensor responsive.
  • Low unit cost supports dense spatial coverage and hotspot mapping.

What are the technical specifications?

A typical micro air quality monitoring station configuration offers measured pollutants of SO2, NO2, O3, CO, PM10, PM2.5, PM measurement of Optical scattering, 0–1000 µg/m³, gas measurement of Electrochemical sensors, ppb level, temperature range of −20 to 55 °C, reporting interval of 1 min to 1 h, configurable and telemetry of 4G, LoRaWAN or NB-IoT. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Micro Air Quality Monitoring Station is used in dense urban air quality networks, community and school monitoring projects, industrial park hotspot mapping and smart city and traffic exposure studies. Across the wider Ambient Air Stations class, laboratories also deploy it for national and municipal air quality networks, industrial park and fence-line monitoring and traffic and roadside exposure assessment.

Which standards and certifications apply?

Relevant standards and methods include US EPA 40 CFR Part 58 Appendix A, EN 14212, EN 14211, EN 14626, ISO 13964, HJ 664 and GB 3095. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Site the inlet according to the applicable guidance, typically 2 to 15 m above ground and away from vents, walls and trees, and document surrounding land use. Keep the manifold and lines clean and free of leaks, and verify sample flow and residence time at each analyzer. Run the calibration system on schedule, including zero, span and multipoint checks, and record all results for audit. Maintain air conditioning so rack temperature stays stable, replace filters and dryers, and check the zero air generator and its consumables. For regulatory networks, conduct periodic independent audits and co-location comparisons, and manage data with documented validity criteria. Protect the station from lightning and ensure uninterruptible power for the analyzers and logger.

How do I select the right Micro Air Quality Monitoring Station?

Select micro stations for high-density indicative coverage and public information, not for regulatory compliance. Co-locate at least one node per cluster with a reference monitor for correction. In an RFQ, specify pollutants, correction strategy, telemetry, power and mounting hardware.

How does it compare with other Ambient Air Stations variants?

Decide first whether regulatory reference data or indicative data is required, because that sets the analyzer class. Regulatory stations use reference or equivalent method instruments, a full calibration system and a shelter with reliable power, while indicative stations can use sensors and compact enclosures for denser coverage. Then match the configuration to the objectives: background, urban, traffic, industrial or roadside. Consider siting requirements, since inlet height, spacing from roads and buildings and freedom from local sources affect data representativeness. Allow space for future channels, confirm power, air conditioning and network connectivity, and plan for calibration gases and their safe storage. For temporary campaigns, a mobile station avoids civil works. Confirm the data platform, reporting protocol and quality assurance plan.

Full specifications

Full specifications
Measured pollutantsSO2, NO2, O3, CO, PM10, PM2.5
PM measurementOptical scattering, 0–1000 µg/m³
Gas measurementElectrochemical sensors, ppb level
Temperature range−20 to 55 °C
Reporting interval1 min to 1 h, configurable
Telemetry4G, LoRaWAN or NB-IoT
Power supplySolar with battery, or 12 VDC
Ingress protectionIP65
Sensor life12–24 months typical
MountingPole or wall bracket
Weight3–8 kg

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Dense urban air quality networks
  • Community and school monitoring projects
  • Industrial park hotspot mapping
  • Smart city and traffic exposure studies

Key features

  • Multi-sensor node reports gases and particles from one compact enclosure.
  • 4G or LoRaWAN telemetry feeds cloud dashboards and alerts.
  • Solar or battery power allows deployment without mains supply.
  • Field correction against a reference station improves accuracy.
  • Fan aspiration keeps the optical particle sensor responsive.
  • Low unit cost supports dense spatial coverage and hotspot mapping.

Frequently asked questions about Micro Air Quality Monitoring Station

No. They give indicative results with lower accuracy and stability, so they supplement rather than replace reference monitoring. Regulatory decisions and limit comparisons require approved reference or equivalent method instruments.

Request a quotation for the Micro Air Quality Monitoring Station

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote