Soil Sample Divider
土壤分样器
- SKU SSP-0002
- Soil Sample Preparation
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Dividing principle | Rotary cone or riffle chutes |
|---|---|
| Feed particle size | Up to 10 mm |
| Sample volume | 0.2–20 L |
| Number of outlets | 2–16 containers |
| Splitting ratio | Equal portions |
| Repeatability | RSD ≤ 2% between portions |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11464 (soil pretreatment), ISO 11465 (dry matter and water), ISO 18400-102 (sampling techniques)
What is the Soil Sample Divider?
A splitter that reduces a dried, ground soil sample into statistically identical subsamples. It is the right choice for laboratories that must routinely reduce large soil samples without segregation bias before analysis.
What is the Soil Sample Divider?
A splitter that reduces a dried, ground soil sample into statistically identical subsamples. It is the right choice for laboratories that must routinely reduce large soil samples without segregation bias before analysis.
Overview
The soil sample divider takes the flowing or falling stream of ground soil and divides it into equal portions, either with a rotating cone and a ring of containers or with a series of alternating chutes. Because each portion receives many small increments from the whole stream, its composition matches the bulk even when particles differ in size or density, and the operation can be repeated to reach the required analytical mass. Dividing is essential before subsampling ground soil, because a scoop from a cone-shaped pile over-represents fine material that flows to the centre. Feed passages must be wide enough for the largest particles to avoid blockage and bias, and the equipment is cleaned between samples. Some dividers accept a vibrating feeder to keep the flow even, and a final retained portion is kept for repeat analysis.
How does it work?
Soil preparation begins with drying and physical reduction. Air-drying at a moderate temperature removes most free water while limiting chemical change, and oven drying at a controlled temperature is used when the dry mass must be determined. Grinding reduces particle size with a ball mill, disc mill, jaw crusher or agate mortar, chosen so that the material of the grinding surfaces does not contaminate the sample for the elements of interest. Homogenising mixes the ground material until composition is uniform, and dividing reduces it by a rotating or riffle splitter so that each subsample matches the bulk. Sieving with a set of certified sieves classifies particles by size, and a two-millimetre sieve is standard for many soil tests, with finer fractions used for total element analysis. Moisture, contamination and heat are the main risks to control throughout.
What are the key features?
- Rotary or riffle splitting into equal portions.
- Each subsample is statistically identical to the bulk.
- Repeated splitting reaches the required analytical mass.
- Vibrating feeder option keeps the flow even.
- Wide passages accept coarse material without blocking.
- Easy cleaning prevents carry-over.
What are the technical specifications?
A typical soil sample divider configuration offers dividing principle of Rotary cone or riffle chutes, feed particle size of Up to 10 mm, sample volume of 0.2–20 L, number of outlets of 2–16 containers, splitting ratio of Equal portions and repeatability of RSD ≤ 2% between portions. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Soil Sample Divider is used in soil sample reduction before analysis, trace element subsample preparation, retained sample splitting and geochemical survey sample handling. Across the wider Soil Sample Preparation class, laboratories also deploy it for soil chemical analysis preparation, trace metal and geochemical testing and organic contaminant sample preparation.
Which standards and certifications apply?
Relevant standards and methods include ISO 11464 (soil pretreatment), ISO 11465 (dry matter and water), ISO 18400-102 (sampling techniques), EN 16179 (sample pretreatment) and GB/T 32722 (soil pretreatment). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Air-dry samples in a clean, dust-free area away from exhaust and solvent sources, spread thinly and turn them so drying is even, and record the drying conditions. Dry soil gains or loses water readily, so weigh promptly and store prepared samples in sealed containers. Clean mills, mortars and sieves between samples, and run an inert blank through the mill to detect contamination, especially when switching between samples of very different composition. Track and minimise the fine fraction lost as dust during grinding, because it may differ in composition from the bulk. Verify grind quality by sieving a subsample, and record the sieve and mill settings, particle size and operator with each batch. Keep grinding short or cooled to avoid heating that alters organic matter and volatiles.
How do I select the right Soil Sample Divider?
Select the divider whenever ground soil must be reduced to an analytical mass without bias, and choose a rotary type for larger volumes and a riffle type for small or delicate samples. For coarse or sticky material, check passage width first. In an RFQ, specify feed size, sample volume and required subsample mass.
How does it compare with other Soil Sample Preparation variants?
Start from the analysis and the elements of interest. For trace metal work, use grinding surfaces that will not contribute the measured elements, such as agate, zirconia or tungsten carbide, and avoid ordinary steel. For organic contaminant analysis, avoid heat and contamination from lubricants, and consider cryogenic grinding. Choose drying conditions to match the method: air-drying for most chemical tests, controlled oven drying when the dry mass is required, and freeze drying for volatile compounds. Match the mill and sieve to the required final particle size, and add a divider so ground material can be reduced without segregation. Check that the equipment can be cleaned between samples to prevent carry-over, and consider throughput, dust control and the balance and sieves needed to complete the method.
Full specifications
| Dividing principle | Rotary cone or riffle chutes |
|---|---|
| Feed particle size | Up to 10 mm |
| Sample volume | 0.2–20 L |
| Number of outlets | 2–16 containers |
| Splitting ratio | Equal portions |
| Repeatability | RSD ≤ 2% between portions |
| Feed option | Vibrating feeder |
| Materials | Stainless steel or inert plastic |
| Power supply | 220 VAC (vibrating models) |
| Operating temperature | 5–40 °C |
| Cleaning | Brush and air accessible |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Soil sample reduction before analysis
- Trace element subsample preparation
- Retained sample splitting
- Geochemical survey sample handling
Key features
- Rotary or riffle splitting into equal portions.
- Each subsample is statistically identical to the bulk.
- Repeated splitting reaches the required analytical mass.
- Vibrating feeder option keeps the flow even.
- Wide passages accept coarse material without blocking.
- Easy cleaning prevents carry-over.
Frequently asked questions about Soil Sample Divider
Ground soil segregates, with fine material collecting at the centre and coarse particles at the edge, so a scoop can differ markedly from the bulk. The divider takes increments from the whole stream, so each portion matches the sample better.
Divide a sample into portions and measure a sensitive property, such as mass loss on drying or a trace element, in each. Portions should agree within the expected repeatability, so large differences indicate wear, blockage or improper feeding.
Poorly. Moist soil bridges and sticks, biasing the split, so samples are air-dried first. If moist material must be handled, pre-crush lumps and feed slowly, and expect a wider spread between portions.
Air-drying at moderate temperature removes most free water with minimal change to organic matter, carbonates and exchangeable ions, so results reflect the field soil. Oven drying is used when the dry mass must be measured, but higher temperatures can alter some constituents.
Match the material to the analysis: agate or zirconia for trace metals to avoid contamination, tungsten carbide for hard samples, and steel for routine physical work. Ordinary steel introduces iron, chromium and nickel and is unsuitable for metal analysis.
A blank of inert material run through the mill reveals contamination from previous samples or from wearing grinding surfaces. This is especially important when samples of very different composition follow one another, such as a metal-rich ore after a clean soil.
Related models