

Soil pH and Conductivity Meter
土壤 pH 和电导率仪
- SKU SPM-0004
- Soil pH Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| pH range | 0–14 |
|---|---|
| pH accuracy | ±0.01–0.02 |
| Conductivity range | 0–200 mS/cm |
| Conductivity accuracy | ±1% of reading |
| Cell constant | 1.0 cm⁻¹ (typical) |
| Temperature compensation | Automatic, to 25 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 10390 (soil pH), ISO 11265 (electrical conductivity), ASTM D4972 (pH of soils)
What is the Soil pH and Conductivity Meter?
A meter that measures both soil pH and electrical conductivity, usually in the same suspension. It is the right choice for salinity and acidity assessment, such as in greenhouse and salt-affected soils.
What is the Soil pH and Conductivity Meter?
A meter that measures both soil pH and electrical conductivity, usually in the same suspension. It is the right choice for salinity and acidity assessment, such as in greenhouse and salt-affected soils.
Overview
The combined meter uses a pH electrode and a conductivity cell, either in one instrument with two inputs or in a single probe, to measure acidity and soluble salts in the same soil suspension. Because salinity and pH interact and both affect nutrient availability, measuring them together gives a fuller picture: high salinity reduces water uptake and can change the apparent pH, and liming alters both. The conductivity reading is affected by the soil to water ratio and temperature, so a one to five ratio and temperature compensation to 25 °C are used, and results are reported in decisiemens per metre or microsiemens per centimetre. Calibration uses pH buffers and a potassium chloride conductivity standard, and the conductivity cell must be cleaned of soil and organic films, which otherwise reduce the reading. The instrument suits greenhouse, salinity and irrigation water studies.
How does it work?
A soil pH meter measures the activity of hydrogen ions with a glass electrode and a reference electrode, generating a voltage that is converted to pH units. In the laboratory, the method mixes air-dried soil with water or a dilute salt solution such as potassium chloride or calcium chloride at a fixed ratio, most commonly one to five, then stirs and measures after equilibration. The salt solution gives a value closer to the field pH and reduces the effect of soluble salts, while the water method gives a higher reading. Direct-insertion meters use a sturdy electrode pushed into moist soil, which is convenient for field mapping but can be affected by contact and moisture. All electrodes must be calibrated with buffers that bracket the expected range, and temperature compensation corrects for the effect of temperature on the electrode response.
What are the key features?
- Measures pH and conductivity in the same suspension.
- Combined assessment of acidity and salinity.
- Temperature compensation to 25 °C for conductivity.
- Dual or single probe formats suit different workflows.
- Calibration with pH buffers and KCl standards.
- Suits greenhouse, salinity and irrigation studies.
What are the technical specifications?
A typical soil ph and conductivity meter configuration offers pH range of 0–14, pH accuracy of ±0.01–0.02, conductivity range of 0–200 mS/cm, conductivity accuracy of ±1% of reading, cell constant of 1.0 cm⁻¹ (typical) and temperature compensation of Automatic, to 25 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Soil pH and Conductivity Meter is used in greenhouse and potting media testing, salt-affected soil assessment, irrigation water and soil salinity studies and soil reclamation monitoring. Across the wider Soil pH Meters class, laboratories also deploy it for lime requirement assessment, soil fertility and nutrient availability evaluation and soil survey and mapping.
Which standards and certifications apply?
Relevant standards and methods include ISO 10390 (soil pH), ISO 11265 (electrical conductivity), ASTM D4972 (pH of soils), US EPA Method 9045D and ISO 3696 (laboratory water). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate with fresh buffers at two or three points that bracket the sample range, and record the slope, because a slow or low slope indicates an aging electrode. Keep the reference junction wet and clean, since drying and salt deposits cause drift, and store the electrode in the recommended solution rather than in water. Use air-dried soil and consistent mixing, stirring and equilibration, and measure at a controlled temperature. Rinse the electrode between samples and blot, not wipe, to avoid static charge. For direct insertion, choose moist, representative soil and average several readings, and do not rely on field values for lime recommendations without confirming against the laboratory method. Replace electrodes on schedule and maintain buffers within their shelf life.
How do I select the right Soil pH and Conductivity Meter?
Select the combined meter when both acidity and salinity must be assessed, as in greenhouses, saline soils and irrigation studies, since the two parameters interact. For pure pH work, a dedicated pH meter may be simpler. In an RFQ, specify conductivity range, cell type and whether the same suspension is used for both readings.
How does it compare with other Soil pH Meters variants?
Choose the measurement approach first: laboratory suspensions for reported values and comparisons, or direct insertion for rapid field mapping. Laboratory work needs a meter with good resolution and a stable reference, plus the specified salt solution or water and a defined soil to solution ratio, because the ratio and electrolyte change the result by up to a unit. For field use, a rugged portable meter with a spear electrode is convenient, but confirm whether the reading is comparable with laboratory values or is only for relative mapping. If salinity is also of interest, a combined pH and conductivity meter saves time. Consider electrode type and replacement, temperature compensation, buffer and storage solutions, and calibration frequency. For any reported or contractual result, follow the standard method exactly, including the equilibration time.
Full specifications
| pH range | 0–14 |
|---|---|
| pH accuracy | ±0.01–0.02 |
| Conductivity range | 0–200 mS/cm |
| Conductivity accuracy | ±1% of reading |
| Cell constant | 1.0 cm⁻¹ (typical) |
| Temperature compensation | Automatic, to 25 °C |
| Soil to water ratio | 1:5 standard |
| Data memory | Up to 1000 records |
| Outputs | USB or RS-232 |
| Power supply | Rechargeable battery or mains |
| Operating temperature | 0–50 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Greenhouse and potting media testing
- Salt-affected soil assessment
- Irrigation water and soil salinity studies
- Soil reclamation monitoring
Key features
- Measures pH and conductivity in the same suspension.
- Combined assessment of acidity and salinity.
- Temperature compensation to 25 °C for conductivity.
- Dual or single probe formats suit different workflows.
- Calibration with pH buffers and KCl standards.
- Suits greenhouse, salinity and irrigation studies.
Frequently asked questions about Soil pH and Conductivity Meter
Electrolytic conductivity rises strongly with temperature, about two percent per degree for many solutions, so values are compensated to a reference temperature such as 25 °C. Without compensation, seasonal and daily temperature changes would dominate the trend.
A one to five soil to water ratio is standard for the saturated and dilute extracts used in many methods, though saturation extracts are also used when field salinity must be estimated. The ratio strongly affects the result, so it must be stated.
Rinse with deionised water after each use and remove soil and organic films with a soft brush or dilute detergent, then rinse well. Contaminated or platinised electrodes read low, so check the cell constant against a standard solution periodically.
Diluting soil with more solution increases the measured pH because dilution reduces the ionic strength and releases more exchangeable hydrogen, and it also reduces the salt effect. Standards fix a ratio, so results are only comparable when the same ratio is used.
The water method gives a higher pH because it measures only the active acidity in a dilute solution. A salt solution such as potassium chloride or calcium chloride releases exchangeable acidity, giving a lower value that better reflects field conditions and is preferred for lime recommendations.
Calibrate before each measurement session and after any electrode cleaning or replacement, using fresh buffers that bracket the expected pH. Daily one-point checks during heavy use confirm stability, and slopes are recorded to detect electrode ageing.
Related models






