跳转到主要内容
Lab Manufacturers China

测汞仪

Mercury Analyzers

MEA · 原子吸收光谱仪 · 6 个型号

作者:Lab Manufacturers China 技术团队最近复核 适用标准:US EPA Method 7473 Mercury in solids and solutions by thermal decomposition, US EPA Method 7470A Mercury in liquid waste by cold vapor AAS, US EPA Method 1631 Mercury in water by oxidation, purge and trap, and CVAFS

参考标准

  • US EPA Method 7473 Mercury in solids and solutions by thermal decomposition
  • US EPA Method 7470A Mercury in liquid waste by cold vapor AAS
  • US EPA Method 1631 Mercury in water by oxidation, purge and trap, and CVAFS
  • ISO 12846 Water quality — Determination of mercury by AAS after enrichment
  • ISO 20552 Workplace air — Determination of mercury vapour by gold amalgamation
  • EN 15852 Stationary source emissions — Determination of total gaseous mercury
  • IEC 61010-1

什么是测汞仪?

测汞仪利用金汞齐化、冷原子吸收或荧光,或直接热分解,测定空气、水、土壤、食品及工业物料中的汞。它服务于环境监测、食品安全、职业卫生和过程控制。

6 个型号 · 测汞仪

以下 6 个型号为当前配置,具体参数以报价单为准。

热分解金汞齐化直接测汞仪

Direct Mercury Analyzer with Thermal Decomposition and Amalgamation

  • MEA-0001
  • 测汞仪
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software compliance (to be confirmed)
测量范围:
0.05–1000 ng
检出限:
0.001 ng absolute
样品类型:
solid, liquid, slurry
样品量:
10–500 mg
测量时间:
approximately 5 min
燃烧温度:
up to 750 °C

直接测汞仪对固体或液体样品进行热分解,并用金捕集汞进行原子检测。它适合无需酸消解的快速食品、土壤和废物检测。

索取报价
查看详情

冷原子吸收测汞仪

Cold Vapor Atomic Absorption Mercury Analyzer

  • MEA-0002
  • 测汞仪
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)
检出限:
0.05–0.5 µg/L
测量范围:
0.1–100 µg/L
波长:
253.7 nm
还原剂:
tin chloride or sodium borohydride
载气:
argon or nitrogen, 200–600 mL/min
吸收池光程:
100–300 mm

冷原子吸收测汞仪将溶液中的汞还原并测量其蒸气的吸收。它是水、消解固体和工业样品中微克/升水平测定的稳健经济选择。

索取报价
查看详情

冷原子荧光测汞仪

Cold Vapor Atomic Fluorescence Mercury Analyzer

  • MEA-0003
  • 测汞仪
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)
检出限:
0.1–1 ng/L in water
测量范围:
0.5–100 ng/L
波长:
253.7 nm excitation and emission
检测:
photomultiplier, right angle
汞齐化:
gold trap
还原剂:
tin chloride or borohydride

冷原子荧光测汞仪在还原和汞齐化后检测汞原子的荧光。它适合超痕量汞,检出限远低于吸收法。

索取报价
查看详情

便携式环境空气汞蒸气分析仪

Portable Mercury Vapor Analyzer for Ambient Air

  • MEA-0004
  • 测汞仪
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Intrinsic safety certification option (to be confirmed)
检出限:
0.1–2 µg/m3
测量范围:
0–2000 µg/m3
检测原理:
gold film or Zeeman UV
响应时间:
1–20 s
采样流量:
0.2–1.0 L/min
电池续航:
8–12 h

便携式环境空气汞蒸气分析仪用电池供电的手持或现场设备测量环境和职业空气中的汞。它适合职业卫生调查、泄漏应急和室内空气筛查。

索取报价
查看详情

连续汞排放监测系统

Continuous Mercury Emission Monitoring System

  • MEA-0005
  • 测汞仪
  • CE (to be confirmed)
  • EN 15267 QAL1 suitability (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
测量范围:
0–100 µg/m3 or higher
检出限:
0.1–1 µg/m3
响应时间:
60–180 s
采样管温度:
120–180 °C
检测原理:
Zeeman AAS, UV or amalgamation
校准:
gas-phase mercury generator

连续汞排放监测系统实时测量工业烟道气中的汞。它用于满足垃圾焚烧、电厂以及水泥或金属设施的排放限值要求。

索取报价
查看详情

金汞齐化水中总汞分析仪

Total Mercury Analyzer for Water with Gold Amalgamation

  • MEA-0006
  • 测汞仪
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software compliance (to be confirmed)
检出限:
0.5–5 ng/L
测量范围:
1–1000 ng/L
样品体积:
10–100 mL
氧化方式:
bromine chloride or UV oxidation
汞齐化:
gold trap
检测器:
cold vapor AAS or AFS

水中总汞分析仪结合氧化、还原、金汞齐化和检测,自动测定水中的总汞。它适合低检出限和高通量的常规水质监测。

索取报价
查看详情

对比测汞仪型号

型号测量范围检出限测量时间汞齐化检测器
热分解金汞齐化直接测汞仪MEA-00010.05–1000 ng0.001 ng absoluteapproximately 5 mingold trapatomic absorption or fluorescence
冷原子吸收测汞仪MEA-00020.1–100 µg/L0.05–0.5 µg/L30–90 s per sample——
冷原子荧光测汞仪MEA-00030.5–100 ng/L0.1–1 ng/L in water3–10 min per samplegold trap—
便携式环境空气汞蒸气分析仪MEA-00040–2000 µg/m30.1–2 µg/m3———
连续汞排放监测系统MEA-00050–100 µg/m3 or higher0.1–1 µg/m3———
金汞齐化水中总汞分析仪MEA-00061–1000 ng/L0.5–5 ng/L3–10 min per samplegold trapcold vapor AAS or AFS

以上数值代表该产品类别的常见水平。最终参数以报价单及随仪器提供的校准文件为准。

测汞仪的工作原理是什么?汞在金属中很特殊,因为它在室温下易挥发并与金形成稳定的汞齐。多数测汞仪利用其中一个或两个特性。在冷原子吸收中,溶液中的汞用氯化亚锡或硼氢化钠还原为元素态,被扫入吸收池,吸收汞灯 253.7 纳米的谱线。冷原子荧光使用相同发生步骤,但在直角方向检测发射光以提高灵敏度。直接测汞仪加热固体或液体样品释放汞,用金汞齐化器捕集,再解吸进入检测器。环境空气和排放监测仪使用金汞齐化或塞曼原子吸收、紫外吸收等光学技术进行连续测量。校准使用有证汞标准品和气相发生器,且所有系统都需严格控制污染,因为汞在实验室中无处不在。## 测汞仪有哪些型号?- 热分解金汞齐化直接测汞仪:直接测汞仪对固体或液体样品进行热分解,并用金捕集汞进行原子检测。- 冷原子吸收测汞仪:冷原子吸收测汞仪将溶液中的汞还原并测量其蒸气的吸收。- 冷原子荧光测汞仪:冷原子荧光测汞仪在还原和汞齐化后检测汞原子的荧光。- 便携式环境空气汞蒸气分析仪:便携式环境空气汞蒸气分析仪用电池供电的手持或现场设备测量环境和职业空气中的汞。- 连续汞排放监测系统:连续汞排放监测系统实时测量工业烟道气中的汞。- 金汞齐化水中总汞分析仪:水中总汞分析仪结合氧化、还原、金汞齐化和检测,自动测定水中的总汞。## 如何选择合适的型号?应根据样品类型和所需检出限选择测汞仪。直接热分解分析仪可在数分钟内处理固体和液体样品,前处理极少且可达低纳克水平,适合食品、土壤和废物检测。冷原子吸收是水和消解样品在微克/升水平上的稳健经济选择。冷原子荧光检出限更低,适合超痕量水体和海水分析。带金膜或塞曼检测的便携式环境空气分析仪用于职业卫生和室内空气调查。连续排放监测仪和带金汞齐化的总汞分析仪安装于工业烟道和工艺物流。请确认测量范围、样品通量、校准方式以及是否强制采用特定法规方法。## 测汞仪用于哪些领域?测汞仪广泛用于鱼类、大米、海产品和食品中汞、饮用水、废水和海水监测、土壤、沉积物和污染场地评估、职业卫生和室内空气汞蒸气调查、工业烟道排放和工艺物流监测、地质和矿业勘探样品。## 适用哪些标准与认证?测汞仪相关工作通常依据 US EPA Method 7473 Mercury in solids and solutions by thermal decomposition、US EPA Method 7470A Mercury in liquid waste by cold vapor AAS、US EPA Method 1631 Mercury in water by oxidation, purge and trap, and CVAFS、ISO 12846 Water quality—Determination of mercury by AAS after enrichment、ISO 20552 Workplace air—Determination of mercury vapour by gold amalgamation、EN 15852 Stationary source emissions—Determination of total gaseous mercury、IEC 61010-1。CE 等仪器认证需按具体配置逐项确认,不作默认承诺。## 采购前需要考虑哪些要点?汞吸入有毒且会在体内蓄积,因此实验室必须控制蒸气暴露、使用通风柜并监测环境空气。污染是持续风险,因为汞存在于试剂、灰尘和先前样品中,因此超纯试剂、专用器皿和严格的空白必不可少。金汞齐化器在回收率下降时需定期清洁或更换。校准标准品和气相发生器必须可溯源,还原剂须现配。253.7 纳米谱线的光源和检测器需要稳定温度。对排放和环境监测仪,采样管路必须加热且惰性,以防汞损失。保存维修记录,并遵守当地职业接触限值和废物处置规定。

关于测汞仪的常见问题

汞蒸气在室温下与金形成稳定汞齐,加热金时汞又释放出来。将汞捕集在金上可从未经大量样品或气流中富集汞,并与干扰物分离,从而大幅降低检出限。汞齐化器是直接测汞仪和灵敏环境监测仪的核心。

需要协助选型测汞仪?

索取报价